7. DIAGNOSTIC TEST OPERATION (A, B models) EO18-12003(Revision Date: Jun. 21, 2002)7.4 DIAGNOSTIC TEST PROCEDURE(2) Switch the display in order of “320 * 200 * 256”, “640 * 480 * 16”, and “720 * 400 * 16” by pressing [ENTER]key.(3) When the result of “720 * 400 * 16” is displayed, pressing [ENTER] key will return the display to the mainmenu.7.4.14 RS Scanner TestThe operation of the RS scanner is checked.(1) Select “RS Scanner Test” from the main menu by pressing [1] [4], and [ENTER] key.(2) When the following is displayed, set the COM port number and the type of the scanner, then press [F10] key(functioning as [Start] key).>COM Number (3:COM3, 6:SIO2)............[3]Type (1:HS-380, 2:LS-750, 3:LS-120)....[1]Command File Name......................[TSTSCNR.DAT][Quit] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [Start]NOTES:1. For setting, move the cursor to the parameter to be set by using the arrow keys (↓, ↑) or [ENTER]key, enter setting value, then press the [ENTER] key.2. This program runs according to the following settings.Baud rate: 9 6 0 0 bps7 bit/even/2 stopData transfer mode: Mode 4 (STX/ETX mode)NOTE:For HS-380, the above settings are the default options. For LS-700 and LS-750, the baud rate shouldbe set to 9600 bps.(3) The following message will be displayed. (The following code is example.)Master:F49012345678901F49012345678901OKCount OK = XX NG = 0(4) Pressing [F1] key will terminate this test and restore the display to the main menu.7.4.15 EndThe Diagnostic program is terminated.(1) Select “END” from the main menu by pressing [9], [9], and [ENTER] key. The diagnostic program will be terminatedand the DOS prompt will be displayed.7-16

8. DIAGNOSTIC TEST OPERATION (C model)EO18-12003(Revision Date: Jun. 21, 2002)8.1 LIMITATION8. DIAGNOSTIC TEST OPERATION (C model)This chapter describes the Diagnostic test program provided to check for proper operation of the ST-60’s POS I/Odevices.8.1 LIMITATION(1) Since the system is not included in the Diagnostic Sheet due to a problem of the license, it is necessary to beinstalled on your site.For the installation procedure, refer to Section 8.3 SYSTEM FDK PREPARATION PROCEDURE.(2) The configuration file (CONFIG.SYS) in the Diagnostic Sheet is designed for MS-DOS Version 6.2.The installation of the system in the Diagnostic Sheet must be performed on the machine that MS-DOSVersion 6.2 has been properly installed.8.2 OUTLINEThe diagnostic test program checks the following POS I/O devices of the ST-60.• LAN• BIOS• Date/Time• Keyboard• PS-2 Mouse• USB Mouse• Speaker• VGA• COM, SIO port• LPT1• RJ Printer• Drawer• Memory• NV-RAM• UPS• FDD• HDD• Touch Panel• LIU• Sound• RS Scanner8-1

7. DIAGNOSTIC TEST OPERATION (A, B models) <strong>EO18</strong>-<strong>12003</strong>(Revision Date: Jun. 21, 2002)7.4 DIAGNOSTIC TEST PROCEDURE(2) Switch the display in order of “320 * 200 * 256”, “640 * 480 * 16”, and “720 * 400 * 16” by pressing [ENTER]key.(3) When the result of “720 * 400 * 16” is displayed, pressing [ENTER] key will return the display to the mainmenu.7.4.14 RS Scanner TestThe operation of the RS scanner is checked.(1) Select “RS Scanner Test” from the main menu by pressing [1] [4], and [ENTER] key.(2) When the following is displayed, set the COM port number and the type of the scanner, then press [F10] key(functioning as [Start] key).>COM Number (3:COM3, 6:SIO2)............[3]Type (1:HS-380, 2:LS-750, 3:LS-120)....[1]Command File Name......................[TSTSCNR.DAT][Quit] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [Start]NOTES:1. For setting, move the cursor to the parameter to be set by using the arrow keys (↓, ↑) or [ENTER]key, enter setting value, then press the [ENTER] key.2. This program runs according to the following settings.Baud rate: 9 6 0 0 bps7 bit/even/2 stopData transfer mode: Mode 4 (STX/ETX mode)NOTE:For HS-380, the above settings are the default options. For LS-700 and LS-750, the baud rate shouldbe set to 9600 bps.(3) The following message will be displayed. (The following code is example.)Master:F49012345678901F49012345678901OKCount OK = XX NG = 0(4) Pressing [F1] key will terminate this test and restore the display to the main menu.7.4.15 EndThe Diagnostic program is terminated.(1) Select “END” from the main menu by pressing [9], [9], and [ENTER] key. The diagnostic program will be terminatedand the DOS prompt will be displayed.7-16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!