AutomationAUTOMATION SETUP OPTIONSThe SSL>MISC>SETUP contains various options for the mix system. Scroll to the option to be edited and select usingthe Left V-pot push switch. Once the option is active, the left V-pot will increment/decrement a numerical value as it is turnedor page through the various option states. Press the V-pot push switch a second time to complete the setup operation.Glide Frames Sets the ramp time in frames for Snap mode. The range is from 0 (no glide) to 255(10 second glide).Rollback Threshold framesLatched Match & PlayIn Mix ShowSets the number of consecutive descending frames that the system needs to see todetermine if a rollback has taken place. The range is 2-10 and the default is 2 frames.Increase as required if a rollback occurs on stopping the timecode master.Normally Match and Play are automatically deselected after a Cut switch isoperated. This option latches the Match or Play function until deselected manually.This determines what is displayed on the channels scribble strips when usingautomation. Choices are:• Automation Mode - shows Manual, Safe or Auto• Channel names in mix running - After pressing Execute willdisplay channel names• Channel names - will always display channel names<strong>AWS</strong> <strong>924</strong>-<strong>948</strong> Operator’s Manual Page 7-15