1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6-20 <strong>ControlLogix</strong> I/O Modules<strong>Us<strong>in</strong>g</strong> Analog OutputModulesThe <strong>1756</strong>-OF8 <strong>ControlLogix</strong> analog output module is certified for use<strong>SIL2</strong> applications.General Considerations when us<strong>in</strong>g Any <strong>ControlLogix</strong> AnalogOutput ModuleThere are a number of general application considerations that youmust follow when apply<strong>in</strong>g the analog output modules <strong>in</strong> a <strong>SIL2</strong>application:• Proof Tests - Periodically (for example, once every severalyears) a System Validation test must be performed. Manually, orautomatically, test outputs to make sure that all outputs areoperational. Channel data should be varied over the fulloperat<strong>in</strong>g range to make sure that the correspond<strong>in</strong>g field signallevels vary accord<strong>in</strong>gly. For additional <strong>in</strong>formation on ProofTests, see page 1-5 and Figure 9.1 on page 9-5.• Calibrate Outputs Periodically, As Necessary: <strong>ControlLogix</strong>I/O modules ship from the factory with a highly accurate levelof calibration. However, because each application is different,users are responsible for mak<strong>in</strong>g sure their <strong>ControlLogix</strong> I/Omodules are properly calibrated for their specific application.Users can employ tests <strong>in</strong> application program logic todeterm<strong>in</strong>e when a module requires recalibration. For example,to determ<strong>in</strong>e whether an output module needs to berecalibrated, a user can determ<strong>in</strong>e a tolerance band of accuracyfor a specific application. The user can then measure outputvalues on multiple channels and <strong>com</strong>pare those values toacceptable values with<strong>in</strong> the tolerance band. Based on thedifferences <strong>in</strong> the <strong>com</strong>parison, the user could then determ<strong>in</strong>ewhether recalibration is necessary.Calibration (and subsequent recalibration) is not a safety issue.However, we re<strong>com</strong>mend that each analog output be calibratedat least every 3 years to verify the accuracy of the <strong>in</strong>put signaland avoid nuisance application shutdowns.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!