<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong><strong>User</strong> <strong>Manual</strong>Issue B


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BLevel .............................................................................................................................................................22SCHEDULE.........................................................................................................................................................22LOCKOUT (<strong>PX</strong> ONLY)........................................................................................................................................23EXPIRY DATE (<strong>PX</strong> ONLY)..................................................................................................................................23TEL NUMBER ...................................................................................................................................................23LOGS...................................................................................................................................................................24TIME ...................................................................................................................................................................24HOLIDAY...........................................................................................................................................................25SCHEDULE ........................................................................................................................................................25GROUP TEXT....................................................................................................................................................25MINUTES LEFT (<strong>PX</strong>250HS ONLY) ...............................................................................................................26LATE WORK .....................................................................................................................................................26BYPASS...............................................................................................................................................................27CHIME................................................................................................................................................................27SHUNT ................................................................................................................................................................28PRINT TEXT......................................................................................................................................................28PRINT HOLS......................................................................................................................................................28IDENTIFY USER...............................................................................................................................................28COPY USER .......................................................................................................................................................29COPY A/USER (<strong>PX</strong> ONLY)..............................................................................................................................29CCT STATUS .....................................................................................................................................................29ACCESS FEATURES (<strong>PX</strong> ONLY) ..................................................................................................................30ADD A/USER......................................................................................................................................................30DELETE USER ..................................................................................................................................................31DOOR UNLOCK................................................................................................................................................31DOOR LOCKOUT.............................................................................................................................................32ACM TEXT.........................................................................................................................................................32APPENDIX A – USER AUTHORITIES..........................................................................................................33APPENDIX B – EDITING TEXT.....................................................................................................................34APPENDIX C - LOG MESSAGES...................................................................................................................35APPENDIX C – ACCESS LOG MESSAGES .................................................................................................38APPENDIX E - MENU RESTRICTIONS .......................................................................................................39- 3 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAPPENDIX E - LOG ON MESSAGES............................................................................................................40APPENDIX F – AUDIO COMMANDS ...........................................................................................................41APPENDIX G - SYSTEM DETAILS ...............................................................................................................42KEYPADS...........................................................................................................................................................42SET GROUPS ......................................................................................................................................................42CIRCUITS ...........................................................................................................................................................43USERS................................................................................................................................................................44- 4 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BIntroductionThe <strong>PX</strong> Electronic Intruder Alarm System is designed to provide secure protection for the installation.The system comprises a main control panel, normally located out of sight in a secure area, and atleast one keypad. The panel has a wide range of features, which are programmed by the engineer oninstallation, to suit the security requirements of the particular installation. Some of the features may bereprogrammed, edited, or viewed as required by an authorised user.Feature <strong>RX</strong>16i <strong>QX</strong>32i <strong>PX</strong>48i <strong>PX</strong>80i <strong>PX</strong>500 <strong>PX</strong>250HSMax. Panel <strong>User</strong>s 32 32 50 100 200 200Max. Access <strong>User</strong>s 1000 1000 1000 1000Areas 4 8 8 16 32 16Set Groups 8 8 16 32 16Sub systems 4 4 8 16 8Max Keypads 4 8 8 16 32 16Access Modules 32 32 32 32Audio Modules 2 4 8 16 32 16Radio Modules 2 2 4 8 16 8Max. Transmitters 16 16 24 40 128 128Tel Numbers 8 8 8 8 8 8Schedules 2 4 32 32 32 32Holidays 14 14 14 14 20Event Log Size 250 500 1000 1000 1000 2000Access Log Size 1000 1000 1000 1000Event LogThe event log will record all events, for example, user log-on times and user numbers, keypadnumbers, setting and unsetting times, alterations made to programmed settings, fault conditions, etc.When the event log is full, the oldest event will be automatically removed when the next event occurs.All log events are date and time stamped and may be viewed, or printed if a printer is fitted to thesystem.Areas & Set GroupsFor protection purposes, the premises may be divided into a number of areas. Individual areas maybe grouped together into a setting group (Not <strong>RX</strong>16i) which provides the user with a convenient wayof setting and unsetting more than one area at the same time. The installation company engineer willhave configured your system for the appropriate number of areas and groups to comply with yourspecific security requirements. Where more than one group is incorporated in the system, a groupcan be configured by the installation engineer as a common group. A common group willautomatically set if all other areas of the system are set and will automatically unset if any one of theother areas is unset. The <strong>RX</strong>16i variant does not include the set group feature. If using a <strong>RX</strong>16i thenall references to set groups throughout this manual should be interpreted as areas.CircuitsEach detector or sensor in the installation is allocated a unique circuit number. The installationengineer will have programmed each circuit to respond in a certain way when the circuit is activated,when the area is set and unset. The way in which the circuit is programmed to respond will depend onthe type of circuit and its location and purpose. If a circuit is faulty, the alarm response may be turnedoff by an authorised user. This process is referred to as bypassing.<strong>User</strong>, Set group and Circuit IdentificationEach user, set group, circuit, concentrator and access control module can be programmed with a textdescription.- 5 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BEasy SetIf your system is programmed with the easy set option then all PIN codes are 4 digits long and PINcodes can be entered without confirming with the button. A card or fob may still be used in place ofa PIN when easy set is programmed.HelpWhen the main user menu is on display press the help button (?) to display information about thesystem. There are 3 options.OptionAssistContractProduct InfoDescriptionSelect to connect to a remote service operator. Your alarm company may notsupport this feature.The customer contract number is a 6-digit number programmed by theinstallation engineer that uniquely identifies your system.The product info option displays the control panel order code and firmwareversion number and, if fitted the Dialler version number.An authorised user can change some of the system parameters. When changing an item the helpbutton can be used to display the allowed values.Remote AssistBefore using the remote assist option you must obtain a number from your alarm company. When youneed to use the remote service, you will be prompted to enter this number, and the panel will dial thealarm company. The alarm company will then be able to check the condition of your system andidentify and resolve problems.02=Set04=TestAssistNumber _?0=Assist1=Contract2=Product Info01Assist-1=DialService not availableonentered number12:00 Mon 27 Sep<strong>Guardall</strong>You will now be logged off andthe system will now connect tothe remote service centre.- 8 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BIncorrect CodesIf Easy Set is not programmed and an incorrect user code is entered, the incorrect code message willbe displayed for a few seconds or until another key is pressed. The installation engineer will haveprogrammed a limit on the number of incorrect code attempts that can be made. If more than theprogrammed number of code attempts are made to enter a valid user code, the keypad will be lockedout and the display will show Out of Service for a period of 5 minutes. Any attempt to enter a usercode during the locked out period will extend the period by another 5 minutes.12:00 Mon 27 Sep<strong>Guardall</strong>2 0 2 0 5 Min.Delay12:00 Mon 27 SepEnter- ****12:00 Mon 27 SepIncorrect CodeMaximum Codeattempts12:00 Mon 27 SepOut Of Service- 9 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BSetCode-02The system can be partitioned into a number of parts called set groups, each of which can beindividually set. The programmed user authority level must allow setting and the programmed userarea access will determine which set groups are available to a user.Setting can be started by:1. A user request on a keypad2. A user activating a keyswitch or radio Keyfob3. Automatically by a timer schedule4. Remotely from a PC using the <strong>Guardall</strong> GuardStation software5. A user request on an ACM Proximity Reader.Setting modes include:1. Instant, where setting is completed immediately2. Timed, where setting is completed at the end of the programmed exit time3. Exit point, where setting is completed by opening and closing the final exit circuit4. Push button, where setting is completed by pushing the external PB circuits after opening andclosing the final exit circuitYour installation engineer should advise which of the above options have been programmed on yoursystem.Setting from a keypad12:00 Mon 27 Sep<strong>Guardall</strong>Log off after setprogrammed0 2 0 2 Log on set programmed, one group available12:00 Mon 27 Sepand no problems or warnings to displayEnter- ****Log on set programmed02=Set04=Test0 21=Workshop2=Office1WorkshopSettingWorkshopSeconds Left-005Log off after setnot programmedExit timeexpiredWorkshopSetSetting with a Mini KeypadThe mini keypad has two quick set buttons. The actual areas or groups controlledby the green and yellow buttons will depend on how the system has beenprogrammed by the installer. The green button will set/unset the first programmed area or setgroup and the yellow buttonwill set/unset the second programmed area or set group. Pressingand holding both and will set the first and second group or area.- 10 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BKeyswitch/Radio Keyfob SettingAs an alternative to setting and unsetting from a keypad, your system may be fitted with an optionalkeyswitch, which permits setting and unsetting of a group by operating a keyswitch. The keyswitchmay be configured for any set mode. If your system is fitted with a radio interface then a radio Keyfobmay be programmed for setting.Automatic SettingThe system may have been programmed by the installation engineer to automatically set all or partsof the system according to a pre-programmed schedule. The schedule will have been programmed totake into account the normal closing time, non-working days and holidays. The schedule may beconfigured for any set mode.Aborting The Setting ProcedureThe setting procedure can be aborted at any time during the exit time by pressing on the keypadthat was used to start setting, logging on to any other keypad, turning a keyswitch to the unsetposition or an appropriate radio Keyfob.Setting with WarningsThe system will automatically display any conditions that the user should be aware of before settingthe system. These conditions are described as set warnings and do not prohibit the user from settingthe system in the normal way.1=Workshop2=Office1Loading DoorIsolated=SetThe set warnings include:1. Bypassed circuit(s)2. Circuit(s) on soak test has failed (a special circuit test mode set upby the installation engineer)3. Isolated circuit(s)4. Line Fault (only when setting with telephone line fault is allowed)5. Shunted circuit(s)6. Battery test faults, when setting is allowed with this type of fault.7. 230v mains faults, when setting is allowed with this type of fault.WorkshopSeconds Left-005Easy SetIf easy set mode 1 is programmed then the system will start to part set when you log on. During thepart set exit time, if the exit door circuit is opened and closed, the system will full set. Pressing thekey during the setting time will cancel setting. If easy set mode 2 is programmed then the systemcan be set without logging on to a keypad. Up to 8 parts can be set in this way (depends on thecontrol panel type). For example to set part 1 of your system from 1 + . The system can be set byentering 0 + .If using a mini keypad then the house symbol buttons can be used to set.+ = set first group or area.+ = set second group or area.and+ = set first and second group or area.- 11 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BSetting Restrictions1. The selected group is programmed with a set level and a lower level set group(s) has not beenset.2. If a user attempts to set a high level set group when a lower level is not set then a warningmessage will be displayed.In a <strong>PX</strong>250HS, there are several additional conditions that apply when setting.1. The keypad may be programmed to disable setting2. The selected group may be programmed for dual user setSetting FaultsIf the group cannot set a message will be displayed. This can occur at the start of setting or at the endof the exit time depending on how your system is set up and when the fault occurs. If a fault occursduring the exit time the exit tone will change to a warning tone. The external sounder may also havebeen programmed by the installation engineer to activate in the event of a failure to set.1=Workshop2=OfficeCannot Set1Cct FaultPIR in Hall=Force SetPIR in HallBypassedAfter the setting fault(s) is displayed the force setoption may be presented (if programmed by theinstallation engineer). The force set option will attemptto automatically bypass all faults. The circuit(s) withthe fault must be programmed by the engineer to allowbypass.=SetWorkshopSeconds Left-005- 12 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BDual Set (<strong>PX</strong>250HS Only)12:00 Mon 27 Sep<strong>Guardall</strong>12:00 Mon 27 SepEnter- ****0 2 0 2 In the example the vault area is programmed for dualuser set. The first user code is 0202 and the seconduser code is 1234. Both users must have the authorityto set the vault area.Both user actions are logged.02=Set04=TestLogon time limit reached021=Vault2=Office1Dual CodeEnter-1 2 3 4 VaultSetting- 13 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BUnsetCode-01The system will have been partitioned by the installation engineer into a number of set groups. Theuser authority will determine the choice of groups, which can be unset. There are several methods ofunsetting available to the user, which are discussed in the following section.Unsetting can be started by:1. A user request on a keypad2. A user activating a keyswitch or radio Keyfob3. Automatically by a timer schedule4. Remotely from a PC using the <strong>Guardall</strong> GuardStation software5. A user request on an ACM Proximity Reader.Your installation engineer should advise which of the above options have been programmed on yoursystem.Unsetting MethodsIf a set group incorporates an entry route in the unsetting procedure then opening a final entry door tothe area will start a pre-programmed entry timer. The user must proceed directly to the keypad orkeyswitch via a pre-determined entry route and unset the group as described. If the group is not unsetbefore the entry time has expired a warning period of 30 seconds will be given. This is to warn theuser that an alarm condition will occur if the group is not unset by the end of the warning period. If thegroup is not unset by the time that the total entry time and warning time has expired, an alarmcondition will be initiated. To comply with the requirements of DD243 (2002), during the entry time, allalarms in the unsetting area(s) are ignored.Unsetting from a keypadYour installer may have set up your system to allow automatic unset when your user code is entered.The diagram shows all 3 possible unset scenarios when a user logs on to a keypad when area(s) areset.12:00 Mon 27 Sep<strong>Guardall</strong>Log off after unset programmed0 2 0 2 12:00 Mon 27 SepEnter- ****Log on unset programmed01=Unset04=Test011=Workshop2=Office1WorkshopUnsetLog off after unset not programmedUnsetting with Keyswitch or Radio KeyfobTo unset an area from a keyswitch, turn the keyswitch to the unset position. The area under thecontrol of the keyswitch will immediately unset. . If your system is fitted with a radio interface then aradio Keyfob may be programmed for setting.- 14 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAutomatic UnsettingThe system may have been programmed by the installation engineer to automatically unset all orparts of the system according to a pre-programmed schedule. The schedule will have beenprogrammed to take into account the normal opening time, non-working days and holidays.Unsetting WarningsWhen unsetting from a keypad, the user is informed on the display of any warnings, e.g. circuitsisolated or on soak. The warning display will appear for approximately 4 seconds during the unsettingprocedure. If more than one warning exists, the display will automatically scroll through the list ofwarnings.WorkshopUnsetPIR in StoreIsolated02=Set04=TestThe unset warnings are:1. Bypassed circuit(s) (the circuit must have a 24hr response)2. Circuit(s) on soak test has failed (a special circuit test mode set up bythe installation engineer)3. Isolated circuit(s)4. Line Fault (only when setting with telephone line fault is allowed)5. Shunted circuit(s)6. Circuit has reached the programmed multiple alarm limit7. Battery test faults8. 230v mains faultsUnsetting RestrictionsThe selected group is programmed with a set level and a higher level set group(s) has not beenunset. If a user attempts to unset a high level set group when a lower level is set then a warningmessage will be displayed.In a <strong>PX</strong>250HS, there are several additional conditions that apply when unsetting.1. The keypad must be programmed by the engineer to allow unset2. The selected group may be programmed for dual user unset3. An open/close schedule may be programmed for the selected group and the time is after theprogrammed close time. This condition may be ignored following an alarm in one of the set groupareas if the set group is programmed with an alarm unset time. In this case, after unsetting, theset group will automatically set after the programmed Alarm Unset period.4. The selected group may be programmed with an Unset Delay time and set group will only unsetat the end of the programmed unset delay period. A message will be displayed during this timeand the user unset request will be logged.5. If a group is manually set before the scheduled set time then it may be unset up to the number ofprogrammed Early Set minutes after the time the group was set.6. The schedule unset option does not apply.- 15 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BUnset Delay (<strong>PX</strong>250HS Only)12:00 Mon 27 Sep<strong>Guardall</strong>12:00 Mon 27 SepEnter- ****0 2 0 2 01=Unset04=Test011=Vault2=Office1In the example the vault area is programmed with anunset delay. The unset delay time is programmed bythe installation engineer.UnsetPlease Wait . . .VaultUnset02=Set04=TestLog off after unsetprogrammed12:00 Mon 27 Sep<strong>Guardall</strong>Dual Unset (<strong>PX</strong>250HS Only)12:00 Mon 27 Sep<strong>Guardall</strong>12:00 Mon 27 SepEnter- ****0 2 0 2 In the example the vault area is programmed for dualuser unset. The first user code is 0202 and the seconduser code is 1234. Both users must have the authorityto unset the vault area.Both user actions are logged in the event log.01=Unset04=TestLogon time limit reached011=Vault2=Office1Dual CodeEnter-1 2 3 4 VaultUnset02=Set04=Test- 16 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BResetCode-03The resetting method programmed by the alarm company engineer for each area and the system willdepend on the particular security requirements of the area or system. There are 3 types of reset:1. Customer reset, where the customer can reset any alarm2. Engineer reset, where the alarm company engineer must reset all alarms3. Managed reset, where the customer can reset an alarm after reporting the event to the alarmcompanyWorkshopUnsetAlarmPIR in Office=ResetAlarm cannot be reset01313333802Code:12345602=Set04=TestIf your system is programmed for engineer reset atelephone number and code will be displayed. Call thisnumber and quote your code. if your system isconfigured for managed reset you will be given a codeto reset your system. This code can only be usedonce.If an engineer or managed reset is required, it will notbe possible to set the system.Managed ResetIf the system is programmed for managed reset and an engineer reset is required contact the alarminstallation company. You will be issued with a special 6-digit PIN code. This PIN code can be usedonly once to reset the system. Logon to the keypad with this PIN code to clear the engineer resetcondition.12:00 Mon 27 Sep<strong>Guardall</strong>reset code + 12:00 Mon 27 SepEnter- *****Reset OK- 17 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BTestCode-04Each area of the system can be tested individually or all areas can be tested at the same time. Thetest time is limited to 1 hour. If the user does not end the test by the end of the test time then the panelwill exit test mode automatically.04=Test 0 4AreaNumber _1=Sounder2=Audio3=Strobe4=Walk Test5=Comms Test6=DetectorEnter the area number,or 0 to test the system12Sounder OnStrobe On3Audio On4PIR in HallNot TestedFront DoorNot TestedWalk TestAll TestedUntested circuitswill be displayedAll circuitstested5Tel Number 1Please Wait . . .AcknowledgereceivedTel Number 2Please Wait . . .All numbersTestedThe panel records all activations from sensors during the unset period. When walk test is selected thepanel will display all circuits which have not alarmed since the panel was last unset. If all circuits are tobe tested then select walk test, then press the button and select walk test a second time. When thepanel exits walk test mode, either manually or automatically at the end of the test time then:1. Any fire sensor still in alarm will give a normal alarm response.2. Circuits with a 24-hour response, which are still in alarm, will be temporarily bypassed.3. A warning will be displayed if any PA sensor is still in alarm.If the comms test is selected then the panel will make a test call to all telephone numbers that havebeen programmed for test by the installation engineer.- 18 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BEngineerCode-05The Eng option will only be available if the system is configured for user authorised engineer access.This option applies to both local and remote engineer access. When the Eng option is selected thesystem will prompt for the engineer PIN code to be entered.05=Engineer0 5Engineer<strong>Guardall</strong>When an engineer logs on to a keypad, all otherkeypads in the system will be inoperable and thedisplay will show Out of Service.or time out (2 minutes)12:00 Mon 27 Sep<strong>Guardall</strong>Once logged on the engineer working time is limited to 8 hours.PINCode-06All users on the system are identified by a 4, 5 or 6-digit PIN code. To change user PIN code, log onto the keypad using your current PIN code and choose the PIN option. Then follow the displayprompts. All user PIN code changes are recorded in the system event log. If the PIN code option isnot available this means that the system has been programmed to prevent you from changing youruser PIN code, and a new PIN code must be allocated by the security system manager. In theexample shown the user changes code to 1234.06=PINPIN OKNew PIN12340 61 2 3 4 PIN notuniqueNew PINNot AvailableIf another user on the system already uses the chosen PIN code then that user will be alerted whennext logging on to the system. The user whose PIN is known must change PIN code to avoid seeingthe warning message on every log on.- 19 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue B<strong>User</strong>Code-07Any master user can change the name, user code and authority for any user except the engineer. Tomodify a user’s details enter the user number in the range 2-max users. In the programming exampleuser 3 is used.07=<strong>User</strong>0 7<strong>User</strong>Number ____3 1=Name2=PIN3=Card4=Authority5=ACM Authority6=Schedule7=Lockout8=Expiry DateThe user 2 configuration may only be changed by user 1 or user 2. Access system users can beadded quickly using the “Add <strong>User</strong>” menu option (50), rather than programming them individually.<strong>User</strong> Menu Name Code-1When the name option is selected the current user descriptor will be displayed and can be edited.Refer to appendix B for details. <strong>User</strong> names can be up to 10 characters long.<strong>User</strong> Menu PIN Code-2For details of changing a code refer to the main menu code change option. The default user codesare shown in the table. The maximum PIN code length is 6 digits.Default Codes<strong>User</strong> NumberPIN2 02023-last user Off1=Name2=PIN2New PIN1234PIN not uniqueNew PINNot Available3=Card4=Authority5=ACM Authority6=Schedule7=Lockout8=Expiry DatePIN OK1 2 3 4 - 20 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue B<strong>User</strong> Menu Card Code-3The procedure for adding a card is similar to adding a new PIN. Present the new card to reader whenprompted to do so. Alternatively, if the card number is known, it can be entered on the keypad. Themaximum number of card digits, excluding the optional site ID, is 8 digits<strong>User</strong> Menu Authority Code-4<strong>User</strong>s can be programmed with a number of options including authority level, group access and timedaccess. The available menu options are dependent on the programmed user authority. Refer to themenus options section for details of the menu options available to each authority levelOption Range DescriptionCode Change On/Off Some user types are allowed by default to change their owncode (refer to authority table). This feature can be disabled forany user without manager authority.LogOnSet On/Off If this option is on, the system will show a list of set groups thatare available to set. If only one set group is available settingwill start automatically.LogOn/Unset On/Off If this option is on then the authorised set groups, which areset will be unset when the user logs on.Shunt On/Off If this option is on the user has access to the shunt menuoption (33).Card+PIN On/Off If the user is configured with the Card+PIN option then BOTHthe PIN code and the card must be used to log onto a keypad.The PIN code and card may be used in any order. This optiondoes not apply when using an access module. If Card+PIN isoff then a user may log onto a keypad using EITHER a PINcode or card.Set group 1, max On/Off A user can be programmed any combination of set groups.3<strong>User</strong>-3<strong>User</strong> Name1=Name2=PIN3=Card4=Authority5=ACM Authority6=Schedule7=Lockout8=Expiry Date<strong>User</strong>-3Off0 2<strong>User</strong>-nnnnOrdinaryCode Change-OffLogOn/Set-OffLogOn/Unset-OffShunt-OffCard+PIN-OffGroup 1-OffGroup 2-Off…Group 32-Off?0=Off01=Master02=Ordinary03=Set/Uns04=Set05=Unset06=Cleaner07=Access10=ATM11=Log12=Bank Reset14=Guard- 21 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue B<strong>User</strong> Menu ACM Authority (<strong>PX</strong> Only) Code-5This option will only be available if at least one ACM is fitted to the system.Option Range DescriptionEnable On/Off If this option is off no further user ACM options will bedisplayed in this menu.LevelNormal,Visitor,Escort orThe access authority of each user can be programmed.SupervisorOn/OffACM 1 -maximumA user can be authorised for access through any combinationof ACM doors.Challenged On/Off If a user is programmed as challenged then the ACM doorrelease and open times will be automatically doubled for theuser.1=Name2=PIN4<strong>User</strong>-3Enable-Off3=Card4=Authority5=ACM Authority6=Schedule7=Lockout8=Expiry Date1<strong>User</strong>-3Enable-OnLevel-NormalACM 1-OffACM 2-Off. . .ACM 32-OffChallenged-Off?0=Normal1=Visitor2=Escort3=SupervisorACM Authority Level Access level Help Menu<strong>User</strong> access right will depend on the programmed user level and the programmed access door mode(programmed by the installation engineer). There are no restrictions on exit.Notes:<strong>User</strong> Access Restrictions<strong>User</strong> ModeDoor ModeNormal Dual Escort SupervisorNormal 1 Visitor 2 Escort 1 4 Supervisor (3) (3) (3) (3)1. Dual mode access requires 2 users with either Normal, Escort or Supervisor authority.2. A visitor user may only gain access within 10 seconds of an escort user presenting their token.3. A supervisor user can access a door with lockout enabled.4. An escort user can gain access by presenting their token twice within 10 seconds.<strong>User</strong> Menu Schedule Code-6A user can be programmed with a schedule to control access times. Program 00 to allow 24hraccess. The schedules can be programmed using option 25.- 22 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue B<strong>User</strong> Menu Lockout (<strong>PX</strong> Only) Code-7This option will only be available if at least one ACM is fitted to the system. If the lockout option is onfor a user then the user code will be ignored until the lockout is turned off.<strong>User</strong> Menu Expiry Date (<strong>PX</strong> Only) Code-8Expiry dates can be programmed for all users (panel and access users).1=Name2=PIN3=Card4=Authority5=ACM Authority6=Schedule7=Lockout8=Expiry Date7Expiry DateOffExpiry DateEnter DDMMYYYYExpiry DateThu 01 Jan 20040 1 0 1 2 0 0 4To delete an expiry date, enter the day and month of 0000 and the current year. The user authorityand codes will be removed from the system at midnight on the expiry date.Tel NumberCode-08An authorised user can change any telephone number that has been programmed to use the speechformat, home beep or SMS formats. The available formats will depend on the system hardwareoptions. A telephone number of up to 16 digits can be programmed. This number can include pausedigits. Pause digits can be entered using the button. This will be displayed as a “,” character. Eachpause digit represents a 1 second delay. Pauses may be required if you are signalling via a PABX orif the call is routed through an old exchange. Enter a single zero to turn off a telephone number. Pressto delete a single digit.08=Tel Number08Tel NumberNumber _1Tel Number-101313332900Tel Number-101313333802the number is not usedfor speech messagesenter thetelephone number+Not AvailableNo AuthorityAn alarm in the home beep format is transmitted as a series of DTMF tones. For example if channel 3was active the transmitted message would be:3 3 3 < 2s delay> 3 3 3 < 2s delay > 3 3 3 < 2s delay> 3 3 3 < 2s delay >3 3 3Where ‘3’ is the tone pair for DTMF digit 3. The channel information is repeated a maximum of 5 timesduring a call.- 23 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BLogsThe panel logs all events that occur in the system. All events stored in the event log are numbered inthe range 0-65535 (the event index). The event index will be reset to 0 when more than 65535 eventshave been recorded. There are 2 logs, the security log and, if an ACM(s) is fitted, an access log. Eachlog can be viewed in full or filtered form on a keypad and printed if a printer is connected to thesystem. Options 16-18 will only be displayed if there is at least one ACM on the system. Only eventsfor authorised areas and access doors will be displayed or printed.10=Log-Full11=Log-Cct12=Log-<strong>User</strong>13=Log-KP14=Log-Date15=Log-Alarm16=A/Log Full17=A/Log <strong>User</strong>18=A/Log Door1 01 11 21 3CircuitNumber-___<strong>User</strong>Number-____KeypadNumber-__1=Display2=Print1PIR in HallBypassed?12:00:00 Cct1Bypassed?Fri 3 Jan 2003000711 41 51 6Filter DateEnter-DDMMYYYYU2 Cct1Bypassed?1178<strong>User</strong>Number-____DoorNumber-__00001 Mon 07 Apr 2003 00:00:02 <strong>User</strong> 2 (Mr Smith) Logged On on KP 02Use the ? button to change thedisplay view of an event and thebuttons to change the event beingdisplayed. When an event is printed allthe event data is printed.?Event index Event date Event timeEvent detailsRefer to the appendix C for details of all log messages.TimeCode-20Some users have the authority to change the time by up to 75 minutes from the time set by theengineer if the user clock edit option is programmed. Time changes are recorded in the event log.20=Time20Time12:00Change greaterthan 75 minutesTimeEnter HH:MMOut of RangeTime13:001 3 0 0- 24 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BHolidayCode-24The programmed holidays are used in conjunction with the programmable schedules. The holidaydate format is day and month only. No year is entered therefore the entered date will remainprogrammed as a holiday for all years, or until it is removed from the holiday schedule. It is notpossible to program a holiday period that starts in December and ends in January. To achieve this 2holiday periods must be programmed.24=Holiday2 4HolidayNumber __01Holiday 1Start-OffHoliday 1Enter DDMMEnd-OffSet Group-00To disable a holiday enter a date of 00:00. The start and end dates must be in chronological order.Holidays may be optionally programmed to apply to individual set groupsScheduleCode-25A schedule consists of 4 times for each day of the week and 4 times for days which are holidays. Aschedule can be used to:1. Auto set and unset parts of the system2. Control outputs3. Enable/disable keypads4. Enable/disable user access5. Lock/unlock access doors25=ScheduleScheduleNumber __2 50 11=Mon2=Tue3=Wed4=Thu5=Fri6=Sat7=Sun8=Hol1 Schedule 1 MonStart 1-00:00Schedule 1 MonEnter HH:MMStop 1-00:00Start 2-00:00Stop 2-00:00Group TextCode-26A descriptor of up to 10 characters may be entered for each set group. Refer to appendix B for detailsof how to change a descriptor.- 25 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BMinutes Left (<strong>PX</strong>250HS Only)Code-27This option is only available to an ATM user. When an ATM user code and a non-zero ATM delayperiod is programmed then a delay prompt will be displayed when the ATM user code is first entered.27=Minutes left2 701=ATM 102=ATM 202The actual unset menuwill depend on the ATMuser authority and thegroup descriptors10 Minutes left=Ext. TimeATM 2UnsetExt. TimeOKIf the working time is less than 10 minutes, and an extension time is programmed, then the ATM usermay extend the working time. If the programmed ATM working time is more than 10 minutes then awarning will be given when the ATM user has 10 minutes working time left and the extend time promptwill be displayed automatically. Requests to extend the time will be logged. At the end of the workingtime the ATM user will be automatically logged off and areas that were unset by the ATM userwill be automatically set. If an ATM user logs off without setting the ATM user authorised areaswill be automatically set.Late WorkCode-28The late working option will only be displayed if at least one set group is programmed with a scheduleand late working has not been already selected. When the late working option is selected a list of allavailable set groups will be displayed. The late work time can be any time, including times aftermidnight. All late working actions are logged.28=Late Work2 81=Perimeter2=VaultLate Work00:00Late Work19:001Late WorkEnter HH:MM1 9 0 0- 26 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BBypassCode-30The bypass option will only be available if a circuit(s) has been programmed as bypassable by theinstallation engineer. The bypass circuit option allows the user to bypass a circuit that is in a faultcondition. When bypassed the alarm condition of a circuit is ignored. When a circuit is bypassed it isignored until the bypass is automatically removed when the circuit is next unset or until a userremoves the bypass. All bypass actions are stored in the event log. A bypass limit will have beenprogrammed by the installation engineer to limit the number of circuits that can be bypassed at anyone time. The system will display an error message if you try to exceed this limit.30=Bypass3 0CircuitNumber ___?CircuitLimit 1 to maxEnter circuitnumber01Circuit wasnot bypassedCct-01BypassedCircuit cannotbe bypassedNot AvailableNo AuthorityCircuit wasbypassedCct-01NormalMax. Number ofcircuits alreadybypassedCct-01NormalCircuit has a 24hrresponse and isalready bypassedCct-01ActiveCircuit is in a setareaCct-01SetNot AvailableAt Bypass LimitChimeCode-32Certain circuit types can be selected as chime circuits when unset. To select the chime function for acircuit, enter the circuit number. In the example chime is turned on for circuit 1.32=Chime 3 2CircuitNumber ___Circuit-1Front Door01Press anybuttonCircuit-1Chime-OffCircuit-1Chime-On1- 27 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BShuntCode-33A manager or ordinary user can be programmed with the shunt option. The shunt option will only bedisplayed if there are shuntable circuits in the user authorised areas. Shunted circuits may be viewedat any time using option 89 (Cct Status). All shunt actions are logged.33=ShuntCircuitNumber ___3 3Enter circuitnumber01Circuit wasnot shuntedCct-01Shunt OnCircuit cannotbe shuntedNot AvailableNot ProgrammedCircuit wasshuntedCct-01Shunt OffMax. Number ofcircuits alreadyshuntedNot AvailableShunt LimitPrint TextCode-40This option will only be available if a printer is connected to the system. The print text option will printall text descriptors.Print Hols.Code-42This option will only be available if a printer is connected to the system. The print holiday option willprint all holiday periods.Identify <strong>User</strong>Code-52This option allows a user to be identified by presenting the card/fob.52=Identify <strong>User</strong>5 2Present Card/Fob<strong>User</strong> 3 fob presentedUnused card/fob presentedCode Not Used <strong>User</strong> 3J Smith<strong>User</strong> 20 fob presented<strong>User</strong> 20J Black- 28 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BCopy <strong>User</strong>Code-7171=Copy <strong>User</strong>7 1Copy <strong>User</strong> ______-___Enter the user to copyhere.Enter the first and last userin the copy range here.To copy a single user, enter the same user number as the first and last.Copy A/<strong>User</strong> (<strong>PX</strong> Only)Code-73This option will only be available if at least one ACM is fitted to the system.73=Copy A/<strong>User</strong>7 3Copy A/<strong>User</strong> ________-____Enter the user to copyhere.Enter the first and last userin the copy range here.To copy a single user, enter the same user number as the first and last.Cct StatusCode-8989=Cct Status8 9Cct StatusNormalCct 1BypassedWhen the Cct Status option is selected the circuits thatare on soak test, bypassed, isolated or shunted will bescrolled on the display.- 29 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAccess Features (<strong>PX</strong> Only)The number of ACMs that can be connected depends on the panel variant:The table shows the access features across the panel range.Feature <strong>PX</strong>18 <strong>PX</strong>34 <strong>PX</strong>80 <strong>PX</strong>500ACMs 2 4 16 32Panel <strong>User</strong>s 20 40 100 200Access <strong>User</strong>s 100 100 1000 1000<strong>User</strong> expiry dates Challenged user option <strong>User</strong> lock out from keypad ACM Door lock/unlock from keypad Programmable unlock time Programmable Aux. relay time Anti pass back Access log events 1000 1000 1000 1000Access log real time print Set & unset Note: The panel users must be the first users in the system. For example on the <strong>PX</strong> 500 users 2-200may be access or panel users, users 201-1000 can only be access users and user 1 is always theengineer. The <strong>PX</strong> access control system can be configured through a security system keypad or a PCrunning GuardStation Access. <strong>Guardall</strong> <strong>PX</strong> proximity cards or fobs may only be introduced to thesystem through a <strong>PX</strong> keypad with an integrated proximity reader.Add A/<strong>User</strong>Code-50This option will only be available if at least one ACM is fitted to the system.50=Add A/<strong>User</strong> 5 0<strong>User</strong> 3Present Card/FobValid Card/Fobread<strong>User</strong> 4Present Card/FobThe first free user number is displayedThe user number is automatically incremented when avalid card/fob is presented.The user authority is automatically set to Access for all ACM doors and the user text descriptor will bedefaulted. If required the user authority can be changed using the edit user option.- 30 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BDelete <strong>User</strong>Code-51This option will only be available if at least one ACM is fitted to the system. In the example shown user3 is deleted from the system.51=Delete <strong>User</strong>s 5 1Delete <strong>User</strong>s____-____Delete <strong>User</strong>s3___-____3 Enter the range of users to delete.To delete a single user, enter theuser number twice. <strong>User</strong> numberscan be entered without leading zeros.Delete <strong>User</strong>s3___-3___3 Door UnlockCode-53This option will only be available if at least one ACM is fitted to the system. An ACM door can bemanually locked/unlocked from a keypad. An optional unlock time of up to 255 minutes can beprogrammed. If a time of zero is programmed the door will remain unlocked until the unlock option isturned off. While a door is locked it can still be opened by presenting a valid user card.53=Door UnlockDoorNumber _5 3The system can beprogrammed by theengineer to allow themanual door lock/unlock option tooverride the schedulecontrol.1Door 1Door Unlock-OffUnlock Time-0001Door 1Door Unlock-On- 31 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BDoor LockoutCode-54This option will only be available if at least one ACM is fitted to the system. The locked out ACM doorwill remain locked and will refuse all access attempts until the lockout is removed. The ACM doorlockout can only be removed through this programming option. The ACM door lockout will over-rideany user/ACM schedule permissions or otherwise immediately, and for the applied duration. Uponremoval the ACM door will be returned to its previous state (if that state still applies). Proximity readerLED’s will show the ACM door as locked out for the applied duration.54=Door LockoutDoorNumber _54An access user withsupervisor authority cangain access through a doorwith lockout enabled.1Door 1Door Lockout-Off1Door 1Door Lockout-On?0=Off1=OnACM TextCode-55A descriptor of up to 10 characters may be entered for each ACM. Refer to the appendix B for detailsof how to change a descriptor.- 32 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix A – <strong>User</strong> AuthoritiesAll user options with the appropriate authority level are shown in the table.Code Menu OptionManagerOrdinarySet/UnsSet01 Unset 02 Set 03 Reset 04 Test 05 Engineer 1 1 1 1 06 Code 2 2 2 07 <strong>User</strong> 08 Tel Number 10 Log-Full 11 Log-Cct 12 Log-<strong>User</strong> 13 Log-KP 14 Log-Date 15 Log-Alarm 16 A/Log-Full 17 A/Log-<strong>User</strong> 18 A/Log-ACM 20 Time 3 3 24 Holiday 25 Schedule 7 26 Group Text 27 Minutes Left 28 Late Work 30 Bypass 4 4 32 Chime 33 Shunt 40 Print Text 5 42 Print Hols. 5 50 Add A/<strong>User</strong> 6 51 Delete <strong>User</strong> 6 52 Identify <strong>User</strong> 53 Door Unlock 6 54 Door Lockout 6 55 ACM Text 6 71 Copy <strong>User</strong> 73 Copy A/<strong>User</strong> 89 Cct Status UnsetNotes:1. The Engineer option is not available to a user if the panel is programmed to allow theengineer to log on without user authorisation.2. The code option for some users will only be available if configured as part of the userauthority.3. The time can only be changed by a user if programmed by the engineer. <strong>User</strong> time changesare limited to +/- 75 minutes.4. The bypass option is only available if at least one circuit has been programmed to allowbypass.5. The print options are only available of a printer is connected to the system.6. The access options are only available if an ACM is fitted to the system7. The schedule option is only available if programmed by the engineer.CleanerAccessATMLogBank ResetGuard- 33 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix B – Editing TextA number of text descriptors may be changed by an authorised user. All changes to descriptors arelogged.Item Max. Length Default<strong>User</strong> 10 <strong>User</strong> xxSet group 10 Group xAccess control module 10 ACM x<strong>User</strong> Number-03J Smith<strong>User</strong> Number-03K Smith1<strong>User</strong> Number-03A Smith<strong>User</strong> Number-03A SmithA M Z1 2 3a m z4 5 61 9 space7 8 9save clear move 0 The allowed characters are:?When a descriptor is displayed the character being edited willbe flashing (this is shown as a grey character in thediagram).You can change a character using the numeric keys and/oruse the and buttons to move through the textcharacter set.ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz .-/+#%^&*@:!$?_0123456789- 34 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix C - Log MessagesAlarm & Event Log messagesLog Text Additional Data Display Text Event Description230v Fault NONE (see note) NONE Mains supply failed230v OK NONE (see note) NONE Mains supply restoredA/Set Fault Usnn, Area m Usnn, Am An area auto set with faultsActive Circuit Circuit nnn Cctnnn <strong>User</strong> selected active circuit testAlarm Circuit nnn Cctnnn A Circuit alarmAlarm (master shunt) Circuit nnn Cctnnn Master shunt type circuit alarmsAlarm Abort <strong>User</strong> nn, Keypad m Usnn, KPm Alarm abort signal transmitted.Anti mask Circuit nnn Cctnnn A Circuit program with the antimaskoption has alarmedAuth. Fail <strong>User</strong> nn Usnn Encryption authentication failAuto Check Fail Circuit nnn Cctnnn A Circuit has failed to activateduring the auto check period.Auto Check OK NONE NONE Circuit Auto Check was OKBat. Restore NONE (see note) NONE The battery voltage is normalafter a battery lowBat.Monitor Fail NONE (see note) NONE Battery voltage is low or notpresent during a battery testBattery Low NONE (see note) NONE The battery has reached the lowvolts threshold (after a mainsfail)Battery Low Transmitter number TXm Transmitter battery lowBypass<strong>User</strong> nn, Circuit mmm Usnn Cctmmm Circuit bypassedCannot set <strong>User</strong> nn, Area m Usnn, Am <strong>User</strong> was not able to set an areaCct Tested Circuit nnn Cctnnn Circuit responded in walk testChanged Code <strong>User</strong> nn, Keypad m Usnn, KPm <strong>User</strong> changes own codeChanged Code <strong>User</strong> nn, <strong>User</strong> mm Usnn, Usmm Manager or GSR user changescode for another userChanged Time <strong>User</strong> nn, Keypad m Usnn, KPm Time modified, old time and newtime are loggedCheck Fuse n N Panel fuse numberCheck Fuse Conc n Conc n Concentrator fuseCheck Fuse OPM n OPM n Output module fuseCheck Fuse ACM n ACM n ACM fuseClear Circuit nnn Cctnnn Master shunt type circuit clearsClear Circuit nnn Cctnnn A Circuit alarm has cleared.Code Clash <strong>User</strong> nn, <strong>User</strong> mm Usnn, Usmm <strong>User</strong> has chosen a new codewhich is the same as anotheruserComm Acknowledge n N Central station acknowledgealarm reportComm Fail NONE NONE Control panel comm fail inputactive.Comm Fail n N Central station fails toacknowledges alarm reportComm Fail Module name Module name Module has reported acommunications failComm Test <strong>User</strong> nn, Keypad m Usnn, KPm <strong>User</strong> or the panel tested thecommunicator(s)Commission Fail <strong>User</strong> nn Usnn Encryption commission failCommissioned <strong>User</strong> nn Usnn Encryption commission OKData Route Fail NONE NONE A call using the Dual comm dataroute has failed.Data Route OK NONE NONE A call using the Dual comm dataroute was successful.Date Changed Usnn Usnn Date changed (manual or auto)- 35 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAlarm & Event Log messagesLog Text Additional Data Display Text Event DescriptionDet Test Fail Usnn, Area m Usnn, Am One or more detector testcircuits failedDet Test OK Usnn, Area m Usnn, Am All detector test circuits testedOKDet.Test Fail<strong>User</strong> nn, Circuit mmm Usnn Cctmmm A detector circuit has failed torespond during a detector test.Dorm Confirm Circuit nnn Cctnnn Dormitory circuit confirmedDorm Init. Circuit nnn Cctnnn Dormitory circuit first activationDownload Fail GSRx GSRx Download from GSR x failedDownload OK GSRx GSRx Download from GSR x OKEnc.Sequence <strong>User</strong> nn Usnn Encryption sequence failEngineer Reset Circuit nnn Cctnnn Engineer reset type circuitalarmsEntry Alarm Area n An The area is not unset before theend of the entry warning periodEntry Started Circuit nnn Cctnnn Entry circuit opensExpiry Date Usnn Usnn Config change: <strong>User</strong> expiry datechange.Ext.Time <strong>User</strong> nn, Keypad m Usnn, KPm ATM user selected a timeextensionFailed Auto Set <strong>User</strong> nn, Area m Usnn, Am Event programmer failed to autoset due to circuits in alarmFault Radio module number RM nn Radio Module fault (no responsewhen unset). The system faultresponse option must beprogrammed. This option is onlyavailable in EN50131 compliantvariants.Fault Circuit nnn Cctnnn A Circuit short circuit whenunsetFault Keypad n KPn Failed poll when unsetFault Conc nn Conc nn Failed poll when unsetFault OPM nn OPM nn Failed poll when unsetFault SM n SM n Failed poll when unsetFault ACM nn ACM nn Failed poll when unsetFire Circuit nnn Cctnnn A fire type circuit alarmFire Door Open Circuit nnn Cctnnn Fire door open when unsetFirst code <strong>User</strong> nn, Keypad m Usnn, KPm <strong>User</strong> entered code on Dual codekeypadGSM Route Fail NONE NONE A call using the Dual commGSM route has failed.GSM Route OK NONE NONE A call using the Dual commGSM route was successful.GSR Poll Fail GSRx GSRx GSR number x poll fail.GSR Poll Rest. GSRx GSRx GSR number x polling restartedGSR Rejected NONE NONE A call from an unauthorisedGSR was rejected by the panel(the serial number was notprogrammed)Head Count Number Number of activations of allcircuits programmed with thehead count option while thepanel was unset.Incorrect PIN Keypad n KPn Maximum PIN attempts reachedIsol. Limit Area n An The isolate limit for the systemhas been reached.Isolate<strong>User</strong> nn, Circuit mmm Usnn Cctmmm Circuit isolated by userIsolate <strong>User</strong> nn, Concm Usnn, m Concentrator isolated by user- 36 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAlarm & Event Log messagesLog Text Additional Data Display Text Event DescriptionIsolate <strong>User</strong> nn, Keypad m Usnn, KPm Keypad isolated by userIsolate <strong>User</strong> nn, RMm Usnn, RMm Radio module isolated by userJamming Radio module number RM nn Receiver jammedKey Fail <strong>User</strong> nn Usnn Encryption key failKnock Circuit nnn Cctnnn Circuit first knockLate Working Usnn, Area m Usnn, Am Late working has been selectedfor the areaLine Fault Module name Module name Module has reported a line faultLockout Keypad n KPn Incorrect code attempt limitreached on the keypadLogged Off <strong>User</strong> nn, Keypad m Usnn, KPm <strong>User</strong> logged off keypadLogged On <strong>User</strong> nn, Keypad m Usnn, KPm <strong>User</strong> logged on keypadManaged Rst Keypad m KPm Managed reset code enteredMarginal Circuit nnn Cctnnn A Circuit is marginalMult. Alarm Circuit nnn Cctnnn Circuit has alarmed up to themultiple alarm limitNormal <strong>User</strong> nn, Concm Usnn, m Isolate removed from aconcentratorNormal<strong>User</strong> nn, Circuit mmm Usnn Cctmmm Bypass or isolate removed froma circuitNot Unset Area n An A set group was not unset bythe schedule close timePanel Tamper NONE NONE Panel case or off thewall tamperPC Access GSRx Operator YY GSRx Operator GSR operator number YY hasYYlogged on from GSR number x.PC Disconnect GSRx Operator YY GSRx Operator GSR operator number YY hasYYlogged on from GSR number x.Personal Attack Circuit nnn Cctnnn A PA type circuit alarmPoll Fail Transmitter number TX nn, RM mm Transmitter polling failurePoll Fault Radio module number RM nn Receiver polling faultPower Fail NONE (see note) NONE Supply voltage hasfallen to the power fail thresholdPSTN Route Fail NONE NONE A call using the Dual commPSTN route has failed.PSTN Route OK NONE NONE A call using the Dual commPSTN route was successful.Remote Service GSRx GSRx Remote Service CompleteReprogrammed Refer to table Refer to table Item menu description plusoptional number (see note)Reset Circuit nnn Cctnnn An area has been resetReset <strong>User</strong> nn, Area m Usnn, Usnn An area has been resetRestored Code(s) <strong>User</strong> nn, Keypad m Usnn, KPm All codes have been restored todefaultRmt.Auth Fail NONE NONE Repeated attempt to log on by aremote hostSession End <strong>User</strong> nn Usnn Encryption session endSet <strong>User</strong> nn, Area m Usnn Am Area has been set by a userSet <strong>User</strong> nn, Group m Usnn m Group has been set by a userSet Req. Circuit nnn Cctnnn Key type circuit alarmsSet Req. <strong>User</strong> nn, Keypad m Usnn, KPm A user requested set on akeypad (dual set programmed)Shunt Limit Area n An The shunt limit for the systemhas been reached.Shunt Off<strong>User</strong> nn, Circuit mmm Usnn Cctmmm Shunted removed from circuitShunt On<strong>User</strong> nn, Circuit mmm Usnn Cctmmm Shunt applied to circuit- 37 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAlarm & Event Log messagesLog Text Additional Data Display Text Event DescriptionSndr Tamper NONE NONE Panel sounder tamperSoak Alarm Circuit nnn Cctnnn A circuit on soak test hasalarmedSoak Failed Circuit nnn Cctnnn At the end of the soak periodany circuit which has alarmed islogged as failedSoak Off Circuit nnn Cctnnn A circuit has been taken off soakSoak On Circuit nnn Cctnnn A circuit has been put on soakSoftware Error N N A software error has beenloggedTamper n n Concentrator TamperTamper Circuit nnn Cctnnn A circuit tamperTamper Keypad n KPn A keypad tamperTamper SM n SMn A serial module tamperTamper OPM n OPMn An output module tamperTamper ACM n ACMn An ACM tamperTamper Radio module number RM nn Radio Module tamperTemp Bypass Circuit nnn Cctnnn A circuit has been temporarily(until clear) bypassedTX Off N N TX channel N offTX On N N TX channel N onUnset <strong>User</strong> nn, Area m Usnn Am A user has unset the areaUnset <strong>User</strong> nn, Group m Usnn m Group has been unset by a userUnset Req. Circuit nnn Cctnnn Key type circuit clearsUnset Req. <strong>User</strong> nn, Keypad m Usnn, KPm A user requested unset on akeypad (dual unset or unsetdelay programmed)Upload Fail GSRx GSRx Upload to GSR x failedUpload OK GSRx GSRx Upload to GSR x OKVerify Alm Area n An A verified alarm has occurredWatchdog NONE NONE Software watchdog activeAppendix C – Access Log MessagesAccess Control log only messagesLog Text Additional Data Display Text Event DescriptionAccess <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> accessed ACM mCard Exit <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> exit by ACM m, which hasno door contactDenied <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> denied access ACM mDoor Open ACM m ACMm ACM door held openExit <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> exit by ACM mForced ACM m ACMm ACM door forced openLock ACM m ACMm ACM door lockPending ACM m ACMm Schedule unlock pendingRTE ACM m ACMm ACM Door RTE button activeSet Req. <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> request to set from ACM mUnlock ACM m ACMm ACM door unlockedUnset Req. <strong>User</strong> nn, ACM m Usnn, ACMm <strong>User</strong> request to unset from ACMm- 38 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix E - Menu RestrictionsIf a menu number is entered and the option is not available, then a reason will be displayed. Forexample if no area is set and you select unset the panel will prompt with the reason the unset option isnot available.Not AvailableNo Set AreaThis indicates that there is no set area available to the user.There are many reasons why an option is not available. If you think an option should be available butthe prompt is not on display then enter the menu number and the panel will display an appropriatemessage. The following table shows the reasons why a menu option is not available:Not Available MessageAt Bypass LimitCall EngineerHigh Level SetIsolate LimitIsolatedKey Not UsedKeypad BusyLow Level UnsetNo AuthorityNo Set AreaNo Unset AreaNot ApplicableNot ProgrammedOption in UsePrinter BusySet AreaShunt LimitSystem Not UnsetTest in ProgressTest SystemTimer Control OnUnset AreaWhere Used<strong>User</strong> attempts to bypass a circuit when the number of bypassed circuits isat the programmed bypass limit.<strong>User</strong> attempts to set when an engineer reset is required.<strong>User</strong> attempts to unset a lower level group without unset higher levels<strong>User</strong> attempts to isolate a circuit when the maximum allowed number ofcircuits are already isolated<strong>User</strong> attempts to bypass a circuit that is isolated.The key (button) which has been pressed is never used in the currentmenu.<strong>User</strong> attempts to turn off a keypad that is being used.<strong>User</strong> attempts to set a higher level group without setting lower levels<strong>User</strong> tries to select an option that is not allowed with their programmedauthority level.<strong>User</strong> selects unset when all areas that can be unset from the keypad arealready unset.<strong>User</strong> selects set when all areas that can be set from the keypad arealready set.<strong>User</strong> attempts, for example, to reset when there are no alarms logged.The option selected is not programmed.<strong>User</strong> selects an option, such as test, which is in being used by anotheruser.<strong>User</strong> attempts to print and the printer is in use.<strong>User</strong> attempts to access test when an area is set.<strong>User</strong> attempts to shunt a circuit when the maximum allowed number ofcircuits are already shunted<strong>User</strong> attempts to access an option that is only available when the systemis unset, for example the event log.<strong>User</strong> attempts to set an area that is being tested (on another keypad).Circuit check fail has occurred and the user has selected set<strong>User</strong> attempts to log on outwith the schedule times.<strong>User</strong> attempts to unset an unset area.- 39 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix E - Log On MessagesWhen a user logs on, the system may display a special message(s) before the normal menu isdisplayed. The special messages are shown in the table.MessageReasonAlarm Abort<strong>User</strong> logs on within the alarm abort period (programmable option)Call Engineer You should call the installation company. The details will then be displayed.Cannot SetThe system cannot set, the reason(s) will then be displayed.Code Known Another user has chosen your code. You will then be given the option ofimmediately changing your code. This message will always be displayed onlog on until the code is changed.Det.Test FailArea xA detector in area x has failed an automatic detector test. Note that thiswarning will not be shown if the log on set option applies.Group Unset A group(s) is set and is programmed to automatically unset when a user logson.Mult.Alarm A circuit(s) has alarmed the maximum number of times allowed(programmable). The circuit details will then be displayed.Reset OKA managed reset code has been acceptedSetting Stopped <strong>User</strong> logs on during the setting exit periodSoak Cct Fails Circuits which have been put on special test by the installation engineer havealarmed.Unset Alarm An unset alarm has occurred, the details will then be displayed.- 40 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix F – Audio CommandsThis section only applies to systems that are fitted with an audio bus or a speech module. The speechand audio functions of the system by using a DTMF telephone handset. To use an audio or speechfunction:1. Dial the control panel telephone number2. Log on using your PIN code and terminate with the # button3. Enter the required function codeCodeMeaning*01# - *32# Activate TalkBack modules 1 to 32*00# Activate all TalkBack modules# Toggle between listen and talk modes*59# Replay stored audio (the system must be fitted with an audio interfacewith the speech record option)*40# Record main message*41# - *49# Record channel messages 1 to 8*410# Record set message*411# Record unset message*50# Play main message*51# - *59# Play channel message 1 to 8*510# Play set message*511# Play unset message*61# - *68# Turn on output 1 to 8 (the selected output must be programmed by theengineer)*171# - *178# Turn off output 1 to 8 (the selected output must be programmed by theengineer)*010# Unset system*01nn# Unset group n, where n = 1 to 32*020# Set system*02nn# Set group n, where n = 1 to 32*03nn# Status of set group n, where n = 1 to 32* Cancel command*# shut down callNote that all commands except toggle are preceded with a “*” and you must wait for the confirm toneafter the “*” before pressing “#”.Message LengthFunction(seconds)0 8 Main message sent with all speech format alarm reports1-8 4 Channel messages sent when the corresponding channel isactive9 6 Memo message or stored audio message- 41 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BAppendix G - System DetailsNumber of AreasNumber of keypadsNumber of CircuitsNumber of <strong>User</strong>sService NumberContract NumberKeypadsNumberLocation12345678Set GroupsNumber12345678DescriptionAreas1 2 3 4 5 6 7 8- 42 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BCircuitsNumber Description LocationCct 1Cct 2Cct 3Cct 4Cct 5Cct 6Cct 7Cct 8Cct 9Cct 10Cct 11Cct 12Cct 13Cct 14Cct 15Cct 16Cct 17Cct 18Cct 19Cct 20Cct 21Cct 22Cct 23Cct 24Cct 25Cct 26Cct 27- 43 -


<strong>PX</strong>/<strong>QX</strong>/<strong>RX</strong> <strong>Version</strong> <strong>4.20</strong> <strong>User</strong> <strong>Manual</strong> – Issue BNumber Description LocationCct 28Cct 29Cct 30Cct 31Cct 32Cct 33Cct 34<strong>User</strong>sNumber2345678DescriptionAreas1 2 3 4- 44 -


<strong>Guardall</strong> LimitedLochend Industrial EstateNewbridgeEdinburgh EH28 8PLTel: 0131-333-2900FAX: 0131-333-4919Technical Hotline: 0131-333-3802Part Number: 320995-0B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!