11.07.2015 Views

Leviton Catalog - Womack Electric Supply Company

Leviton Catalog - Womack Electric Supply Company

Leviton Catalog - Womack Electric Supply Company

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OCCUPANCY SENSOR POWER PACKSCommercial Grade Energy Management ProductsOccupancy Sensor Power PacksPower packs provide power for occupancy sensors as well as load switching circuitry. A <strong>Leviton</strong> Power Pack isrequired with any low voltage occupancy sensor. Add-A-Relay units can be used to expand control capability.Power Packs and Accessories UR(For use with <strong>Leviton</strong> Occupancy Sensors on pages D6–D10)DESCRIPTION CAT. NO. POWER RELAY RATING CONTROL POWER SUPPLYINPUT INPUT OUTPUTPower Pack OSP20-0D0 120/220/ 20A fluorescent/ 5mA, 150mA,277VAC, incandescent @ 120V, 24VDC 24VDC60Hz 20A fluor. @ 277V;1HP @120V,2HP @ 240VPower Pack with OSP20-RD0 120/220/ 20A fluorescent/ 5mA, 150mA,HVAC relay 277VAC, incandescent @ 120V, 24VDC 24VDC60Hz 20A fluor. @ 277V;1HP @ 120V, 2HP @ 240V;HVAC: 0.5A @ 125VAC,1A @ 30VDCPower Pack with OSP15-R30 347VAC, 15A fluorescent @ 347V; 5mA, 120mA,HVAC relay 60Hz 1HP @ 120V, 2HP @ 240V; 24VDC 24VDCHVAC: 0.5A @ 125VAC,1A @ 30VDCAdd-A-Relay Unit OSA20-R00 — 15A incandescent @120V, 5mA, —with HVAC relay 20A fluorescent @120V, 24VDC20A fluor. @ 277V,15A fluor. @ 347V;HVAC: 0.5A @ 125VAC,1A @ 30VDCLow-Voltage Nipple OSPNA-000Adapter with 1 /2"Lock Nut for PowerPack andAdd-A-Relay unitsPower Pack Capacity Formula<strong>Leviton</strong> power packs can be used to provide power to one or more occupancy sensors. Since currentconsumptions of occupancy sensors may vary, the best way to ensure you order the correct number ofpower packs and Add-A-Relays is by using this formula:Number ofModel A sensorsXSensor A currentconsumption ratingNumber ofModel B sensors+X+ X < 150mA per power packSensor B currentconsumption rating…SENSOROSC04-I, OSC15-I, OSWHB-I, OSWLR-I, OSWWV-IOSC05-M, OSC05-U, OSW12-MOSC20-M, OSC20-UOSC10-M, OSC10-UOSA20-R00 Add-A-RelayNumber ofAdd-A-Relays50mACURRENT CONSUMPTION20mA30mA32mA40mA50mA3.66 (93.0)OSP20-RD01.38(35.1)2.35 (56.7)Energy Management ProductsSPECIFICATIONS AND FEATURESPower Pack• For use with all OS Series occupancy sensors• Power supply for OS Series occupancy sensors• Switches incandescent, magnetic and electronicfluorescent, magnetic and electronic low voltage,and motor loads• Compact size and light weight allows easy mountingthrough knockout in junction box (from eitherinside or outside the box) with a simple twist-on nutAdd-A-Relay• Expands power pack load capacity by functioningas a supplementary relay• Provides ability to switch loads in different voltagesystems• Compatible with electronic ballasts• Same compact size and mounting features asPower PackNipple Adapter• Simplifies the connection of occupancy sensor tothe low-voltage side of a power pack mountedinside a fluorescent ballast cavity• 1 /2" conduit lock nut includedTESTING & CODE COMPLIANCE• cULus, FCC and NOM Certified• Meets ASHRAE Standard 90.1 requirements• Backed by a Limited Five-Year WarrantyFor answers to technical questions, call <strong>Leviton</strong>’s Techline at 1-800-824-3005D11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!