11.07.2015 Views

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FX06</strong> <strong>Field</strong> <strong>Controller</strong> Technical Specifications (Part 2 of 2)Relay OutputsDigital Outputs forSelected ModelsDielectric test voltage on open relay contact: 1,000 VAC RMSMaximum relay switching rate at nominal load: 6 operations/minModel Channel Type Remark/Application<strong>FX06</strong>P0x/P1x DO1 – DO6 SPST 3(1) A,250 VAC relayEach relay contact is independent withits own common terminal.<strong>FX06</strong>P2x/P3xDO1, DO20.5 A/24 VACtriacs3-point incremental actuators, thermalactuators, etcConnectionsDimensions(H x W x D)ComplianceDO3 – DO6 SPST 3(1) A,250 VAC relayOn the <strong>FX06</strong>P2x models, each relaycontact is independent with its owncommon terminal.On the <strong>FX06</strong>P3x model, DO4, DO5,and DO6 relays are physicallyinterlocked such that only one outputcan be closed at one time. Application:3-speed fan motors.The DO3 relay is independent.Molex® connectors. Mating connectors and cables provided with controller or available to order.See Order Codes.See Figures 7 and 8.Europe – 89/336/EEC, EMC Directive: EN 61000-6-3, EN 61000-6-2– 72/23/EEC, Low Voltage Directive: EN 60730Canada– UL Listed (PAZX7), CAN/CSA C22.2 No. 205, Signal Equipment– UL Recognized (XAPX8), CAN/CSA C22.2 No. 24, TemperatureIndicating and Regulating Equipment– Industry Canada, ICES-003United States – UL Listed (PAZX), UL 916, Energy Management Equipment– UL Recognized (XAPX2), UL 873, Temperature Indicating andRegulating Equipment– FCC compliant to CFR 47, Part 15, Subpart B, Class AThe performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond thesespecifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication ormisuse of its products.Controls Group Global Headquarters507 E. Michigan StreetP.O. Box 423Milwaukee, WI 53201Published in U.S.A. and Europe<strong>FX06</strong> <strong>Field</strong> <strong>Controller</strong> <strong>Product</strong> <strong>Bulletin</strong> 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!