11.07.2015 Views

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ComfortKUHHorizontal Blower<strong>Heat</strong>er (cont’d.)Recommended <strong>Control</strong> OptionsPCNDescriptionOnlyThermostatKitsFanOnlyRemoteFanDisconnect304320 KUH-20-23-34 240V 3P 20kW KUH-TK3 ISFS-02 ESFS-42A KDS-2304338 KUH-20-43-30 480V 3P 20kW KUH-TK3 ESFS-40A ESFS-40A KDS-1304346 KUH-25-43-30 480V 3P 25kW KUH-TK3 ESFS-40A ESFS-40A KDS-1304354 KUH-30-83-34 208V 3P 30kW KUH-TK3 ISFS-02 ESFS-42A KDS-3304362 KUH-30-23-34 240V 3P 30kW KUH-TK3 ISFS-02 ESFS-42A KDS-2304370 KUH-30-43-30 480V 3P 30kW KUH-TK3 ESFS-40A ESFS-40A KDS-1304389 KUH-35-23-34 240V 3P 35kW KUH-TK3 ISFS-02 ESFS-42A KDS-3304397 KUH-35-43-30 480V 3P 35kW KUH-TK3 ESFS-40A ESFS-40A KDS-2304400 KUH-40-23-34 240V 3P 40kW KUH-TK3 ISFS-02 ESFS-42A KDS-3304418 KUH-40-43-30 480V 3P 40kW KUH-TK3 ESFS-40A ESFS-40A KDS-2304426 KUH-45-43-30 480V 3P 45kW KUH-TK3 ESFS-40A ESFS-40A KDS-2When ordering KUH heaters, specify the model number <strong>and</strong> corresponding PCN (Product Code Number). If controls or thermostat/fan options arerequired, designate these options in the model number when ordering, as shown below. Always specify voltage, phase <strong>and</strong> kW by listing them onthe purchase order product specifi cations.Model Numbers<strong>Chromalox</strong> Horizontal Unit <strong>Heat</strong>er<strong>Heat</strong>ing Elements20 20.0 kW 40 40.0 kW25 25.0 kW 45 45.0 kW30 30.0 kW35 35.0 kW<strong>Heat</strong>er Voltage <strong>and</strong> Phase81 208V, 1 Phase 71 277V, 1 Phase83 208V, 3 Phase 43 480V, 3 Phase21 240V, 1 Phase 63 600V, 3 Phase23 240V, 3 Phase<strong>Control</strong>00 No Contactor(s)30 24V <strong>Control</strong> Internal Transformer31 24V <strong>Control</strong> Externally Supplied32 120V <strong>Control</strong> Internal Transformer33 120V <strong>Control</strong> Externally Supplied34 208/240V <strong>Control</strong> Internally Supplied, No Transformer35 277V <strong>Control</strong> Internally Supplied<strong>Control</strong>00 No Thermostat, No Summer Fan Switch40 Internal Thermostat Only41 Internal Therm. <strong>and</strong> Internal Sum. Fan Sw.42 External Sum. Fan Sw. Only (Not 480 V)43 External Sum. Fan Sw. <strong>and</strong> Fan Relay (All Volts)44 Rem. Fan Sw. <strong>and</strong> Internal Therm. (Not 480 V)45 Rem. Fan Sw., Fan Relay <strong>and</strong> Int. Therm. (All Volts)D, E, F, G46 Internal Sum. Fan Sw. (Not 480 V)47 Internal Sum. Fan Sw., Fan Relay (All Volts)Disconnect Switch1 40 Amp2 80 Amp3 100 AmpKUH 20 43 31 41 1 Typical Model Number14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!