Table 4 <strong>1200L</strong> <strong>GC</strong>/<strong>LC</strong>/<strong>MS</strong> Power RequirementsInstrumentMax Current Draw100-115V (Amps)Max Current Draw200-240V (Amps)CP-3800 Gas Chromatograph 20 10ProStar 210/215 Pumps 2.25 each 1.125 eachProStar 430 AutoSampler 2 1<strong>1200L</strong> Mass Spectrometer 12 6602 Foreline pumps Not recommended 20Computer 3 1.5Monitor 3 1.5Printer 3 1.5NOTE: See Appendix 2 for complete current supply requirements for the standard modules.The power cable from the mass spectrometer is approximately 98 in. (2.5m) long and fitted withNational Electronics Manufacturers Association (NEMA) 5-15P power plugs. The NEMA 5-15Ppower plug and corresponding outlet are shown in Appendix 3 Figure 5(b). NEMA 5-15P plugsare rated at 15A and 120 Vac.The power cable from the foreline pump box for the <strong>LC</strong>/<strong>MS</strong> is approximately 78 in. (2m) longfitted with a National Electronics Manufacturers Association (NEMA) 6-20P power plug. TheNEMA 6-20P plugs are rated at 20A and 220 Vac. The NEMA 6-20P plug and correspondingoutlet are shown in Appendix 3 Figure 5(d).The power cable from the <strong>GC</strong> is approximately 78 in. (2m) long and fitted with NationalElectronics Manufacturers Association (NEMA) 5-20P power plugs. The NEMA 5-20P powerplug and corresponding outlet are shown in Appendix 3 Figure 5(a). NEMA 5-20P plugs arerated at 20A and 120 Vac.The power cables for the computer, monitor, and printer are approximately 78 in. (2m) long.They are fitted with NEMA 5-15P plugs.Systems shipped outside the United States and Canada are fitted with CEE 7/7 plugs which arerated at 16A and 230 Vac. The CEE 7/7 plug and outlet are shown in Appendix 3 Figure 5(c).Gas Requirements <strong>1200L</strong> <strong>GC</strong>/<strong>LC</strong>/<strong>MS</strong>NitrogenA Nitrogen gas supply capable of providing up to 12L/min of gas regulated at 80 psi is requiredas a nebulizing and drying gas. The nitrogen must have a purity greater than 99%, with lessthan 0.1 ppm hydrocarbons, and less than 1% oxygen. The nitrogen should be dry, with a −40degree dew point. <strong>Varian</strong> recommends the use of a nitrogen generator, or liquid nitrogen blowoffto supply the gas. All nitrogen generators require regular maintenance to continue to performto specification. The nitrogen generator manufacturer should be consulted as to preventativemaintenance requirements of the instrument, and the schedule must be followed. Any problemswith the <strong>MS</strong> that are found to be caused by poor gas quality are not covered under Warranty. Itis the customer’s responsibility to conform to all regulations regarding the installation andoperation of the gas system.03-914961-00:6 15 of 24 1200/<strong>1200L</strong> <strong>MS</strong> Pre-installation Instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!