Summary of Changes 2Notes:Publication 1756-RM001B-EN-P - October 2003

PrefaceIntroductionThis application manual is intended to describe the ControlLogixControl System components available from Rockwell Automation thatare suitable for use in SIL2 applications.Manual Set-UpThis manual is designed to make clear how the ControlLogix ControlSystem can be SIL2-certified. Table Preface.1 lists the informationavailable in each section.Table Preface.1Section: Title: Description:Chapter 1 SIL Policy Introduction to the SIL policy and how thatpolicy relates to the ControlLogix system.Chapter 2 The ControlLogix System Brief overview of all the components present inthe SIL2-certified ControlLogix system.Chapter 3 ControlLogix SystemHardwareDescription of the ControlLogix power suppliesand chassis used in the SIL2-certifiedControlLogix system.Chapter 4 ControlLogix Controller Description of the ControlLogix controller usedin the SIL2-certified ControlLogix system.Chapter 5ControlLogix CommunicationsModulesDescription of the ControlLogix communicationsmodules used in the SIL2-certified ControlLogixsystem.Chapter 6 ControlLogix I/O Modules Description of the ControlLogix I/O modulesused in the SIL2-certified ControlLogix system.Chapter 7Chapter 8Chapter 9Chapter 10Appendix AAppendix BFaults in the ControlLogixSystemGeneral Requirements forApplication SoftwareTechnical SIL2 Requirementsfor the Application ProgramUse and Application ofHuman to Machine InterfacesResponse Times inControlLogixSystem Self-Testing andUser-Programmed ResponsesDescription of two common conditions thatcause a fault in a ControlLogix system.Guidelines for application development inRSLogix 5000 as they relate to SIL2.Description of technical safety necessary inSIL2-certified ControlLogix applications.Description of the precautions and techniquesthat should be used with HMI devices as theyare used in SIL2-certified ControlLogixapplications.Additional information on the componentspresent in a SIL2-certified ControlLogixapplication.Explanation of the self-testing and systemresponses to test results that are available inthe ControlLogix system.1 Publication 1756-RM001B-EN-P - October 2003

PrefaceIntroductionThis application manual is <strong>in</strong>tended to describe the <strong>ControlLogix</strong>Control System <strong>com</strong>ponents available from Rockwell Automation thatare suitable for use <strong>in</strong> <strong>SIL2</strong> applications.Manual Set-UpThis manual is designed to make clear how the <strong>ControlLogix</strong> ControlSystem can be <strong>SIL2</strong>-certified. Table Preface.1 lists the <strong>in</strong>formationavailable <strong>in</strong> each section.Table Preface.1Section: Title: Description:Chapter 1 SIL Policy Introduction to the SIL policy and how thatpolicy relates to the <strong>ControlLogix</strong> system.Chapter 2 The <strong>ControlLogix</strong> System Brief overview of all the <strong>com</strong>ponents present <strong>in</strong>the <strong>SIL2</strong>-certified <strong>ControlLogix</strong> system.Chapter 3 <strong>ControlLogix</strong> SystemHardwareDescription of the <strong>ControlLogix</strong> power suppliesand chassis used <strong>in</strong> the <strong>SIL2</strong>-certified<strong>ControlLogix</strong> system.Chapter 4 <strong>ControlLogix</strong> Controller Description of the <strong>ControlLogix</strong> controller used<strong>in</strong> the <strong>SIL2</strong>-certified <strong>ControlLogix</strong> system.Chapter 5<strong>ControlLogix</strong> CommunicationsModulesDescription of the <strong>ControlLogix</strong> <strong>com</strong>municationsmodules used <strong>in</strong> the <strong>SIL2</strong>-certified <strong>ControlLogix</strong>system.Chapter 6 <strong>ControlLogix</strong> I/O Modules Description of the <strong>ControlLogix</strong> I/O modulesused <strong>in</strong> the <strong>SIL2</strong>-certified <strong>ControlLogix</strong> system.Chapter 7Chapter 8Chapter 9Chapter 10Appendix AAppendix BFaults <strong>in</strong> the <strong>ControlLogix</strong>SystemGeneral Requirements forApplication SoftwareTechnical <strong>SIL2</strong> Requirementsfor the Application ProgramUse and Application ofHuman to Mach<strong>in</strong>e InterfacesResponse Times <strong>in</strong><strong>ControlLogix</strong>System Self-Test<strong>in</strong>g andUser-Programmed ResponsesDescription of two <strong>com</strong>mon conditions thatcause a fault <strong>in</strong> a <strong>ControlLogix</strong> system.Guidel<strong>in</strong>es for application development <strong>in</strong>RSLogix 5000 as they relate to <strong>SIL2</strong>.Description of technical safety necessary <strong>in</strong><strong>SIL2</strong>-certified <strong>ControlLogix</strong> applications.Description of the precautions and techniquesthat should be used with HMI devices as theyare used <strong>in</strong> <strong>SIL2</strong>-certified <strong>ControlLogix</strong>applications.Additional <strong>in</strong>formation on the <strong>com</strong>ponentspresent <strong>in</strong> a <strong>SIL2</strong>-certified <strong>ControlLogix</strong>application.Explanation of the self-test<strong>in</strong>g and systemresponses to test results that are available <strong>in</strong>the <strong>ControlLogix</strong> system.1 Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!