7. DIAGNOSTIC TEST OPERATION (A, B models) EO18-12003(Revision Date: Jun. 21, 2002)7.4 DIAGNOSTIC TEST PROCEDURE7.4.3 COM SIO TestThe operation of COM and SIO ports of the ST-60 are checked.Before starting the test, connect a loop back connector to the port to be tested.(1) Select “COM SIO Test” from the main menu by pressing [3] and [ENTER] key.(2) When COM or SIO port works properly, “[OK]” will be displayed. If there is any problem, “[NG]” will appear.COM SIO Test Sub MenuDiagnostic ProgramCOM Port Test Menu :1. COM1 [OK]2. COM2 [OK]3. COM3 [OK]4. SIO2 [OK]99. ENDNumber==>_When the following sub menu is displayed, select a port to be tested.(3) Pressing [9], [9], and [ENTER] key will terminate this test and restore the display to the main menu.NOTES:1. The configuration of COM2 and SIO2 ports depends on whether or not the customer’s displayis used.CONNECTOR Display with without Customer’sCustomer’s DisplayA COM 2 SIO 22. The loop back connector should be used at the time of this test performance.DCD 1RXD 2TXD 3DTR 4GND 5DSR 6RTS 7CTS 8RI 9D-Sub 9pin femaleP12V 1RXD 2TXD 3DTR 4GND 5DSR 6RTS 7CTS 8P5V 9D-Sub 9pin male7-4

7. DIAGNOSTIC TEST OPERATION (A, B models) EO18-12003(Revision Date: Jun. 21, 2002)7.4 DIAGNOSTIC TEST PROCEDURE7.4.4 UPS TestThe operation of the built-in UPS is checked.(1) Select “UPS Test” from the main menu by pressing [4] and [ENTER] key.(2) When the following sub menu is displayed, select “UPS ON” by pressing [1] and [ENTER] key.UPS Test Sub MenuDiagnostic ProgramUPS Menu :1. UPS On2. UPS Off99. ENDNumber==>_BATTERY NG OKQC ON OFFPWGOOD ON OFFUPS ON OFFThe built-in UPS will start supplying the power to the ST-60, and then the following is displayed. Make sure thatthe ST-60 is backed up by the UPS even after turning the ST-60 power off.Number==>_BATTERY NG OKQC ON OFFPWGOOD ON OFFUPS ON OFF(3) Select “UPS OFF” from the UPS Test Sub Menu by pressing [2] and [ENTER] key to make sure that the ST-60 turns off.7-5

7. DIAGNOSTIC TEST OPERATION (A, B models) <strong>EO18</strong>-<strong>12003</strong>(Revision Date: Jun. 21, 2002)7.4 DIAGNOSTIC TEST PROCEDURE7.4.3 COM SIO TestThe operation of COM and SIO ports of the ST-60 are checked.Before starting the test, connect a loop back connector to the port to be tested.(1) Select “COM SIO Test” from the main menu by pressing [3] and [ENTER] key.(2) When COM or SIO port works properly, “[OK]” will be displayed. If there is any problem, “[NG]” will appear.COM SIO Test Sub MenuDiagnostic ProgramCOM Port Test Menu :1. COM1 [OK]2. COM2 [OK]3. COM3 [OK]4. SIO2 [OK]99. ENDNumber==>_When the following sub menu is displayed, select a port to be tested.(3) Pressing [9], [9], and [ENTER] key will terminate this test and restore the display to the main menu.NOTES:1. The configuration of COM2 and SIO2 ports depends on whether or not the customer’s displayis used.CONNECTOR Display with without Customer’sCustomer’s DisplayA COM 2 SIO 22. The loop back connector should be used at the time of this test performance.DCD 1RXD 2TXD 3DTR 4GND 5DSR 6RTS 7CTS 8RI 9D-Sub 9pin femaleP12V 1RXD 2TXD 3DTR 4GND 5DSR 6RTS 7CTS 8P5V 9D-Sub 9pin male7-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!