3-4 ControlLogix System HardwareRecommendations forSystem Hardware UseUsers must consider the recommendations listed below when usingSIL2-certified ControlLogix hardware:ChassisWhen installing ControlLogix chassis, follow the information providedin the product documentation listed in the Related ControlLogixHardware Documentation section on page 3-5.Power SuppliesUsers must consider these recommendations when using SIL2-certifiedControlLogix power supplies:• When installing ControlLogix power supplies, follow theinformation provided in the product documentation listed in theRelated ControlLogix Hardware Documentation section onpage 3-5.• A non-redundant power supply can be used if it meets theuser-defined PFD criteria.• For high availability SIL2 applications, the redundant powersupply is recommended.• It is recommended that the solid state fault relay on each powersupply be wired from an appropriate voltage source to an inputpoint in ControlLogix so the user can detect and display a powersupply fault.Publication 1756-RM001B-EN-P - October 2003

ControlLogix System Hardware 3-5Related ControlLogixHardware DocumentationFor more information on ControlLogix hardware, see the followingRockwell Automation publications:• ControlLogix Chassis Installation Instructions, publication1756-IN080• ControlLogix Non-Redundant Power Supplies InstallationInstructions, publication 1756-5.78• ControlLogix Redundant Power Supplies InstallationInstructions, publication 1756-IN573• ControlLogix Redundant Power Supply Chassis Adapter ModuleInstallation Instructions, publication 1756-IN574These publications are available from Rockwell Automation byvisiting:http://www.theautomationbookstore.comhttp://www.ab.com/manualsPublication 1756-RM001B-EN-P - October 2003

3-4 <strong>ControlLogix</strong> System HardwareRe<strong>com</strong>mendations forSystem Hardware UseUsers must consider the re<strong>com</strong>mendations listed below when us<strong>in</strong>g<strong>SIL2</strong>-certified <strong>ControlLogix</strong> hardware:ChassisWhen <strong>in</strong>stall<strong>in</strong>g <strong>ControlLogix</strong> chassis, follow the <strong>in</strong>formation provided<strong>in</strong> the product documentation listed <strong>in</strong> the Related <strong>ControlLogix</strong>Hardware Documentation section on page 3-5.Power SuppliesUsers must consider these re<strong>com</strong>mendations when us<strong>in</strong>g <strong>SIL2</strong>-certified<strong>ControlLogix</strong> power supplies:• When <strong>in</strong>stall<strong>in</strong>g <strong>ControlLogix</strong> power supplies, follow the<strong>in</strong>formation provided <strong>in</strong> the product documentation listed <strong>in</strong> theRelated <strong>ControlLogix</strong> Hardware Documentation section onpage 3-5.• A non-redundant power supply can be used if it meets theuser-def<strong>in</strong>ed PFD criteria.• For high availability <strong>SIL2</strong> applications, the redundant powersupply is re<strong>com</strong>mended.• It is re<strong>com</strong>mended that the solid state fault relay on each powersupply be wired from an appropriate voltage source to an <strong>in</strong>putpo<strong>in</strong>t <strong>in</strong> <strong>ControlLogix</strong> so the user can detect and display a powersupply fault.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!