18. Controller – An aluminum or steel rectangular box with a 6 in. finned heat sink on the sideof the box <strong>and</strong> a number of sockets for electrical <strong>and</strong> computer connections.19. Blowers -– Devices attached to the <strong>Prover</strong> cart, responsible for producing a source ofairflow during <strong>Prover</strong> testing.20. Master <strong>Meter</strong>(s) – <strong>The</strong> reference meter (tertiary st<strong>and</strong>ard) with known performancecharacteristics that is traceable to national <strong>and</strong> international st<strong>and</strong>ards. <strong>The</strong> <strong>Prover</strong> may bepurchased with one or two Master <strong>Meter</strong>s.21. Master <strong>Meter</strong> Cable – A cable containing a 6-pin connector at each end.22. Master <strong>Meter</strong> Junction Box – A rectangular box mounted to the end cover of theMaster <strong>Meter</strong>(s).23. Throttle <strong>Valve</strong> – An electrical actuator used to aid in the flow rate control for the prover.1.4 Optional Accessories:• Optical Scanner• ROOTS 8C <strong>Meter</strong> Test Hardware Assembly• ROOTS Series B3 Field CTR Pulser (MTR must be “Pulser Ready”)• Acoustic Filter• Inverter• 3" Quick-disconnect Connector (Female)• 3" Quick-disconnect Connector (Male)• SmartProve Cable• USB Serial Port Converter Kit1.5 <strong>The</strong>ory of Operation<strong>The</strong> <strong>Prover</strong> operates as a transfer test. <strong>The</strong> meter under test (Field <strong>Meter</strong>) registers volume <strong>and</strong> comparesit to the volume registered by a Master <strong>Meter</strong>. Blowers are used to pull a vacuum, which draws ambientair into the Field <strong>Meter</strong> <strong>and</strong> through a connecting hose directly into the Master <strong>Meter</strong>.In the normal test set-up, the mass of air passes through the meter under test <strong>and</strong> then through the Master<strong>Meter</strong>. Since the Master <strong>Meter</strong>’s characteristics are known, the meter under test can be characterized basedon the difference in its performance parameters as compared to the Master <strong>Meter</strong>. This difference inperformance is expressed in terms of accuracy (proof <strong>and</strong> percent error are also displayed).1.6 Precautions• No copies of this disk or any of the information contained there on shall be usedfor any purpose other than to operate the <strong>Model</strong> 5 ROOTS <strong>Prover</strong>.• Do not operate the <strong>Model</strong> 5 ROOTS <strong>Prover</strong> in the presence of flammable gas oran explosion may result.• Do not operate the <strong>Model</strong> 5 ROOTS <strong>Prover</strong> in the rain or while st<strong>and</strong>ing in waterin order to avoid a potential electrical shock.• Check upstream <strong>and</strong> downstream blocking or bypass valves to ensure that they operateproperly <strong>and</strong> are leak tight in the closed position before powering any device.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!