11.07.2015 Views

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SRLSelf-Regulating LowTemperature (cont’d.)<strong>Heat</strong>ing CableOrdering InformationOutput(W/Ft.) Volts Model Stock PCNSRL 3-1C S 382678120 SRL 3-1CT S 383400SRL 3-1CR S 3827313 @ 50°F5 @ 50°F8 @ 50°F10 @ 50°FAccessories208 - 277120208 - 277120208 - 277120208 - 277SRL 3-2CSRL 3-2CTSRL 3-2CRSRL 5-1CSRL 5-1CTSRL 5-1CRSRL 5-2CSRL 5-2CTSRL 5-2CRSRL 8-1CSRL 8-1CTSRL 8-1CRSRL 8-2CSRL 8-2CTSRL 8-2CRSRL 10-1CSRL 10-1CTSRL 10-1CRSRL 10-2CSRL 10-2CTSRL 10-2CRSSSSSSSSSSSSSSSSSSSSSTo Order — Specify length, model, PCN <strong>and</strong> installation accessories.382686383419382740382694383443382758382707383451382766382555383460382598382563383478382600382820383486382846382838383494382854Wt./1000'(Lbs.)536664536664536664536664536664536664536664536664Accessories U Series DL ELPower Connection <strong>Heat</strong> trace to electrical service connection UPC RTPC SSKSplice & Tee UMC RTST RT-RSTEnd Seal For terminating cable UES RTES RT-RESLighted End Seal USL RTST-SL N/AThermostat Ambient air sensing thermostat UAS RTAS THL/TXLLine sensing mechanical thermostat UBC RTBC THR/TXRTo Order — General Application & Installation Accessories such as tape, pipe straps,warning labels, etc., refer to the U Series, DL & EL General ApplicationAccessories page at the end of this section.More Informationis Available Onlineon <strong>Heat</strong> Trace.Bookmark Your Browser towww.chromalox.com<strong>and</strong> Select Manuals.OrderingInformationTo Order —Complete theModel Numberusing the Matrixprovided.Contact your Local<strong>Chromalox</strong> Salesoffi ce for monitorwire option.Model Self-Regulating Low TemperatureSRL Self-Regulating, Low Temperatue <strong>Heat</strong>ing CableCode Output (W/Ft.)3 Three5 Five8 Eight10 TenCode Voltage1 1202 208 - 277Code Braid <strong>and</strong> Overcoat OptionsCTin-Plated copper metallic braid foradditional protection <strong>and</strong> ground pathCT Fluoropolymer corrosion resistantoverjacket over braid for hostile/corrosiveenvironmentsCR TPR overjacket over braid for protectionagainst certain inorganic chemicalsolutionsSRL 5 1 C Typical Model Number84

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!