<strong>Fire</strong> <strong>Alarm</strong> <strong>Cables</strong>is one of the original and leadingmanufactures or <strong>Fire</strong> <strong>Alarm</strong> cables in the world.Security and <strong>Alarm</strong> cables are a vital part of thebuilding and construction industries.Security and <strong>Fire</strong><strong>Alarm</strong> cables have been oneof the most trusted names in the Security industry.For more detailed information on our fire alarmcables, contact our Customer Service Department at, or e-mail us at:. Information can alsobe found on our website:EVAC (Emergency Voice/<strong>Alarm</strong> Communication) systems are employed inlarge commercial buildings where in the event of a fire or other emergencymessages will warn occupants of the emergency and, if necessary, guidethe occupants out of the building in a timely and orderly way.To do this, EVAC systems must remain operational longer than a total evacuation scenarioor, as defined by code, for two hours.CI vs. CIC <strong>Cables</strong>:CI cables have been tested to pass the 2 hour UL2196 Flame Testnot in conduit. CI cables can not be deployed into conduit and passthe 2 hour flame test, therefore they are riser rated.CIC cables have been tested to pass the 2 hour Flame Test in Conduit,therefore can be placed in a Plenum space. CIC cables cannot be deployedin a 2 hour application outside the conduit.


<strong>Fire</strong> <strong>Alarm</strong> <strong>Cables</strong>Circuit Integrity in Conduit/ Shielded(CIC) - Riser RatedApplications:Indoor for:• Circuit Integrity• <strong>Fire</strong> <strong>Alarm</strong> Circuit Integrity• Survivability• Survivability from attack by fireStandard spool size 1000ft.CatalogNo.No. ofCond.5200FZ 25220FZ 25222FZ 45100FZ 25120FZ 25000FZ 2ConductorType &Nom. D.C.R16 AWG7x244.0 Ω/Mft16 AWGSolid4.0 Ω/Mft16 AWGSolid4.0 Ω/Mft14 AWG7x222.5 Ω/Mft14 AWGSolid2.5 Ω/Mft12 AWG7x201.6 Ω/MftInsulationType &ThicknessShielding&% CoverageJacket Type Nom.& Thickness O.D.Inches Inches InchesCSR.035CSR.035CSR.035CSR.035CSR.035CSR.035Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)Insulation • Twisted pair or cabled construction • Overall shield100% coverage of aluminum polyester foil with TCdrain wire • Overall FRPE Low-Smoke, Non-Halogen JacketRating:• NEC Type FPLR• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL1666,UL2196 - 2 Hour Flame Test ( in conduit only)Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%FRPE.056FRPE.056FRPE.056FRPE.056FRPE.056FRPE.056NECTypeNom.CapacitanceJacketColor.37 22pf/ft* Red.36 20pf/ft* Red.41 16pf/ft* Red.41 26pf/ft* Red.38 23pf/ft* Red.44 27pf/ft* Red* Capacitance between conductors.All<strong>Cables</strong>Color CodeBlack, Red- 4 or more are Blackand numberedJACKET: RedSpecial Notes:• CSR- Ceramifiable Silicon Rubber• FRPE- Flame Retardant Polyethylene


Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)Insulation • Twisted pair or cabled construction• Overall FRPE Low-Smoke, Non-Halogen JacketRating:• NEC Type FPLR• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL 1666,UL2196 - Two Hour Flame Test ( in conduit only)CatalogNo.No. ofCond.5200UZ 25220UZ 25100UZ 25120UZ 2ConductorType &Nom. D.C.R16 AWG7x244.0 Ω/Mft16 AWGSolid4.0 Ω/Mft14 AWG7x222.5 Ω/Mft14 AWGSolid2.5 Ω/Mft<strong>Fire</strong> <strong>Alarm</strong> <strong>Cables</strong>InsulationType &ThicknessShielding Jacket Type& ThicknessNom.O.D.Inches Inches InchesCSR.035CSR.035CSR.035CSR.035NoneNoneNoneNoneCircuit Integrity in Conduit/ UnshieldedRiser Rated - (CIC)FRPE.056FRPE.056FRPE.056FRPE.056Standard spool size 1000ft.NECTypeApplications:Indoor for:• Circuit Integrity• <strong>Fire</strong> <strong>Alarm</strong> Circuit Integrity• Survivability• Survivability from attack by fireNom.CapacitanceJacketColor.37 16pf/ft* Red.35 15pf/ft* Red.40 18pf/ft* Red.38 17pf/ft* Red* Capacitance between conductors.Special Notes:• CSR- Ceramifiable Silicon Rubber• FRPE- Flame Retardant PolyethyleneAll<strong>Cables</strong>Color CodeBlack, RedJACKET: Red


Circuit Integrity/ Shielded(CI) - Riser Rated<strong>Fire</strong> <strong>Alarm</strong> <strong>Cables</strong>Applications:Indoor for:• Circuit Integrity• <strong>Fire</strong> <strong>Alarm</strong> Circuit Integrity• Survivability• Survivability from attack by fireStandard spool size 1000ft.CatalogNo.No. ofCond.5320FM 25322FM 45300FM 25302FM 45220FM 25222FM 45200FM 25120FM 25122FM 45100FM 25020FM 25022FM 4Notes: Color Code Pg. 60ConductorType &Nom. D.C.R18 AWGSolid5.9 Ω/Mft18 AWGSolid5.9 Ω/Mft18 AWG7x265.9 Ω/Mft18 AWG7x265.9 Ω/Mft16 AWGSolid4.0 Ω/Mft16 AWGSolid4.0 Ω/Mft16 AWG7x244.0 Ω/Mft14 AWGSolid2.5 Ω/Mft14 AWGSolid2.5 Ω/Mft14 AWG7x222.5 Ω/Mft12 AWGSolid1.6 Ω/Mft12 AWGSolid1.6 Ω/MftInsulationType &ThicknessShielding&% CoveragJacket Type Nom.& Thickness O.D.Inches Inches InchesCSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034CSR.034Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Al. Foil100%Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)Insulation • Twisted pair or cabled construction• Overall shield 100% coverage of aluminum polyester foil withTC drain wire • Overall FRPE Low-Smoke, Non Halogen JacketRating:• NEC Type FPLR-CI• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL1666, UL2196 - 2 Hour Flame TestFRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045FRPE.045NECTypeNom.CapacitanceJacketColor.31 -CI 27pf/ft* Red.36 -CI 27pf/ft* Red.32 -CI 27pf/ft* Red.37 -CI 27pf/ft* Red.33 -CI 31pf/ft* Red.38 -CI 31pf/ft* Red.35 -CI 31pf/ft* Red.36 -CI 33pf/ft* Red.41 -CI 33pf/ft* Red.38 -CI 33pf/ft* Red.39 -CI37pf/ft*Red.46 -CI 37pf/ft* Red* Capacitance between conductors.


<strong>Fire</strong> <strong>Alarm</strong> <strong>Cables</strong>Description:• ASTM bare copper • Ceramifiable Silicon Rubber (CSR)Insulation • Twisted pair or cabled construction• Overall FRPE Low-Smoke, Non-Halogen JacketRating:• NEC Type FPLR-CI• (UL) Listed• Meets 300V requirements as specified in the NEC - 105°C• Flame Rating: UL 1666, UL2196- Two Hour Flame TestCatalogNo.No. ofCond.5320UM 25322UM 4ConductorType &Nom. D.C.R18 AWGSolid5.9 Ω/Mft18 AWGSolid5.9 Ω/MftInsulationType &ThicknessShielding Jacket Type& ThicknessNom.O.D.Inches Inches InchesCSR.034CSR.034NoneNoneFRPE.045FRPE.045Circuit Integrity / UnshieldedRiser Rated - (CI)NECTypeApplications:Indoor for:• Circuit Integrity• <strong>Fire</strong> <strong>Alarm</strong> Circuit Integrity• Survivability• Survivability from attack by fireStandard spool size 1000ft.Nom.CapacitanceJacketColor.31 -CI 17pf/ft* Red.35 -CI 17pf/ft* Red5220UM 216 AWGSolid4.0 Ω/MftCSR.034NoneFRPE.045.33 -CI 19pf/ft* Red5222UM 416 AWGSolid4.0 Ω/MftCSR.034NoneFRPE.045.38 -CI 19pf/ft* Red5120UM 214 AWGSolid2.5 Ω/MftCSR.034NoneFRPE.045.36 -CI 21pf/ft* Red5122UM 414 AWGSolid2.5 Ω/MftCSR.034NoneFRPE.045.41 -CI 21pf/ft* Red5020UM 212 AWGSolid1.6 Ω/MftCSR.034NoneFRPE.045.39 -CI 23pf/ft* Red5022UM 412 AWGSolid1.6 Ω/MftCSR.034NoneFRPE.045.45 -CI 23pf/ft* Red* Capacitance between conductors.Special Notes:• CSR- Ceramifiable Silicon Rubber• FRPE- Flame Retardant PolyethyleneAll<strong>Cables</strong>Color CodeBlack, Red- 4 or more are Blackand numberedJACKET: Red