11.07.2015 Views

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-6 General Requirements for Application SoftwareChecklist for the Creation ofan Application ProgramThe follow<strong>in</strong>g checklist is re<strong>com</strong>mended to ma<strong>in</strong>ta<strong>in</strong> safety technicalaspects when programm<strong>in</strong>g, before and after load<strong>in</strong>g the new ormodified program.Company:Checklist for Creation of an Application ProgramSafety Manual <strong>ControlLogix</strong> SystemSite:Project def<strong>in</strong>ition:File def<strong>in</strong>ition / Archive number:Notes / Checks Yes No CommentBefore a ModificationAre the configuration of the <strong>ControlLogix</strong> system and theapplication program created on the basis of safety aspects?Are programm<strong>in</strong>g guidel<strong>in</strong>es used for the creation of theapplication program?After a Modification - Before Load<strong>in</strong>gHas a review of the application program with regard to theb<strong>in</strong>d<strong>in</strong>g system specification been carried out by a person not<strong>in</strong>volved <strong>in</strong> the program creation?Has the result of the review been documented and released(date/signature)?Was a backup of the <strong>com</strong>plete program created before load<strong>in</strong>g aprogram <strong>in</strong> the <strong>ControlLogix</strong> system?After a Modification - After Load<strong>in</strong>gWas a sufficient number of tests carried out for the safetyrelevant logical l<strong>in</strong>k<strong>in</strong>g (<strong>in</strong>clud<strong>in</strong>g I/O) and for all mathematicalcalculations?Was all force <strong>in</strong>formation reset before safety operation?Has it been verified that the system is operat<strong>in</strong>g properly?Have the appropriate security rout<strong>in</strong>es and functions been<strong>in</strong>stalled?Is the controller keyswitch <strong>in</strong> Run mode and the key removed?Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!