11.07.2015 Views

Leviton Catalog - Womack Electric Supply Company

Leviton Catalog - Womack Electric Supply Company

Leviton Catalog - Womack Electric Supply Company

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TECHNICAL INFORMATIONIndustrial Grade Watertight Safety Disconnect Switches2 YEAR LIMITEDby <strong>Leviton</strong>Meets 2002 NEC ®Requirements430.102 (A) and430.102 (B)Engineered to UL & IECWatertight StandardsAMPSCurrentInterruptingEnduranceDielectricDS30-AXEngineered to IP65Water Jetting StandardsOrdering Information for Watertight Safety Disconnect SwitchesGroundPathIntegrityMAXVOLTAGEINTERUPTED RATINGS — RMS SYMMETTRICAL AMPERESCATALOG NO. NON-FUSEDCATALOG NO. FUSED30 600V AC DS30-AX DS30-FAX60 600V AC DS60-AX DS60-FAX100 600V AC DS100-AX —ELECTRICALDevice Current DurationApplied30 A 60 A 2 min60 A 120 A 4 min100 A 200 A 6 minCertified forcurrentinterrupting atfull-ratedcurrent andvoltage6000 operationsat ratedcurrent andvoltage(Power factor0.75 – 0.80)1000 V plustwice ratedvoltage for1 minuteMAX. HP RATINGS PER UL508VOLTSNON-FUSED SAFETY DISCONNECT SWITCHESDS30-AX DS60-AX DS100-AX120V AC 1 2 5208V AC 5 20 25240V AC 2.5 10 15480V AC 5 20 25600V AC NA 20 203Ø Y 120/208V AC 5 20 253Ø 240V AC 5 20 303Ø 480V AC 15 40 503Ø 600V AC 15 40 50NR = Not Rated NA = Not AvailableMECHANICALMold Stress Relief 70°C for 7 hoursRemains in placeKnockout Test with 20 lbpushCrushImpactCold ImpactStrength ofInsulatingBase and SupportPulloutDS60-FAX(Fused)Non-Fused are suitable for use on circuits capable of deliveringnot more than (see chart below for catalog no. and value)RMS symmetrical amperes.100 lb1.2 lb steel balldroppedfrom 5 ftSame asabove, afterconditioningto -35°C110% ofspecifiedtighteningtorque onterminal screws18 lb pull oninternal wiresDS100-AX(Non-Fused)Fused, when protected by Class J fuses, 600V AC maximum,are suitable for use on circuits capable of delivering not morethan (see chart below for catalog no. and value)RMS symmetrical amperes.ENVIRONMENTALV2 or better perUL 94 or CSAFlammability 22.2 No 0.6;V-0 for watertightenclosureRain (3R)Water spray @per UL 505 psi fromall sides for 1 hrHosedown (4X)Water spray @per UL 5065 gal/min for5 minutesCement DustDust (12K)Circulated @per UL 501000 ft/minute for5 minutesGasket Aging70°C for168 hoursExposed plasticUV Resistance materialsare UV stabilizedOperating-40°C to +60°CTemperature(-40°F to +140°F)MAX. HP RATINGS PER UL508VOLTSFUSED SAFETY DISCONNECT SWITCHESDS30-FAXDS60-FAX120V AC 2 NR208V AC 7.5 15240V AC 3 NR480V AC 15 NR600V AC 20 NR3Ø Y 120/208V AC 7.5 153Ø 240V AC 7.5 153Ø 480V AC 15 303Ø 600V AC 20 50For answers to technical questions, call <strong>Leviton</strong>’s Techline at 1-800-824-3005Watertight Safety Disconnect SwitchesF9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!