11.07.2015 Views

THERMOZONE AC 300/ WAC 300 WIRING DIAGRAMS AC301 AND ...

THERMOZONE AC 300/ WAC 300 WIRING DIAGRAMS AC301 AND ...

THERMOZONE AC 300/ WAC 300 WIRING DIAGRAMS AC301 AND ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>THERMOZONE</strong> <strong>AC</strong> <strong>300</strong>/ W<strong>AC</strong> <strong>300</strong><strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>308 <strong>AND</strong> <strong>AC</strong>312High/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic 2-stage heat regulationwith thermostat KRT2800, output selection 0–½–1 output with EV<strong>300</strong><strong>AC</strong>308/3124 5 610 12 13 14L 1 L 2 L 3400V3~/230V3~<strong>AC</strong>308/312<strong>AC</strong>308/312P N 1 2 3 4 5 6 710 12 13 14L 1 L 2 L 3L 1 N (L 2 )230 V~400V3~/230V3~31 32 33 34 35 36 37 38<strong>AC</strong>R3042123HiAGB304,position limitswitchAGB304LoDiff (1-4)K123KRT2800KRT2800,2-stagethermostat5 1<strong>AC</strong>R3042,4-stageregulatorX XX XXX X X X1 2 3 46 2EV<strong>300</strong>X XXO 6 2EV<strong>300</strong>,outputselectorHigh/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic 2-stage heat regulationwith thermostat RTI2s, output selection 0–½–1 output with EV<strong>300</strong><strong>AC</strong>308 /3124 5 610 12 13 14L1 L2 L3400V3~/230V3~<strong>AC</strong>308/312<strong>AC</strong>308 /312P N 1 2 3 4 5 6 710 12 13 14L1 L2 L3L1 N (L 2 )230 V~400V3~/230V3~RTI2,electronic2-stage thermostat31 32 33 34 35 36 37 38<strong>AC</strong>R3042HiLoc˚RTI2AGB304,position limitswitchAGB3041 2 3 4 5 6 7 P NL1 N (L2)230 V~5 1<strong>AC</strong>R3042,4-stage regulatorX XX XXX X X X1 2 3 46 2EV<strong>300</strong>EV<strong>300</strong>,output selectorFrico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.seDesign and specifications are subject to change without notice.75


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>300</strong>/ W<strong>AC</strong> <strong>300</strong><strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>308 <strong>AND</strong> <strong>AC</strong>312Outdoor compensated variable fan speed regulation with FRE6, effect limitation with output selectorEV<strong>300</strong> in effect stages 0-½-1.<strong>AC</strong>308/<strong>AC</strong>312P N 1 2 3 4 5 6 7 8 9 10 12 13 14 L1 L2 L3400V3~/230V3~<strong>AC</strong>308/<strong>AC</strong>312P N 1 2 3 4 5 6 78 910 12 13 14 L1 L2 L3<strong>AC</strong>308-<strong>AC</strong>312400V3~/230V3~c˚3211256FRE6,digitalvariable fan speedregulatorFRE6L N N U TK TK 1 2 5 6 101112 21222324EV<strong>300</strong>X XXO 6 2EV<strong>300</strong>,output selectorL N 1 2230 V~OutdoorsensorRoomthermostatDoor contactFRE6 regulates a maximum of 4 x <strong>AC</strong>308 or 2 x<strong>AC</strong>312.<strong>WIRING</strong> <strong>DIAGRAMS</strong> W<strong>AC</strong>301, W<strong>AC</strong>301V, W<strong>AC</strong>302 <strong>AND</strong> W<strong>AC</strong>302VOutdoor compensated variable fan speed regulation with FRE6SD20, actuator,on/off, 230V~W<strong>AC</strong>301-W<strong>AC</strong>302VW<strong>AC</strong>301-W<strong>AC</strong>302VP N 1 2 3 4 5 6 9P N 1 2 3 4 5 6 9W<strong>AC</strong>301(V)/302(V)TRV/TVV20/25SD20TRV/TVVc˚321FRE6L N N U TK TK 1 2 5 6 101112 21222324FRE6 regulates a maximum of 4 xW<strong>AC</strong>301(V) eller 2 x W<strong>AC</strong>302(V)230 V~FRE6,digitalvariable fan speedregulatorOutdoorsensorRoom Door contactthermostat76Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.seDesign and specifications are subject to change without notice.


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>300</strong>/ W<strong>AC</strong> <strong>300</strong><strong>WIRING</strong> <strong>DIAGRAMS</strong> W<strong>AC</strong>301, W<strong>AC</strong>301V, W<strong>AC</strong>302 <strong>AND</strong> W<strong>AC</strong>302VManual 4-stage fan speed regulation with <strong>AC</strong>R304, start/stop with position limit switch AGB304, automaticheat regulation with thermostat RTE/KRT, actuator SD20 and valve TVV20/25For variable fan speedcontrol, see wiringdiagrams on page 73.M ~c˚ M ~c˚ M ~c˚SD20, actuator,on/off, 230V~PTCW<strong>AC</strong>301(V)/302(V)L NL NLTRV/TVV20/25SD20RTE102,electronicthermostatKRT1900,capillary tubethermostatTRV/TVV12345RTE102123KRT1900P N 1 2 3 4 5 6 7 8 9L1N (L 2 )230 V~AGB304W<strong>AC</strong>301-W<strong>AC</strong>302V2 6 81 3 5 7<strong>AC</strong>R30443210XXX X XX XX X1 3 5 7AGB304,position limitswitch<strong>AC</strong>R304,4-stage regulatorHigh/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic heat regulation withthermostat RTE/KRT, actuator SD20 and valve TVV20/25SD20, actuator,on/off, 230V~TRV/TVV20/25,SD20TRV/TVV12345W<strong>AC</strong>301-W<strong>AC</strong>302VW<strong>AC</strong>301-W<strong>AC</strong>302V4 5 6 9P N 1 2 3 4 5 6 9W<strong>AC</strong>301(V)/302(V)RTE102L 1 N (L 2)230 V~31 32 33 34 35 36 37 38<strong>AC</strong>R3042RTE102,electronicthermostat123KRT1900AGB304<strong>AC</strong>R3042,4-stage regulatorKRT1900,capillary tubethermostatAGB304,position limitswitchX XX XXX X X X1 2 3 4Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.seDesign and specifications are subject to change without notice.77

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!