Power Quality Monitoring
Power Quality Monitoring
Power Quality Monitoring
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
▼Chapter 2Scope of operation and technical dataGeneral technical dataOperating voltage L-N, ACOvervoltage categoryQuadrants 4Refer to order details600V CAT IIIScanning rate 6 channel Per channel 6.4 / 7.68 kHzWeightDimensionsMounting1kgW=144mm x H=144mm x D=66.5mmFront panel installationWorking temperature -10…55 °CConnectable conductors (U/I)Single wire, multi-wire, fine-wire,0.08 - 2.5mm 2pin cable lugs, ferrule1.5mm 2Protection class (front/reverse) According to EN60529 IP 50/20Measurement rangeVoltage L-N, AC (without voltage transformer)Voltage L-L, AC (without voltage transformer)Current (transformer: x/1 and x/5 A)Frequency of mainsGrid typesMeasurement in single and multi-phase networks50…500VAC80…870VAC0.005...6A45...65HzTN, TT, (IT)1ph, 2ph, 3ph and up to 3x1phMeasurement valuesMeasurementparameterDisplay rangeMeasurement rangeat scaling factor 1L1 L2 L3SumLowestvalueAverage Maximumvalue * 1 valueDate/timeMeasurementaccuracyCurrent .. /5A 0.000 .. 9999 A 0.005 .. 6 A +-0.2 % rngCurrent .. /1A 0.000 .. 9999 A 0.005 .. 1 A +-0.2 % rngCurrent, neutral wire 0.000 .. 9999 A 0.060 .. 15 A +-0.6 % rngVoltage L-N 0.0 .. 999.9 MV 50 .. 500 V +-0.2 % rngVoltage L-L 0.0 .. 999.9 MV 80 .. 870 V +-0.2 % rngFrequency (U) 45.00 .. 65.00 Hz 45.00 .. 65.00 Hz +-0.2 % rdgEffective power +/- 0.00 W .. 9999 MW 0.05 W .. 2.5 kW +-0.5 % rngApparent power 0.00 VA .. 9999 MVA 0.05 VA .. 2.5 kVA +-0.5 % rngReactive power 0.00 kvar .. 999 Mvar 0.05 var .. 2.5 kvar kap. ind. +-0.5 % rng<strong>Power</strong> factor 0.00 kap. .. 1.00 .. 0.00 ind. 0.00 kap. .. 1.00 .. 0.00 ind. kap. ind. +-0.5 % rngEffective energy + 0.0 Wh .. 9999 GWh 0.05 Wh .. 9999 GWh *2 t1/t2 *3Effective energy - -0.0 Wh .. -9999 GWh -0.05 Wh .. -9999 GWh *2Reactive energy +/- 0.0 .. 9999 Gvarh 0.05vars .. 9999 Mvarh *2 t1/t2 *3Rng: from measurement range, rdg: from measurement value, t1: start time, t2: runtime, + purchase, - supply, *1 - integration over time: 5, 10, 15, 30 seconds, 1, 5, 10, 15, 30, 60 minutes,*2 memory period 60 minutes, *3 accuracy class according to EN61036:1996, VDE0418 part 7:May 1997, IEC1036:1996, with current transformer ../5A : class 1, with current transformer ../1A : class 2<strong>Power</strong> qualityHarmonics, 1 st to 20 th harmonics,even/uneven Current, voltage L1, L2, L3 Accuracy: ± 0.5% rngDistortion factor THD-U in % L1, L2, L3 Accuracy: ± 0.5% rngDistortion factor THD-I in % L1, L2, L3 Accuracy: ± 0.5% rngRecorder for limit value eventsYesMeasurement accuracyReactive energy kvarh Class 1Effective energy kWh Class 157