4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-12003(Revision Date: Mar. 16, 2007)4.7 MCR UNIT (MCRST-60-3/5 Series)4.6 PCMCIA (MIFST-60-2 Series)1) Remove the B-3x6 screw to detach the PC Card Cover on the bottom of the terminal, and cut off the PCMCIAblind plate from the bottom cover by using nippers (Refer to Fig.4-14).Cut the PCMCIA Blind Plate B-3x6 ScrewFig. 4-142) Connect the PCMCIA unit to the connector on the TOUCH MAIN PC Board or ST-PGA ENGINE PC Board, andsecure it with the three DSM-3x6 screws (accessory). Then, insert the PC card into the slot of the PCMCIAunit. (Refer to Fig. 4-15)DSM-3x6 Screw PCMCIA UnitDSM-3x6 ScrewFig. 4-153) Return the PC Card Cover.NOTE: Insert the PC card into the innermost of the PCMCIA unit after removing the PC Card Cover.Cable Clamp A00TFTFrameINVERTERPC Board4-5

4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-12003(Revision Date: Mar. 16, 2007)4.7 MCR UNIT (MCRST-60-3/5 Series)4.7 MCR UNIT (MCRST-60-3/5 Series)1) Remove the FIU top cover ass’y. (Refer to Section 3.1.1)2) Attach the cable clamp A to the FIU top cover ass’y. (Refer to Fig.4-16)NOTE: Care must be taken for the location and direction of the cable clamp A.Cable Clamp A00TFTFrameINVERTERPC BoardFig. 4-163) Remove the two DSM-3x6 screws to detach the MCR dummy cover, and secure the TOUCH MCRCNT PCboard and MCR unit with the DSM-3x6 screws. Then, connect the MCR cable to CN1 on the TOUCH MCRCNTPC board, and fix the cable with the cable clamps A and B. This cable clamp A is attached to the FIU topcover ass’y in STEP2) and the cable clamp B has already been attached. (Refer to Fig.4-17)CN1 TOUCH MCRCNT PC BoardMCR UnitDIP SwitchDSM-3x6 ScrewDSM-3x6 ScrewCable Clamp ACN2MCR CableCable Clamp BFig. 4-174-6

4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT <strong>EO18</strong>-<strong>12003</strong>(Revision Date: Mar. 16, 2007)4.7 MCR UNIT (MCRST-60-3/5 Series)4.7 MCR UNIT (MCRST-60-3/5 Series)1) Remove the FIU top cover ass’y. (Refer to Section 3.1.1)2) Attach the cable clamp A to the FIU top cover ass’y. (Refer to Fig.4-16)NOTE: Care must be taken for the location and direction of the cable clamp A.Cable Clamp A00TFTFrameINVERTERPC BoardFig. 4-163) Remove the two DSM-3x6 screws to detach the MCR dummy cover, and secure the TOUCH MCRCNT PCboard and MCR unit with the DSM-3x6 screws. Then, connect the MCR cable to CN1 on the TOUCH MCRCNTPC board, and fix the cable with the cable clamps A and B. This cable clamp A is attached to the FIU topcover ass’y in STEP2) and the cable clamp B has already been attached. (Refer to Fig.4-17)CN1 TOUCH MCRCNT PC BoardMCR UnitDIP SwitchDSM-3x6 ScrewDSM-3x6 ScrewCable Clamp ACN2MCR CableCable Clamp BFig. 4-174-6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!