3-4 ControlLogix System HardwareRecommendations forSystem Hardware UseUsers must consider the recommendations listed below when usingSIL2-certified ControlLogix hardware:ChassisWhen installing ControlLogix chassis, follow the information providedin the product documentation listed in the Related ControlLogixHardware Documentation section on page 3-5.Power SuppliesUsers must consider these recommendations when using SIL2-certifiedControlLogix power supplies:• When installing ControlLogix power supplies, follow theinformation provided in the product documentation listed in theRelated ControlLogix Hardware Documentation section onpage 3-5.• A non-redundant power supply can be used if it meets theuser-defined PFD criteria.• For high availability SIL2 applications, the redundant powersupply is recommended.• It is recommended that the solid state fault relay on each powersupply be wired from an appropriate voltage source to an inputpoint in ControlLogix so the user can detect and display a powersupply fault.Publication 1756-RM001B-EN-P - October 2003
ControlLogix System Hardware 3-5Related ControlLogixHardware DocumentationFor more information on ControlLogix hardware, see the followingRockwell Automation publications:• ControlLogix Chassis Installation Instructions, publication1756-IN080• ControlLogix Non-Redundant Power Supplies InstallationInstructions, publication 1756-5.78• ControlLogix Redundant Power Supplies InstallationInstructions, publication 1756-IN573• ControlLogix Redundant Power Supply Chassis Adapter ModuleInstallation Instructions, publication 1756-IN574These publications are available from Rockwell Automation byvisiting:http://www.theautomationbookstore.comhttp://www.ab.com/manualsPublication 1756-RM001B-EN-P - October 2003
- Page 1: Using ControlLogixin SIL2 Applicati
- Page 4 and 5: Summary of Changes 2Notes:Publicati
- Page 6 and 7: Preface 2Table Preface.1Section: Ti
- Page 8 and 9: Table of Contents 2ControlLogix Com
- Page 10 and 11: Table of Contents 4Additional Infor
- Page 12 and 13: 1-2 SIL PolicyThe TUV Rheinland has
- Page 14 and 15: 1-4 SIL PolicySIL2 CertificationFig
- Page 16 and 17: 1-6 SIL PolicySIL2-Certified Contro
- Page 18 and 19: 1-8 SIL PolicyHardware Designs andF
- Page 20 and 21: 1-10 SIL PolicyCatalogNumberDescrip
- Page 22 and 23: 1-12 SIL PolicyCatalogNumberDescrip
- Page 24 and 25: 1-14 SIL PolicySIL ComplianceDistri
- Page 26 and 27: 1-16 SIL PolicyProgram Watchdog Tim
- Page 28 and 29: 2-2 The ControlLogix SystemIf an an
- Page 30 and 31: 2-4 The ControlLogix SystemData Ech
- Page 32 and 33: 2-6 The ControlLogix SystemSoftware
- Page 34 and 35: 2-8 The ControlLogix SystemNotes:Pu
- Page 36 and 37: 3-2 ControlLogix System HardwareCon
- Page 40 and 41: 3-6 ControlLogix System HardwareNot
- Page 42 and 43: 4-2 ControlLogix ControllerRecommen
- Page 44 and 45: 5-2 ControlLogix Communications Mod
- Page 46 and 47: 5-4 ControlLogix Communications Mod
- Page 48 and 49: 6-2 ControlLogix I/O ModulesFigure
- Page 50 and 51: 6-4 ControlLogix I/O ModulesModule
- Page 52 and 53: 6-6 ControlLogix I/O ModulesWiring
- Page 54 and 55: 6-8 ControlLogix I/O ModulesGeneral
- Page 56 and 57: 6-10 ControlLogix I/O ModulesWiring
- Page 58 and 59: 6-12 ControlLogix I/O ModulesApplic
- Page 60 and 61: 6-14 ControlLogix I/O Modules• Ch
- Page 62 and 63: 6-16 ControlLogix I/O ModulesWiring
- Page 64 and 65: 6-18 ControlLogix I/O ModulesWiring
- Page 66 and 67: 6-20 ControlLogix I/O ModulesUsing
- Page 68 and 69: 6-22 ControlLogix I/O ModulesFigure
- Page 70 and 71: 6-24 ControlLogix I/O ModulesWiring
- Page 72 and 73: 6-26 ControlLogix I/O ModulesCheckl
- Page 74 and 75: 7-2 Faults in the ControlLogix Syst
- Page 76 and 77: 7-4 Faults in the ControlLogix Syst
- Page 78 and 79: 8-2 General Requirements for Applic
- Page 80 and 81: 8-4 General Requirements for Applic
- Page 82 and 83: 8-6 General Requirements for Applic
- Page 84 and 85: 9-2 Technical SIL2 Requirements for
- Page 86 and 87: 9-4 Technical SIL2 Requirements for
3-4 <strong>ControlLogix</strong> System HardwareRe<strong>com</strong>mendations forSystem Hardware UseUsers must consider the re<strong>com</strong>mendations listed below when us<strong>in</strong>g<strong>SIL2</strong>-certified <strong>ControlLogix</strong> hardware:ChassisWhen <strong>in</strong>stall<strong>in</strong>g <strong>ControlLogix</strong> chassis, follow the <strong>in</strong>formation provided<strong>in</strong> the product documentation listed <strong>in</strong> the Related <strong>ControlLogix</strong>Hardware Documentation section on page 3-5.Power SuppliesUsers must consider these re<strong>com</strong>mendations when us<strong>in</strong>g <strong>SIL2</strong>-certified<strong>ControlLogix</strong> power supplies:• When <strong>in</strong>stall<strong>in</strong>g <strong>ControlLogix</strong> power supplies, follow the<strong>in</strong>formation provided <strong>in</strong> the product documentation listed <strong>in</strong> theRelated <strong>ControlLogix</strong> Hardware Documentation section onpage 3-5.• A non-redundant power supply can be used if it meets theuser-def<strong>in</strong>ed PFD criteria.• For high availability <strong>SIL2</strong> applications, the redundant powersupply is re<strong>com</strong>mended.• It is re<strong>com</strong>mended that the solid state fault relay on each powersupply be wired from an appropriate voltage source to an <strong>in</strong>putpo<strong>in</strong>t <strong>in</strong> <strong>ControlLogix</strong> so the user can detect and display a powersupply fault.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003