11.07.2015 Views

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

Cold Weather Catalog - Chromalox Precision Heat and Control

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Heat</strong>ing CableB100 & E100<strong>Heat</strong> Trace/FreezeProtection ThermostatsB100 / E100NEMA 4X• B100 Direct Mount for FreezeProtection (Ambient)(Models E121/122,B121 only)• E100 Remote Mount for <strong>Heat</strong>Trace (Bulb & Capillary)• 22 Amp Resistive Switch• Single <strong>and</strong> Dual Output Models• ± 1% Setpoint RepeatabilityB121 / E121NEMA 7• Fast Response for Protection ofValves <strong>and</strong> Piping• NEMA 4X, 7 <strong>and</strong> 9 EnclosuresApplications• E100• B100NEMA 4X Line or Pipe SensingNEMA 4X Ambient Air Sensing• E121/122/ NEMA 7 Line or Pipe Sensing122P• B121NEMA 7 Ambient Air SensingDescriptionMaintaining proper viscosity <strong>and</strong> fl ow is criticalin heat trace or freeze protection applications.The E100 remote mount thermostatsutilize a stainless steel bulb <strong>and</strong> capillarydesign to accurately sense temperature at keypoints along a pipe. The B100 direct mountthermostats feature liquid-fi lled thermal assemblies<strong>and</strong> sense air temperatures from 15Specificationsto 140˚F. Both models are epoxy coated to sealfrom moisture <strong>and</strong> contaminants in compliancewith NEMA 4X requirements. NEMA 7stats E121/122/122P <strong>and</strong> B121 are designedfor Class I, Division I <strong>and</strong> 2, Groups B, C, D,<strong>and</strong> Class 2, Division I <strong>and</strong> 2, Group E, F, G.Ambient Temperature Limits -40˚ to +160˚F (B100); -58˚F to +160˚F (B121, B122,E122, E121) (-40 to +71˚C); set point typically shiftsWARNING: Hazard of Fire. These devicesfunction as temperature controls only.Because they do not fail-safe, an approvedtemperature <strong>and</strong>/or pressure safety controlmust be used for safe operation.Switch OutputElectrical RatingWeightElectrical ConnectionTemperature AssemblyFillTemperature Deadb<strong>and</strong>One SPDT (types B100, E100, B121, E121); two SPDT(types E122, E122P)22 Amps 125/250/480 Vac resistiveTypes B100, E100: 1 lb., 8 oz (0,68 kg)Types B121, E121, E122, E122P: 3 lbs.,10 oz (1,6 kg.)Types E121, E122, E122P, B121: terminal block;Types B100, E100: direct to swtichTypes E100, E121, E122, E122P: 10 feet stainless steelbulb <strong>and</strong> capillaryTypes B100, B121: immersion stemNon-toxic oil fi lledTypically 2% of rangeBulb Dimensions (E100, E121, E122) Length 11-5/8", OD 1/8"(B100, B121) Length 2-11/16”, OD 9/16”140

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!