11.07.2015 Views

AUTOPSY SINKS, TABLES AND CARTS - Mopec

AUTOPSY SINKS, TABLES AND CARTS - Mopec

AUTOPSY SINKS, TABLES AND CARTS - Mopec

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CF Series Embalming Workstations1234567891011CF200 Embalming Sink shown with CF400 Embalming CartThe CF Embalming SinkThe Embalming Sink incorporates all the necessary featuresfor full body embalming. The sink includes a hot and coldwater fixture with a hydro-aspirator that is conveniently locatedto aspirate any fluids from the body in preparation forembalming. A body rinse fixture is provided for the cleaningand rinsing process during the final stages of body embalming.Heavy-duty grid plates are utilized to support the embalmingmachine. The drain surface below the grid plates are tiltedtoward the large sink, which includes a perimeter rinse. Theperimeter rinse prevents fluids from accumulating anywhere onthe surface. All utilities including water, electrical, drain and airventilation are attached to the embalming cart with quickdisconnects.Product DescriptionProduct No. CF100 — Right Approach SinkProduct No. CF200 — Left Approach SinkProduct No. CF300 — Center Approach SinkNOTE: Quantity of standard features may vary based upon modelthat is ordered. Example - instrument rinse tray is only on CF100and CF200 due to space constraints. Please contact <strong>Mopec</strong> formore information when ordering.CF Series Standard FeaturesDissection Area and Sink Well and Back Splash: Fabricatedwith a 2" (5 cm) rim and full 1" (2.5 cm) radiused corners, thedrain board areas are recessed 2" (5 cm) and sloped with a 1"(2.5 cm) drop toward the main sink well. The main sink is 6" (15.3cm) deep and holds approxi mately 18 gallons. Double creased forcomplete drainage and integrally constructed with the backsplash, it has no seams or caulk joints.Front Panel: Integral sink to front panel construction with nohidden areas for bacteria growth.Grid Plates: Work surface is elevated using removable gridplates above the drain area. Mounting is accomplished withoutpins, making them completely interchangeable and easilycleaned. The grid plates are perforated and recessed 1/2" (1.3 cm)below the sink ledge. (CF100 and CF200 have three grid plates,CF300 will have four grid plates).Instrument Rinse Tray: A built in instrument rinse tray can beused to rinse or drain organs and/or instruments. (The basket hasa grid panel design. Instrument rinse tray is only available on theCF100 and CF200.)Drawer: Drawers are flush mounted with a continuous handle.Double pan construction with built in slides. (CF100 and CF200have one drawer, CF300 has two, one on each side.)Hydro-Aspirator: Deluxe Hydro-Aspirator has a reverse flowfeature that instantly relieves clogging. Plumbed with a vacuumbreaker which prevents any pollutants from entering the watersystem.Faucet: Hot and cold water fixture with convenient wrist bladehandles, goose neck faucet and vacuum breaker fixture mounteddirectly on faucet.Receptacles: GFCI duplex receptacle with waterproof enclosure,cover. (CF100 and CF200 have one receptacle, CF300 has two.)Exhaust Duct: Ventilation exhaust ducting, located over the dissectionarea of the table, is designed to remove pungent odors.Body Rinse: A body rinse is provided which consists of a coldwater valve, serrated hose fitting, vacuum breaker, 8 ft. (243 cm)of clear tubing and hose hanger bracket. (CF100 and CF200have one body rinse, CF300 has two, one on each side).Hand Spray: Fabricated of a heavy-duty brass chrome platedhand held fixture with 8 ft. (243 cm) high pressure hose. (CF100and CF200 have one hand spray, CF300 has two, one on eachside).24821750 Coolidge Hwy. Oak Park, MI 48237 USA 800-362-8491 248-291-2040 www.mopec.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!