11.07.2015 Views

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ®Basic <strong>Rack</strong> PDU: Robust <strong>PDUs</strong> withhelpful equipment featuresKnürr's Basic <strong>Rack</strong> <strong>PDUs</strong> are thesolution for every data center lookingfor robust, economical and flexiblerack concepts.For power distribution the KnürrDI-STRIP® product family meetsthe requirements of numerous ITapplications and other areas.Specially configured for the growingnumber of electronic componentsin network switching racks of serverracks. Available with differentaccessories, such as circuit breakers,overvoltage (surge) protection,mains filter, master-slave function,emergency off button, fault currentcircuit breaker, local and remotepower measurement, for example.■ Highest possible safety, securityand availability with:- Closed sheet steel extrusion, whichmeans high stability and torsionalstrength.- Extensive certification in acc. withinternational standard.- Double spring contacts for shockhazard-proof and low contactresistance.- Unbalanced load monitoring with3-phase feed prevents feed cableoverload (only DI-STRIP versionsM and RM).- Optimum load monitoring withservers' installation (only DI-STRIPversions M and RM).- Individual outputs backup withDI-STRIP Blade<strong>Power</strong> and Pizza<strong>Power</strong>.■ Maximum flexibility with:- Configurations and options withinternational compatibility- 2.5 m or 4 m power cable for morespatial flexibility.- Rotating display in 90° steps (onlyDI-STRIP versions M and RM).- Tool-less installation, which meansquick and easy extension in the rack(only DI-STRIP High<strong>Power</strong>).■ Extremely low operating costswith:- Quick and easy installation on therack requires minimum space andshorter installation time.- Automatic background lightreduction extends the display'sservice life and reduces the rackPDU power loss (only DI-STRIPmodels M and RM).- Especially flat housing extrusion,providing full accessibility tothe 19” level with 600 mm wideserver racks.All DI-STRIP M / RM with display rotationfor better reading.2.19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!