DATA SHEET - Glyn High-Tech Distribution

DATA SHEET - Glyn High-Tech Distribution DATA SHEET - Glyn High-Tech Distribution

11.07.2015 Views

HX8346-A(T)240RGBx320 dots, 262K color TFT controller driver7.8 Partial Area End Row Register (R0C~0Dh)DATA SHEET V01Figure 7. 13 Partial Area End Row Register Upper Byte (R0Ch)Figure 7. 14 Partial Area End Row Register Low Byte (R0Dh)These commands (R0Ah~~0Dh) define the partial mode’s display area. There are 4parameters associated with this command, PSL[15:0], PEL[15:0], as illustrated in thefigures below. PSL and PEL refer to the Frame Memory Line Pointer.7.9 Vertical Scroll Top Fixed Area Register (R0E~0Fh)Figure 7. 15 Vertical Scroll Top Fixed Area Register Upper Byte (R0Eh)Figure 7. 16 Vertical Scroll Top Fixed Area Register Low Byte (R0Fh)7.10 Vertical Scroll Height Area Register (R10~11h)Figure 7. 17 Vertical Scroll Height Area Register Upper Byte (R10h)Figure 7. 18 Vertical Scroll Height Area Register Low Byte (R11h)Himax ConfidentialThis information contained herein is the exclusive property of Himax and shall not be distributed, reproduced, or disclosedin whole or in part without prior written permission of Himax.-P.91-July, 2007

HX8346-A(T)240RGBx320 dots, 262K color TFT controller driverDATA SHEET V017.11 Vertical Scroll Button Fixed Area Register (R12~13h)Figure 7. 19 Vertical Scroll Button Fixed Area Register Upper Byte (R12h)Figure 7. 20 Vertical Scroll Button Fixed Area Register Low Byte (R13h)These commands (R0E~0Fh, R10~11h, R12~13h) define the Vertical Scrolling Areaof the display.7.12 Vertical Scroll Start Address Register (R14~15h)Figure 7. 21 Vertical Scroll Start Address Register Upper Byte (R14h)Figure 7. 22 Vertical Scroll Start Address Register Low Byte (R15h)This command is used together with Vertical Scrolling Definition (33h). These twocommands describe the scrolling area and the scrolling mode.The Vertical Scrolling Start Address command has one parameter which describes theaddress of the line in the Frame Memory that will be written as the first line after the last lineof the Top Fixed Area on the display.7.13 Memory Access Control Register (R16h)Figure 7. 23 Memory Access Control Register (R16h)Himax ConfidentialThis information contained herein is the exclusive property of Himax and shall not be distributed, reproduced, or disclosedin whole or in part without prior written permission of Himax.-P.92-July, 2007

HX8346-A(T)240RGBx320 dots, 262K color TFT controller driver7.8 Partial Area End Row Register (R0C~0Dh)<strong>DATA</strong> <strong>SHEET</strong> V01Figure 7. 13 Partial Area End Row Register Upper Byte (R0Ch)Figure 7. 14 Partial Area End Row Register Low Byte (R0Dh)These commands (R0Ah~~0Dh) define the partial mode’s display area. There are 4parameters associated with this command, PSL[15:0], PEL[15:0], as illustrated in thefigures below. PSL and PEL refer to the Frame Memory Line Pointer.7.9 Vertical Scroll Top Fixed Area Register (R0E~0Fh)Figure 7. 15 Vertical Scroll Top Fixed Area Register Upper Byte (R0Eh)Figure 7. 16 Vertical Scroll Top Fixed Area Register Low Byte (R0Fh)7.10 Vertical Scroll Height Area Register (R10~11h)Figure 7. 17 Vertical Scroll Height Area Register Upper Byte (R10h)Figure 7. 18 Vertical Scroll Height Area Register Low Byte (R11h)Himax ConfidentialThis information contained herein is the exclusive property of Himax and shall not be distributed, reproduced, or disclosedin whole or in part without prior written permission of Himax.-P.91-July, 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!