11.07.2015 Views

Voltammetric Determination of Iron - Metrohm

Voltammetric Determination of Iron - Metrohm

Voltammetric Determination of Iron - Metrohm

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Application Bulletin 317/1 e<strong>Voltammetric</strong> <strong>Determination</strong> <strong>of</strong> <strong>Iron</strong>Page 10/13797 VA Computrace method printout for Method 1 «<strong>Determination</strong> <strong>of</strong> iron in samples > 200 µg/L»--------------------------------------------------------------------------------Method parameters--------------------------------------------------------------------------------Method: AB317_1 Det <strong>of</strong> Fe above 200 ppb.mthTitle: <strong>Determination</strong> <strong>of</strong> Fe (TEA method)Remark1: 10 mL sample + 2 mL electrolyteRemark2: Electrolyte (0.05M TEA, 0.1M KBrO3, 0.3M NaOH)CalibrationTechniqueAddition: Standard addition: Batch: AutomaticSample ID :Sample amount (mL): 10.000Cell volume (mL): 12.000<strong>Voltammetric</strong> parameters--------------------------------------------------------------------------------Mode: DP - Differential PulseHighest current rangeLowest current range: 10 mA: 100 nAElectrode: DMEStirrer speed (rpm) : 2000Initial electr. conditioning : YesStandard deviation : 0.50 %No. <strong>of</strong> additions : 2No. <strong>of</strong> replications : 2Measure blank: NoAddition purge time (s) : 60Initial purge time (s) : 300SweepEquilibration time (s) : 5.000Start potential (V) : -0.700End potential (V) : -1.250Voltage step (V) : 0.006Voltage step time (s) : 0.500Sweep rate (V/s) : 0.012Pulse amplitude (V) : 0.050Pulse time (s) : 0.040Cell <strong>of</strong>f after measurement : YesPeak evaluation--------------------------------------------------------------------------------Regression technique: Linear RegressionPeak evaluation: HeightMinimum peak width (V.steps) : 5Minimum peak height (A): 1.000e-010Reverse peaks: NoSmooth factor : 4Eliminate spikes: YesSubstances--------------------------------------------------------------------------------Fe : -0.96 V +/- 0.0500 VStandard solution : 1 10.000 mg/LAddition volume (mL) : 0.200default : Final result (Fe) =Conc * (12.1 / 10) * (1e+006 / 1) + 0 - 0Baseline--------------------------------------------------------------------------------Substance Addition automatic start (V) end (V) type scope--------------------------------------------------------------------------------Fe Sample yes --- --- linear wholePeakAddition 1 yes --- --- linear wholePeakAddition 2 yes --- --- linear wholePeak--------------------------------------------------------------------------------

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!