11.07.2015 Views

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

1756-RM001B-EN-P, Using ControlLogix in SIL2 ... - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1-12 SIL PolicyCatalogNumberDescription<strong>1756</strong>-A-- <strong>ControlLogix</strong> Chassis 40,143,919 (2)Table 1.4<strong>ControlLogix</strong> Product Probability of Undetected Dangerous Failure per HourMean Time λ (5) Calculated PFH:Between Failure(MTBF) (1) 1oo1 architecture 1oo2 architecture(average (3) )2.49E-081.25E-09<strong>1756</strong>-CNB ControlNet Bridge 3,596,087 (2) 2.78E-07 1.39E-08<strong>1756</strong>-CNBR Redundant ControlNet Bridge 3,385,813 (2) 2.95E-07 1.48E-08<strong>1756</strong>-IA16I AC Isolated Input 4,144,192 2.41E-07 1.74E-09<strong>1756</strong>-IA8D AC Diagnostic Input 3,856,320 2.59E-07 1.87E-09<strong>1756</strong>-IB16D DC Diagnostic Input 7,386,774 1.35E-07 9.63E-10<strong>1756</strong>-IB16I DC Isolated Input 3,562,624 2.81E-07 2.03E-09<strong>1756</strong>-IF8 Analog Input 1,690,694 5.91E-07 4.44E-09<strong>1756</strong>-IR6I RTD Input 3,456,960 2.89E-07 2.10E-09<strong>1756</strong>-IT6I Thermocouple Input 4,784,000 2.09E-07 1.50E-09<strong>1756</strong>-L55M16 <strong>ControlLogix</strong> 5555 Processor 2,855,348 (2) 3.50E-07 1.75E-08<strong>1756</strong>-OA16I AC Isolated Output 1,994,720 5.01E-07 3.72E-09<strong>1756</strong>-OA8D AC Diagnostic Output 3,839,680 2.60E-07 1.30E-08<strong>1756</strong>-OB16D DC Diagnostic Output 4,520,534 2.21E-07 1.11E-08<strong>1756</strong>-OB16I DC Isolated Output 1,703,520 5.87E-07 4.40E-09<strong>1756</strong>-OB8EI DC Fused Output 1,239,680 8.07E-07 6.20E-09<strong>1756</strong>-OF8 Analog Output 2,054,694 4.87E-07 3.61E-09<strong>1756</strong>-OX8I Contact Output 6,639,360 1.51E-07 1.07E-09<strong>1756</strong>-PA75 AC Power Supply 7,301,935 (2) 1.37E-07 6.85E-09<strong>1756</strong>-PA75R AC Redundant Power Supply 4,380,000,000 (2), (4) 2.28E-10 1.14E-11<strong>1756</strong>-PB75 DC Power Supply 7,100,760 (2) 1.41E-07 7.04E-09<strong>1756</strong>-PB75R DC Redundant Power Supply 4,380,000,000 (2), (4) 2.28E-10 1.14E-11<strong>1756</strong>-PSCA Power Supply Chassis Adapter 45,146,727 (2) 2.21E-08 1.11E-09(1) MTBF measured <strong>in</strong> hours.(2) Calculated us<strong>in</strong>g field-based values for <strong>com</strong>ponents.(3) Average = The arithmetic average of the MTBFs of all five Chassis (<strong>1756</strong>-A4, A7, A10, A13, and A17)(4)(5)Assumes that both power supplies fail simultaneously.λ = Failure Rate = 1/MTBFPublication <strong>1756</strong>-<strong>RM001B</strong>-<strong>EN</strong>-P - October 2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!