11.07.2015 Views

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Control</strong>s®HTAS<strong>Heat</strong> Tracing Ambient Sensing<strong>Control</strong> PanelSeries 8000/12000/24000• Color Touchscreen OperatorPanel• Eight/Twelve/Twenty-FourPoints of Power <strong>Control</strong>• Optional Ambient Sensing<strong>Control</strong>ler• NEMA 4 Enclosure• Low Current Alarmwith Adjustable Setpoint• Ground Fault Alarming/Trip• Common Alarm Output(Re-Ring Feature)• Load Management• Process Loop Identification• Internal Power Distribution(Includes Circuit Breakers)• 120, 240, 480, <strong>and</strong> 277 Vac• Auto-Cycle Feature• Current Display• Network Communications• H<strong>and</strong>/Off/Auto Selection• Enclosure <strong>Heat</strong>er Option forSub-Zero Ambients• Z-Purge Option for Operation inClass I, Div. 2 AreasDescriptionThe IntelliTRACE HTAS Series is a microprocessorbased Monitoring <strong>and</strong> Power Management/Distributionsystem for <strong>Heat</strong> TraceApplications.The IntelliTRACE Multi-Channel <strong>Heat</strong> TraceSystem provides Alarms for Continuity, <strong>and</strong>Ground Fault Leakage. The Advanced Featuresinclude a Color Touchscreen Operator InterfacePanel that provides simple programmingwith no keyboards or cryptic labels. The paneldisplays loop status, alarm conditions <strong>and</strong>graphics on currents.With the built-in power distribution, the Intelli-TRACE multi-loop provides reduced material,installation, <strong>and</strong> maintenance costs. Theload management feature eliminates the needfor expensive ground fault breakers, limitsinrush current <strong>and</strong> systematically interrogatesall circuits for continuity <strong>and</strong> ground faultleakage.Technical SpecificationsSupply Voltage: 120, 240, 480, <strong>and</strong> 277Vac,Three-PhaseOperating Environment: 32 to 120°F(0 to 40°C) -30 to 104˚F (-34 to 40˚C) withenclosure heater optionCommunications: RS-485 MODBUS ®Output: Two-Pole ContactorsMaximum Current: 24 Amps/CktGround Fault Alarm: Adjustable 25 – 500mAFactory Set @ 30mALow Current Alarm: .2 - 24.0 AdjustableLoad Management: 15 sec. Non-Overlap toReduce Inrush.Auto-Cycle: Programmable to 720 Hrs (30days)<strong>Control</strong> Mode: Optional Ambient Sensing<strong>Control</strong>ler.158

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!