12.07.2015 Views

Boiler Manual - Weil-McLain

Boiler Manual - Weil-McLain

Boiler Manual - Weil-McLain

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GV90+ gas-fired water boiler — <strong>Boiler</strong> <strong>Manual</strong>Dimensions and ratings (continued)Figure 108 <strong>Boiler</strong> dimensional and physical data (see Figure 107, page 100)<strong>Boiler</strong>modelSupply Return LengthLGasconnectionsize (Note 1)Electricalservicerequired(includesthe internalcirculators)<strong>Boiler</strong>watercontentApprox.shippingweight(inches NPTmale)(inches NPTfemale)(inches)(inches NPTfemale)(amperes) (gallons) (pounds)GV90+3 1 1 30¾ ½ 15 3.8 313GV90+4 1 1 30¾ ½ 15 4.7 353GV90+5 1 1 37¾ ½ 15 6.0 423GV90+6 1 1 37¾ ½ 15 6.9 464Note 1: Gas piping from meter to boiler to be sized per local utility requirements.Figure 109 <strong>Boiler</strong> ratingsDOE<strong>Boiler</strong>modelCSAInputDOEHeatingcapacity(Note 1)Net I=B=Rwaterrating(Note 2)AFUE(Note 1)Vent/combustionair diameter<strong>Boiler</strong>watercontent% Input derate vs vent length(Values shown are at maximum vent/air pipe length)(Note 3)Direct Exhaust VentingDirect Vent VentingMBH MBH MBH % Inches Gallons Natural gas Propane Natural gas PropaneGV90+3 70 65 56 91.9 3" PVC 3.8 up to 0.7% up to 1.4% up to 1.5% up to 2.8%GV90+4 105 97 84 91.2 3" PVC 4.7 up to 1.0% up to 2.2% up to 4.0% up to 5.4%GV90+5 140 130 113 91.4 3" PVC 6.0 up to 4.0% up to 4.0% up to 7.0% up to 8.0%GV90+6 175 161 140 91.0 3" PVC 6.9 up to 4.0% up to 4.5% up to 7.0% up to 10.0%Notes:1. Based on standard test procedures prescribed by the United States Department of Energy. Ratings alsoreferred to as CSA Output. NOTE that only DOE Heating Capacity and AFUE are certified by AHRI. AFUE isalso know as Annual Fuel Utilization Efficiency or Seasonal Efficiency.2. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the buildingand nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowanceof 1.15 and are determined under the provisions governing forced draft boiler-burner units. An additionalallowance should be made for unusual piping and pickup loads.3. All of the boilers will automatically de-rate as vent length increases, due to the pressure loss through the vent.For vent/air pipe lengths less than the maximum, the derate equals the value above times vent length ÷ 100.4. <strong>Boiler</strong>s are tested for 50 PSIG working pressure.5. GV90+ boilers are not available for millivolt systems.Part number 550-142-054/1211 101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!