11.07.2015 Views

Varian 1200L LC/MS GC/MS - Agilent Technologies

Varian 1200L LC/MS GC/MS - Agilent Technologies

Varian 1200L LC/MS GC/MS - Agilent Technologies

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ammonia, Anhydrous (CAS Number 7664-41-7)Anhydrous Ammonia gas is highly toxic. Inhalation may cause irritation to eyes andthroat and may cause pulmonary edema, which can result in serious injury or death.Repeated exposure to Anhydrous Ammonia may cause permanent lung damage.• Refer to Material Safety Data Sheet (<strong>MS</strong>DS) for Anhydrous Ammonia forexposure control/personal protection, handling/storage, accidental release,first aid, and fire fighting measure requirements.• Anhydrous Ammonia should only be used in conjunction with an appropriateventilation system for the instrument, the exhaust from the foreline pump, andthe gas cylinder. Use appropriate safety shutoff valves for the AnhydrousAmmonia supply and interconnecting lines.The operator is responsible for determining and implementing appropriate precautionswhen using Anhydrous Ammonia and for compliance with all governmentalregulations. It is the operator's responsibility to understand and adhere to all safelaboratory practices concerning the use of toxic gases, including Anhydrous Ammonia.CID Gas (Triple Quad only)Argon is recommended for use as a Collision Induced Dissociation gas for <strong>MS</strong>/<strong>MS</strong> in the triplequadrupole <strong>MS</strong>, with a typical flow rate of 1 mL/min. The argon must have a purity of greaterthan 99%, and be regulated to 1−3 psi (0.1−0.2 bar).<strong>GC</strong> Carrier GasHeliumHelium is required as a carrier gas for the <strong>GC</strong>, with a minimum 99.999% ultra-high purity, andless than 1.0 ppm each of water, oxygen, and total hydrocarbons. The minimum requirement isone 257 ft 3 tank with an Alltech regulator #AL8111, or equivalent tank and regulator.The presence of greater than 1 ppm oxygen or water in the carrier gas supply maysignificantly affect the performance of the 1200 <strong>GC</strong>/<strong>MS</strong>. It may also damage suchcomponents as the capillary column, filaments, and multiplier. <strong>Varian</strong> recommends thatyou verify that your gas suppliers use controlled tanks to ensure that purity standardsare maintained. If you purchase pure gases in contaminated tanks, you may end up witha contaminated system requiring costly and time-consuming repair.FilterUse of a carrier gas filter is required for optimum performance and to protect your system frompotential contamination. Your <strong>GC</strong> Accessory Kit includes a <strong>GC</strong>/<strong>MS</strong> Gas Clean Oxygen/Moisturefilter (part number CP-17973) and filter base. This easy-to-remove gas filter cartridge combinesthree highly adsorptive materials in one filter to remove water, oxygen, and organic compoundsto purify the <strong>GC</strong>/<strong>MS</strong> gas. Carrier gas filters should be installed in a location where the indicatoris visible. The filter should be replaced when the indicator shows that the filter is saturated, orafter one year of service. For replacement procedures, refer to the instructions enclosed withyour filter.03-914961-00:6 17 of 24 1200/<strong>1200L</strong> <strong>MS</strong> Pre-installation Instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!