9-6 Technical <strong>SIL2</strong> Requirements for the Application ProgramChang<strong>in</strong>g YourApplication ProgramThe follow<strong>in</strong>g rules apply to chang<strong>in</strong>g your application program <strong>in</strong>RSLogix 5000:• Program edits are not re<strong>com</strong>mended. However, they arepossible if necessary and should be limited. For example, m<strong>in</strong>orchanges such as chang<strong>in</strong>g a timer preset or analog setpo<strong>in</strong>tare possible.• Only authorized, specially-tra<strong>in</strong>ed personnel can make programedits. These personnel should use all supervisory methodsavailable, for example, us<strong>in</strong>g the controller keyswitch andsoftware password protections.• When authorized, specially-tra<strong>in</strong>ed personnel make programedits, they assume the central safety responsibility while thechanges are <strong>in</strong> progress. These personnel must also ma<strong>in</strong>ta<strong>in</strong>safe application operation.• Prior to mak<strong>in</strong>g any program edits, an impact analysis must beperformed by follow<strong>in</strong>g the specification and other lifecyclesteps described <strong>in</strong> Figure 9.1 as if the edits were an entirelynew program.• Users must sufficiently document all program edits, <strong>in</strong>clud<strong>in</strong>g:– authorization– impact analysis– execution– test <strong>in</strong>formation– revision <strong>in</strong>formation• Users cannot make program edits while the program is onl<strong>in</strong>e ifthe changes prevent the system from execut<strong>in</strong>g the safetyfunction or if alternative protection methods are not <strong>in</strong> place.• Users cannot edit their program from multiple programm<strong>in</strong>gterm<strong>in</strong>als simultaneously.• Changes to the SIS application software, <strong>in</strong> thiscase--RSLogix 5000, must <strong>com</strong>ply with IEC 61511 standard onprocess safety section 11.7.1 Operator Interface requirements.• Users cannot edit their program when a project is operat<strong>in</strong>g <strong>in</strong>the RUN state. In other words, if an application is runn<strong>in</strong>g andthe <strong>ControlLogix</strong> controller keyswitch is <strong>in</strong> the RUN position,users cannot make onl<strong>in</strong>e edits.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!