11.07.2015 Views

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

Facility Explorer FX06 Field Controller Product Bulletin - klimagra

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ordering CodesTables 1 through 7 give ordering information for the <strong>FX06</strong> <strong>Controller</strong>s, <strong>FX06</strong> Accessories, Room Command Modulesand Configuration Software.Table 1: <strong>FX06</strong> <strong>Field</strong> <strong>Controller</strong> Ordering Information<strong>Product</strong> CodeNumberLP-<strong>FX06</strong>P00-000CLP-<strong>FX06</strong>P01-000CLP-<strong>FX06</strong>P02-000CLP-<strong>FX06</strong>P03-000CLP-<strong>FX06</strong>P10-000CLP-<strong>FX06</strong>P11-000CLP-<strong>FX06</strong>P12-000CLP-<strong>FX06</strong>P13-000CLP-<strong>FX06</strong>P20-000CLP-<strong>FX06</strong>P21-000CLP-<strong>FX06</strong>P22-000CLP-<strong>FX06</strong>P23-000CLP-<strong>FX06</strong>P30-000CLP-<strong>FX06</strong>P31-000CLP-<strong>FX06</strong>P32-000CLP-<strong>FX06</strong>P33-000CDescription<strong>FX06</strong> <strong>Controller</strong> with 4 Analog Inputs (AIs), 5 Binary Inputs (BIs): 2 Analog Outputs (AOs) (0-10 V),6 Binary Outputs (BOs) (Relays)<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (Relays), N2 Open Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (Relays), LONWORKS Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (Relays), RS232C Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (1 0-10 V, 1 PWM [Factory setting]), 6 BOs (Relays)<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (1 0-10 V, 1 PWM [Factory setting]), 6 BOs (Relays),N2 Open Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (1 0-10 V, 1 PWM [Factory setting]), 6 BOs (Relays),LONWORKS Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (1 0-10 V, 1 PWM [Factory setting]), 6 BOs (Relays),RS232C Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (4 Relays, 2 Triacs)<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (4 Relays, 2 Triacs), N2 Open Module,1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (4 Relays, 2 Triacs), LONWORKS Module,1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (4 Relays, 2 Triacs), RS232C Module,1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (3 Interlocked Relays, 1 Free Relay,2 Triacs)<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (3 Interlocked Relays, 1 Free Relay,2 Triacs), N2 Open Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (3 Interlocked Relays, 1 Free Relay,2 Triacs), LONWORKS Module, 1 cable set<strong>FX06</strong> <strong>Controller</strong> with 4 AIs, 5 BIs: 2 AOs (0-10 V), 6 BOs (3 Interlocked Relays, 1 Free Relay,2 Triacs) RS232C Module, 1 cable setTable 2: Communication Module Ordering Information<strong>Product</strong> CodeNumberLP-NET061-000CLP-NET062-000CLP-NET063-000CDescriptionN2 Open Communication ModuleLONWORKS Communication ModuleRS232C Communication Module6 <strong>FX06</strong> <strong>Field</strong> <strong>Controller</strong> <strong>Product</strong> <strong>Bulletin</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!