Model P-600 SIC Analyzer - OrbInstruments.com
Model P-600 SIC Analyzer - OrbInstruments.com
Model P-600 SIC Analyzer - OrbInstruments.com
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
PRODUCT GUIDEPetroleum <strong>Analyzer</strong>s•Flash Point•Salt In Crude•RVP•RVP/VL20•Freeze Point•Cloud Point•Pour Point•Viscosity•Viscosity IndexWater <strong>Analyzer</strong>s•UV-COD•UV-Oil in WaterOther Products•Environmental Cabinets•Sample ConditioningSystems•Sample RecoverySystems•Spare Parts<strong>Analyzer</strong> Services•Field Service•Start-Ups•Training•Technical SupportSPECIFICATIONS: MODEL P-<strong>600</strong> SALT IN CRUDE ANALYZERANALYSIS PERFORMANCEMeasurement Cycle Time6 minutes or lessMeasurement Range0 to 400 PTB, 0 to 1000 mg/liter (selectable)Repeatability2 % of scale or betterReproducibility± 1 % of scaleResolution± 0.5 % of scaleAccuracy +/- 5% of measurment, correlates to ASTM D 3230Conductivity Accuracy0.5 % of full scaleTemperature Accuracy± 0.1°C (± 0.2°F) of full scaleSAMPLE REQUIREMENTSSample Bypass Flow Rate 2.0 L/minSample Return PressureAtmospheric – Max. 35 psi (2.4 bar) - optional high pressure sample recovery systemavailable (P/N 700172)Sample PressureMin. 60 psi (4.0 bar) – Max. 210 psi (14.0 bar) - optional sample conditioning systemheating option existsSample TemperatureMin. 50°F (10°C) – Max. 140°F (60°C)Sample Conditionshomogenous, single-phase sample without waterENCLOSURE/INSTALLATION REQUIREMENTSDimensionsWidth 38.0 in (955mm) – Height 73.0 in (1854mm) – Depth 30 in (762mm)Weightapproximately 500 lbs (228 kg)Operating TemperatureMin. 40°F (5°C) – Max. 105°F (40°C)Enclosure Material/RatingX-Proof housingsArea ClassificationNEC Class 1 Div 1 Group B, C + DPowerauto-selecting 100 to 120 VAC or 200 to 240 VAC (± 10%), 50/60 Hz, single phase, 5AOptional Vortex Gas SupplyCell Purge Gas SupplyEND USER CONNECTIONSAnalog Output SignalRelay Output ContactSerial Input/Output SignalSOLVENT REQUIREMENTSXyleneAlcohol MixtureHOW TO ORDERANALYZER SYSTEMSCatalog Number P-<strong>600</strong>-1400ACCESSORIESCatalog Number 700228Catalog Number 700641Catalog Number 700642Clean, Dry Instrument air at Min. 80 psi (5.5 bar) – Max. 120 psi (8.2 bar)Clean, Dry Instrument air at Min. 20 psi (1.4 bar) – Max. 35 psi (2.4 bar) / approx. 20ccm/min flow rate at 20% duty cyclesingle isolated 4-20 mA output (optional second output available), selectable for sample<strong>SIC</strong> values, analyzer system/maintenance warning or analysis measurement indicationthree SPDT Relays with contacts rated at 3A resistive load at 250VAC ,selectable forsample <strong>SIC</strong> value alarm, analyzer maintenance warning or analyzer fault alarmsingle RS232 or RS485 bi-directional / optional ModBus output availableper ASTM D84337/63 mix of Absolute Methanol and n-Butanol(reagent grade)Orb <strong>Model</strong> P-<strong>600</strong> RVP <strong>Analyzer</strong>, Ex Area ready for NEC Class 1 Div 1 Group C + DHigh Pressure Sample Recovery System (for sample return pressures greater than 35 psi(2.4 bar) up to Max. 120 psi (8.3 bar))1-Year Spare Parts Kit2-Year Spare Parts KitLit. No. P-<strong>600</strong>XP-EN-US / JAN10ORB Instruments, Inc.4724 South ChristianaChicago, IL 60632 / USAPhone: + (1) 773 927-8<strong>600</strong>Fax: + (1) 773 927-8620Email: sales@orbinstruments.<strong>com</strong>www.orbinstruments.<strong>com</strong>This publication is not intended to form the basis of a contract. The <strong>com</strong>pany reserves the right to change design and specification of its products without notice.