G: TroubleshootingThe Channel Strip (629921X1 / 629994X1)First, remove the scribble strip (three screws). Now remove the Solos and Cuts Panel (629922X1) that fits across thebottom of each bay of eight channels; remove the two countersunk screws, then carefully lift the panel clear onto a pieceof foam or bubble wrap. Disconnect the ribbon and put the panel to one side.Each channel strip is connected to the frame of the console by three screws – one at the top next to the meters, one atthe bottom (revealed when the Solo and Cuts Panel has been removed) and one at the rear of the console just above thechannel’s XLR connectors (you will have to look carefully to find this one). When the screws have been removed, screwthe module puller into the top hole. Using both the puller, and the finger hole next to the bottom screw, pull the channelstrip clear from its edge connectors.Appendices Page A-16<strong>AWS</strong> <strong>924</strong>-<strong>948</strong> Owner’s Manual