11.07.2015 Views

M035 Ethernet – RS485 data converter and Modbus RTU / TCP router

M035 Ethernet – RS485 data converter and Modbus RTU / TCP router

M035 Ethernet – RS485 data converter and Modbus RTU / TCP router

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>M035</strong><strong>Ethernet</strong> – <strong>RS485</strong> <strong>data</strong> <strong>converter</strong><strong>and</strong> <strong>Modbus</strong> <strong>RTU</strong> / <strong>TCP</strong> <strong>router</strong>Summary<strong>M035</strong> is a <strong>RS485</strong> to 10/100 Mbit <strong>Ethernet</strong> <strong>converter</strong>, also called „terminal server“,configurable as <strong>Modbus</strong> <strong>RTU</strong>/<strong>TCP</strong> <strong>router</strong>.Applicationsremote <strong>Modbus</strong> <strong>RTU</strong> / <strong>RS485</strong> devices to SCADA <strong>Modbus</strong> IP connection via<strong>Ethernet</strong> networkFunctionsThe <strong>M035</strong> module is able to connect a <strong>Modbus</strong> <strong>RTU</strong> <strong>RS485</strong> device to a PC with<strong>Modbus</strong> <strong>TCP</strong> master via an <strong>Ethernet</strong> network. Maximum <strong>RS485</strong> communication speedis 115 200 bps.The module parameters <strong>and</strong> functions are configured over a secured webcommunication (HTTP / HTTPS protocols). Default IP address is 192.168.1.37/24, oruse configuration utility which is available at www.rcware.eu, Download, Software, Digiutility. Power presence is indicated by a green LED close to the <strong>Ethernet</strong> connector. The<strong>Ethernet</strong> connector provides two LEDs: Link (yellow) <strong>and</strong> Network activity (green). Thenetwork switches automatically between 10 <strong>and</strong> 100 Mbit/s.The <strong>Modbus</strong> <strong>RTU</strong> slave at <strong>RS485</strong> device connects through 2-wire connector. It ispossible to terminate the <strong>RS485</strong> bus by setting the two jumpers below to ON.Technical <strong>data</strong>Supply voltage10 V ÷ 35 V DC, 14 V ÷ 24 V AC, any polarityConsumption1500 mVAWorking temperature of the device -40 ÷ 85°CCommunication<strong>Ethernet</strong>IP addressingProtocolsSecurityhigh speed <strong>RS485</strong>, 1200 ... 115 200 bit/s(TXD, RXD, RTS, CTS, DTR, DSR <strong>and</strong> DCD)automatic 10 or 100 Mbit/sfixed or DHCP assigned IP address<strong>TCP</strong>, UDP, DHCP, SNMP, SSL / TSL, <strong>Modbus</strong>,HTTP, SMTP, ICMP, IGMP, <strong>and</strong> ASRbased on SSL V3.0 / TSL V1.0 (DES 56 bit,domat <strong>M035</strong> 1


LEDs <strong>and</strong> switchesBUS ENDINITPWRRXTX<strong>Ethernet</strong>DS1<strong>RS485</strong> bus termination<strong>Ethernet</strong> chip init jumperpower OK, green LEDreceive <strong>data</strong> from <strong>RS485</strong>, green LEDtransmit <strong>data</strong> to <strong>RS485</strong>, red LEDLink, yellow LEDNetwork activity, green LED<strong>RS485</strong> Baud rate switch:domat <strong>M035</strong> 3


Dimensions14148,590458,53621,5535810Application exampleSerial Slave connection Serial Master connectionRelated productsUC100UC200UC300FC010FC020RC-VisionIPCT.1M020M025M030M031M040M050communicative heating controllercommunicative heating <strong>and</strong> cooling controllercommunicative floor heating controllercommunicative fan coil controllercommunicative fan coil controller for analogue room unitSCADA softwareprocess station with touch screenRS232 / <strong>Ethernet</strong> <strong>converter</strong>, terminal serverRS232 / <strong>Ethernet</strong> <strong>converter</strong>, <strong>Modbus</strong> <strong>router</strong><strong>RS485</strong>/422 / <strong>Ethernet</strong> <strong>converter</strong>, terminal server<strong>RS485</strong> / <strong>Ethernet</strong> <strong>converter</strong>, terminal serverRS232 / WiFi <strong>converter</strong>, terminal server<strong>RS485</strong> / WiFi <strong>converter</strong>, terminal server09/2011 Subject to technical changes.4 domat <strong>M035</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!