8. DIAGNOSTIC TEST OPERATION (C model)<strong>EO18</strong>-<strong>12003</strong>(Revision Date: Jun. 21, 2002)8.4 DIAGNOSTIC OPERATION METHOD8.4.22 RS Scanner TestThe operation of the RS scanner is checked.(1) Select “22. RS Scanner Test” from the Main Menu by pressing [2] [2], and the [ENTER] key.(2) When the following is displayed, set the COM port number and the type of the scanner, then press [F10] key(functioning as [Start] key).>COM Number (3:COM3, 6:SIO2)............[3]Type (1:HS-380, 2:LS-750, 3:LS-120)....[1]Command File Name......................[TSTSCNR.DAT][Quit] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [Start]NOTES: 1. For setting, move the cursor to the parameter to be set by using the arrow keys ([≤] and [¯])or [ENTER] key, enter setting value, then press the [ENTER] key.2. This program runs according to the following settings.Baud rate: 9600 bps7 bit/even/2 stopData transfer mode: Mode 4 (STX/ETX mode)NOTE:For HS-380, the above settings are the default options. For LS-700 and LS-750, the baud rateshould be set to 9600 bps.(3) The following message will be displayed. (The following code is example.)Master:F49012345678901F49012345678901OKCount OK = XX NG = 0(4) Pressing the [F1] key will terminate this test and restore the display to the Main Menu.8-18