8. DIAGNOSTIC TEST OPERATION (C model)EO18-12003(Revision Date: Jun. 21, 2002)8.4 DIAGNOSTIC OPERATION METHOD8.4.20 Touch Panel TestThe operation of the Touch Panel is checked.Before performing the Touch Panel Test, slide the write protection tab of the FDK to the write enable side.(1) Select “20. Touch Panel Test” from the Main Menu by pressing [2] [[0], and the [ENTER] key.(2) When the following sub menu is displayed, select an item. When the Windows ® 2000 supporting modelis used, be sure to select “2. Touch Panel (W2K)”.Diagnostic Program===== Touch Panel Test Menu: =====1. Touch Panel2. Touch Panel (W2K)99. ENDINPUT NO: _(3) When the following is displayed, another press of the [ENTER] key will display “Please Push Left-upperpoint on the display” which allows you to designate the touch panel active area.COM No.= 2 IRQ No.= 3 Port Address = 2F8TTAB.EXE version 1.01NOTE:The displayed values for COM No., IRQ No., and Port Address are initial settings.If the touch panel’s actual operating environment does not match the displayed values, enter the correctvalues for your environment.Use the [→] and [←] keys to select the item to be corrected, and the [↑] and [↓] keys to enter the values.Standard setting: COM No.= 2 IRQ No. = 3 Port Address = 2F8(4) Designate the active area by touching the screen with your finger in order of upper left, upper right, lowerleft, and lower right.(5) When the following display appears, touch any position on the screen with your finger to check that the cursoris displayed where you touched.X = xxxY = xxx[ESC] : Exit[SPACE] : Clear Display[ESC] Key:[SPACE] Key:Terminates this test and restores the display to the main menu.Clears the display. (The touch panel test can be resumed.)(6) Pressing the [ESC] key while the above screen is displayed will restore the display to the Main Menu.8-16
8. DIAGNOSTIC TEST OPERATION (C model)EO18-12003(Revision Date: Jun. 21, 2002)8.4 DIAGNOSTIC OPERATION METHOD8.4.21 LIU TestThe operation of the Line Indicator Unit (LIU), i.e., Customer’s Display connected to the ST-60 is checked.This test is applicable to the LIUST-51, 52 and 53 series.NOTE:Be sure to connect the LIU to COM 3 or SIO2 port of the ST-60 before performing this test.(1) Select “21. LIU Test” from the Main Menu by pressing [2] [1], and the [ENTER] key.(2) The following menu is displayed. Select the port to which the LIU is connected by pressing [1] (COM3) or[2] (SIO2) and the [ENTER] keys.===== LIU Test Menu: =====1. COM32. SIO299. ENDINPUT NO.:The LIU will display the LIU type and test data.Sample display (In case of LIUST-51/52)L I U S T - 5 1 / 5 2 T E S T 1 2 3 45 6 7 8 9 0 A B C D E F G H I J K L M N(3) Pressing any key while the display shows “LIU Check. Type any key!!” will terminate this test and restore thedisplay to the LIU Test Sub Menu. At the same time, the LIU type and test data on the LIU will disappear.(4) Pressing [9] [9], and the [ENTER] key will terminate this test and restore the display to the Main Menu.8-17
- Page 51 and 52: 5. ST-60 BIOS SETUP (A, B models) E
- Page 53 and 54: 5. ST-60 BIOS SETUP (A, B models) E
- Page 55 and 56: 5. ST-60 BIOS SETUP (A, B models) E
- Page 57 and 58: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 59 and 60: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 61 and 62: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 63 and 64: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 65 and 66: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 67 and 68: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 69 and 70: 6. ST-60 BIOS SETUP (C model)EO18-1
- Page 71 and 72: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 73 and 74: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 75 and 76: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 77 and 78: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 79 and 80: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 81 and 82: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 83 and 84: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 85 and 86: 7. DIAGNOSTIC TEST OPERATION (A, B
- Page 87 and 88: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 89 and 90: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 91 and 92: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 93 and 94: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 95 and 96: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 97 and 98: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 99 and 100: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 101: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 105 and 106: 8. DIAGNOSTIC TEST OPERATION (C mod
- Page 107: 10. PERIODICAL MAINTENANCE EO18-120
8. DIAGNOSTIC TEST OPERATION (C model)<strong>EO18</strong>-<strong>12003</strong>(Revision Date: Jun. 21, 2002)8.4 DIAGNOSTIC OPERATION METHOD8.4.21 LIU TestThe operation of the Line Indicator Unit (LIU), i.e., Customer’s Display connected to the ST-60 is checked.This test is applicable to the LIUST-51, 52 and 53 series.NOTE:Be sure to connect the LIU to COM 3 or SIO2 port of the ST-60 before performing this test.(1) Select “21. LIU Test” from the Main Menu by pressing [2] [1], and the [ENTER] key.(2) The following menu is displayed. Select the port to which the LIU is connected by pressing [1] (COM3) or[2] (SIO2) and the [ENTER] keys.===== LIU Test Menu: =====1. COM32. SIO299. ENDINPUT NO.:The LIU will display the LIU type and test data.Sample display (In case of LIUST-51/52)L I U S T - 5 1 / 5 2 T E S T 1 2 3 45 6 7 8 9 0 A B C D E F G H I J K L M N(3) Pressing any key while the display shows “LIU Check. Type any key!!” will terminate this test and restore thedisplay to the LIU Test Sub Menu. At the same time, the LIU type and test data on the LIU will disappear.(4) Pressing [9] [9], and the [ENTER] key will terminate this test and restore the display to the Main Menu.8-17