Summary of Changes 2Notes:Publication 1756-RM001B-EN-P - October 2003
PrefaceIntroductionThis application manual is intended to describe the ControlLogixControl System components available from Rockwell Automation thatare suitable for use in SIL2 applications.Manual Set-UpThis manual is designed to make clear how the ControlLogix ControlSystem can be SIL2-certified. Table Preface.1 lists the informationavailable in each section.Table Preface.1Section: Title: Description:Chapter 1 SIL Policy Introduction to the SIL policy and how thatpolicy relates to the ControlLogix system.Chapter 2 The ControlLogix System Brief overview of all the components present inthe SIL2-certified ControlLogix system.Chapter 3 ControlLogix SystemHardwareDescription of the ControlLogix power suppliesand chassis used in the SIL2-certifiedControlLogix system.Chapter 4 ControlLogix Controller Description of the ControlLogix controller usedin the SIL2-certified ControlLogix system.Chapter 5ControlLogix CommunicationsModulesDescription of the ControlLogix communicationsmodules used in the SIL2-certified ControlLogixsystem.Chapter 6 ControlLogix I/O Modules Description of the ControlLogix I/O modulesused in the SIL2-certified ControlLogix system.Chapter 7Chapter 8Chapter 9Chapter 10Appendix AAppendix BFaults in the ControlLogixSystemGeneral Requirements forApplication SoftwareTechnical SIL2 Requirementsfor the Application ProgramUse and Application ofHuman to Machine InterfacesResponse Times inControlLogixSystem Self-Testing andUser-Programmed ResponsesDescription of two common conditions thatcause a fault in a ControlLogix system.Guidelines for application development inRSLogix 5000 as they relate to SIL2.Description of technical safety necessary inSIL2-certified ControlLogix applications.Description of the precautions and techniquesthat should be used with HMI devices as theyare used in SIL2-certified ControlLogixapplications.Additional information on the componentspresent in a SIL2-certified ControlLogixapplication.Explanation of the self-testing and systemresponses to test results that are available inthe ControlLogix system.1 Publication 1756-RM001B-EN-P - October 2003
- Page 1: Using ControlLogixin SIL2 Applicati
- Page 6 and 7: Preface 2Table Preface.1Section: Ti
- Page 8 and 9: Table of Contents 2ControlLogix Com
- Page 10 and 11: Table of Contents 4Additional Infor
- Page 12 and 13: 1-2 SIL PolicyThe TUV Rheinland has
- Page 14 and 15: 1-4 SIL PolicySIL2 CertificationFig
- Page 16 and 17: 1-6 SIL PolicySIL2-Certified Contro
- Page 18 and 19: 1-8 SIL PolicyHardware Designs andF
- Page 20 and 21: 1-10 SIL PolicyCatalogNumberDescrip
- Page 22 and 23: 1-12 SIL PolicyCatalogNumberDescrip
- Page 24 and 25: 1-14 SIL PolicySIL ComplianceDistri
- Page 26 and 27: 1-16 SIL PolicyProgram Watchdog Tim
- Page 28 and 29: 2-2 The ControlLogix SystemIf an an
- Page 30 and 31: 2-4 The ControlLogix SystemData Ech
- Page 32 and 33: 2-6 The ControlLogix SystemSoftware
- Page 34 and 35: 2-8 The ControlLogix SystemNotes:Pu
- Page 36 and 37: 3-2 ControlLogix System HardwareCon
- Page 38 and 39: 3-4 ControlLogix System HardwareRec
- Page 40 and 41: 3-6 ControlLogix System HardwareNot
- Page 42 and 43: 4-2 ControlLogix ControllerRecommen
- Page 44 and 45: 5-2 ControlLogix Communications Mod
- Page 46 and 47: 5-4 ControlLogix Communications Mod
- Page 48 and 49: 6-2 ControlLogix I/O ModulesFigure
- Page 50 and 51: 6-4 ControlLogix I/O ModulesModule
- Page 52 and 53: 6-6 ControlLogix I/O ModulesWiring
Summary of Changes 2Notes:Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003