3. MAIN UNIT REPLACEMENT <strong>EO18</strong>-<strong>12003</strong>(Revision Date: Jun. 21, 2002)3.2 BOTTOM COVER SECTIONC model1) Remove the two DSM-3x8 screws on the bottom of the terminal. (Refer to Fig.3-22)DSM-3x8 screwDSM-3x8 screwFig.3-222) Remove the Touch LVDS Cable from CN4 on the ST-PGA ENGINE PC Board, Earth Plate (refer to Fig. 3-23),and the MCR/HOST cable (when the optional MCR is installed). And then, disconnect the BIU cable from CN14on the ST-PGA ENGINE PC Board (when the customer's display is installed) (refer to Fig. 3-24) and remove theTop Cover by lifting the front side.Touch LVDS Cable Earth Plate CN4MCR/HOST Cable< Front side >Fig. 3-23CN14BIU Unit< Back side >Fig. 3-243-9