11.07.2015 Views

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2-4 The <strong>ControlLogix</strong> SystemData Echo Communication CheckAnother powerful by-product of the p/c <strong>com</strong>munication model andthe implementation of the Control and Information Protocol (CIP)protocol is the Output Data Echo, a <strong>com</strong>munication methodemployed between owner-controllers and every output module <strong>in</strong> thesystem. Output Data Echo allows the user to verify that an ON/OFFoutput <strong>com</strong>mand from the controller was actually received by thecorrect output module, and that the module will attempt to executethe <strong>com</strong>mand to the field device connected to it.Dur<strong>in</strong>g normal operation, when a controller sends an output<strong>com</strong>mand, the output module that is targeted for that <strong>com</strong>mand will“echo” that requested state back to the system upon its receipt. Thisverifies that the module has received the <strong>com</strong>mand and will try toexecute it. By <strong>com</strong>par<strong>in</strong>g the requested state from the controller to theData Echo received from the module, the user can validate that thesignal has reached the correct module and that the module willattempt to activate the appropriate field-side device. Aga<strong>in</strong>, it is theuser’s responsibility to establish the course of action appropriate totheir safety application.When used with standard <strong>ControlLogix</strong> output modules, the DataEcho validates the <strong>com</strong>mand up to the system-side of the module, butnot to the field-side. However, when this feature is used <strong>in</strong> tandemwith diagnostic output modules, the user can virtually verify theoutput <strong>com</strong>mand <strong>in</strong>tegrity from the controller to the actuatorconnected to the module.Diagnostic output modules conta<strong>in</strong> special circuitry that performsField Side Output Verification. Field Side Output Verification<strong>in</strong>forms the user that system-side <strong>com</strong>mands received by the moduleare accurately represented on the power side of the switch<strong>in</strong>g device.In other words, for each output po<strong>in</strong>t, this feature confirms that theoutput is ON when it is <strong>com</strong>manded to be ON or OFF when<strong>com</strong>manded to be OFF.The capability of <strong>com</strong>par<strong>in</strong>g the actual state of the field-side of thediagnostic module’s output aga<strong>in</strong>st what the controller <strong>com</strong>mandsgives the user the ability to make sure that the module is perform<strong>in</strong>gwhat the control system is request<strong>in</strong>g, once that output <strong>com</strong>mand hasbeen issued.Publication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!