11.07.2015 Views

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ControlLogix</strong> I/O Modules 6-21• Choose Float<strong>in</strong>g Po<strong>in</strong>t Data Format Dur<strong>in</strong>g ModuleConfiguration: <strong>ControlLogix</strong> analog output modules perform ahost of on-board alarm process<strong>in</strong>g to validate that the outputsignal is with<strong>in</strong> the proper range for the application. However,these features are only available <strong>in</strong> Float<strong>in</strong>g Po<strong>in</strong>t mode.• Exam<strong>in</strong>e the Appropriate Module Fault, Channel Fault andChannel Status Bits to Initiate Fault Rout<strong>in</strong>es: Each modulewill <strong>com</strong>municate the operat<strong>in</strong>g status of each channel to thecontroller dur<strong>in</strong>g normal operation. Application logic mustexam<strong>in</strong>e the appropriate bits to <strong>in</strong>itiate a fault rout<strong>in</strong>e for a givenapplication. For more <strong>in</strong>formation on faults, see Chapter 7,Faults <strong>in</strong> the <strong>ControlLogix</strong> System.• For typical emergency shutdown (ESD) applicationsoutputs must be configured to De-energize: Whenconfigur<strong>in</strong>g any <strong>ControlLogix</strong> output module, each output mustbe configured to de-energize <strong>in</strong> the event of a fault and <strong>in</strong> theevent of the controller go<strong>in</strong>g <strong>in</strong>to program mode. For exceptionsto the typical ESD applications, see Chapter 1, SIL Policy.• Wire Output Back to Input and Exam<strong>in</strong>ation of OutputData Echo signal: Users must wire an analog output to anactuator and then back to an analog <strong>in</strong>put to monitor theoutput’s performance, as shown <strong>in</strong> Figure 6.17. The applicationlogic must exam<strong>in</strong>e the Data Echo value associated with eachoutput po<strong>in</strong>t to make sure that the requested output <strong>com</strong>mandfrom the controller was received by the module. The value mustbe <strong>com</strong>pared to the analog <strong>in</strong>put that is monitor<strong>in</strong>g the output tomake sure the value is <strong>in</strong> an acceptable range for theapplication.In the ladder diagram <strong>in</strong> Figure 6.16, a user-def<strong>in</strong>ed percentageof acceptable deviation (that is, tolerance) is applied to theconfigured range of the analog <strong>in</strong>put and output (that is, range)and the result is stored (that is, delta). This delta value is thenadded to and subtracted from the monitor<strong>in</strong>g analog <strong>in</strong>putchannel; the results def<strong>in</strong>e an acceptable High and Low limit ofdeviation. The analog Output Echo is then <strong>com</strong>pared to theselimits to determ<strong>in</strong>e if the output are work<strong>in</strong>g properly.The output’s OK bit preconditions a Timer run that is preset toac<strong>com</strong>modate an acceptable fault response time and any<strong>com</strong>munication filter<strong>in</strong>g, or output, lags <strong>in</strong> the system. If themonitor<strong>in</strong>g <strong>in</strong>put value and the Output Echo mis<strong>com</strong>pare forlonger than the preset value, a fault is registered with acorrespond<strong>in</strong>g alarm.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!