11.07.2015 Views

Model P-600 SIC Analyzer - OrbInstruments.com

Model P-600 SIC Analyzer - OrbInstruments.com

Model P-600 SIC Analyzer - OrbInstruments.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PRODUCT GUIDEPetroleum <strong>Analyzer</strong>s•Flash Point•Salt In Crude•RVP•RVP/VL20•Freeze Point•Cloud Point•Pour Point•Viscosity•Viscosity IndexWater <strong>Analyzer</strong>s•UV-COD•UV-Oil in WaterOther Products•Environmental Cabinets•Sample ConditioningSystems•Sample RecoverySystems•Spare Parts<strong>Analyzer</strong> Services•Field Service•Start-Ups•Training•Technical SupportSPECIFICATIONS: MODEL P-<strong>600</strong> SALT IN CRUDE ANALYZERANALYSIS PERFORMANCEMeasurement Cycle Time6 minutes or lessMeasurement Range0 to 400 PTB, 0 to 1000 mg/liter (selectable)Repeatability2 % of scale or betterReproducibility± 1 % of scaleResolution± 0.5 % of scaleAccuracy +/- 5% of measurment, correlates to ASTM D 3230Conductivity Accuracy0.5 % of full scaleTemperature Accuracy± 0.1°C (± 0.2°F) of full scaleSAMPLE REQUIREMENTSSample Bypass Flow Rate 2.0 L/minSample Return PressureAtmospheric – Max. 35 psi (2.4 bar) - optional high pressure sample recovery systemavailable (P/N 700172)Sample PressureMin. 60 psi (4.0 bar) – Max. 210 psi (14.0 bar) - optional sample conditioning systemheating option existsSample TemperatureMin. 50°F (10°C) – Max. 140°F (60°C)Sample Conditionshomogenous, single-phase sample without waterENCLOSURE/INSTALLATION REQUIREMENTSDimensionsWidth 38.0 in (955mm) – Height 73.0 in (1854mm) – Depth 30 in (762mm)Weightapproximately 500 lbs (228 kg)Operating TemperatureMin. 40°F (5°C) – Max. 105°F (40°C)Enclosure Material/RatingX-Proof housingsArea ClassificationNEC Class 1 Div 1 Group B, C + DPowerauto-selecting 100 to 120 VAC or 200 to 240 VAC (± 10%), 50/60 Hz, single phase, 5AOptional Vortex Gas SupplyCell Purge Gas SupplyEND USER CONNECTIONSAnalog Output SignalRelay Output ContactSerial Input/Output SignalSOLVENT REQUIREMENTSXyleneAlcohol MixtureHOW TO ORDERANALYZER SYSTEMSCatalog Number P-<strong>600</strong>-1400ACCESSORIESCatalog Number 700228Catalog Number 700641Catalog Number 700642Clean, Dry Instrument air at Min. 80 psi (5.5 bar) – Max. 120 psi (8.2 bar)Clean, Dry Instrument air at Min. 20 psi (1.4 bar) – Max. 35 psi (2.4 bar) / approx. 20ccm/min flow rate at 20% duty cyclesingle isolated 4-20 mA output (optional second output available), selectable for sample<strong>SIC</strong> values, analyzer system/maintenance warning or analysis measurement indicationthree SPDT Relays with contacts rated at 3A resistive load at 250VAC ,selectable forsample <strong>SIC</strong> value alarm, analyzer maintenance warning or analyzer fault alarmsingle RS232 or RS485 bi-directional / optional ModBus output availableper ASTM D84337/63 mix of Absolute Methanol and n-Butanol(reagent grade)Orb <strong>Model</strong> P-<strong>600</strong> RVP <strong>Analyzer</strong>, Ex Area ready for NEC Class 1 Div 1 Group C + DHigh Pressure Sample Recovery System (for sample return pressures greater than 35 psi(2.4 bar) up to Max. 120 psi (8.3 bar))1-Year Spare Parts Kit2-Year Spare Parts KitLit. No. P-<strong>600</strong>XP-EN-US / JAN10ORB Instruments, Inc.4724 South ChristianaChicago, IL 60632 / USAPhone: + (1) 773 927-8<strong>600</strong>Fax: + (1) 773 927-8620Email: sales@orbinstruments.<strong>com</strong>www.orbinstruments.<strong>com</strong>This publication is not intended to form the basis of a contract. The <strong>com</strong>pany reserves the right to change design and specification of its products without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!