11.07.2015 Views

Power Quality Monitoring

Power Quality Monitoring

Power Quality Monitoring

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

▼UMG 96SMeasurement rangeVoltage L-N, AC (without voltage transformer)Voltage L-L, AC (without voltage transformer)Current ( transformer: x/1 and x/5A)Frequency of mainsGrid typesMeasurement in single phase/multiphase networksRefer to order detailsRefer to order details0.01...6A45...65HzTN,TT1ph, 2ph, 3ph and up to 3 x 1phMeasurement valuesMeasurementparameterDisplay rangeMeasurement rangeat scaling factor 1L1 L2 L3SumLowestvalueAverage Maximumvalue * 1 valueMeasurementaccuracyCurrent 0.01 .. 60.0 kA 0.01 .. 6 A +-0.5 % rngCurrent calculated in N 0.01 .. 180.0 kA 0.01 .. 18 A +-1.5 % rngVoltage L-N 0.0 .. 34 kV 50 .. 300 V +-0.5 % rngVoltage L-L 0.0 .. 60 kV 87 .. 520 V +-1.0 % rngFrequency (U) 45.00 .. 65.00 Hz 45.00 .. 65.00 Hz +-0.1 % rdgEffective power per phase 0.1 W .. 99.9 MW 0.1 W .. 1.8 kW +-1.0 % rngApparent power per phase 0.1 VA .. 99.9 MVA 0.1 VA .. 1.8 kVA +-1.0 % rngReactive power per phase 0.1 var .. 99.9 Mvar 0.1 var .. 1.8 kvar ind. +-1.0 % rngEffective power, sum 1.0 W .. 99.9 MW 1.0 W .. 5.4 kW +-1.0 % rngApparent power, sum 1.0 VA .. 99.9 MVA 1.0 VA .. 5.4 kVA +-1.0 % rngReactive power, sum 1.0 var .. 99.9 Mvar 1.0 var .. 5.4 kvar ind. +-1.0 % rngCos phi 0.00 kap. .. 1.00 .. 0.00 ind. 0.00 kap. .. 1.00 .. 0.00 ind. +-1.0 degreeEffective energy, consumed 0 .. 999.999.999 kWh Class 1(5A) 2 (1A)Reactive energy, inductive 0 .. 999.999.999 kvarh Class 1(5A) 2 (1A)Operating hour meter 0 .. 999.999.999 h +-2 min per dayrng: of measurement range, rdg: of measurement value*1 integration over time: 5, 10, 30, 60, 300, 480, 600 and 900 seconds<strong>Power</strong> qualityHarmonics, 1 st to 15 th harmonics,uneven Current, voltage L1, L2, L3 Accuracy: ± 2% rngDistortion factor THD-U in % L1, L2, L3 Accuracy: ± 2% rngDistortion factor THD-I in % L1, L2, L3 Accuracy: ± 2% rngRecorder for threshold eventsYes, for units with memoryMeasurement accuracyAccuracy V, A± 0.5 % rngReactive energy (karh) Class 1 (5A) 2 (1A)Effective energy (kWh) Class 1 (5A) 2 (1A)PeripheryDigital inputs As a status input or pulse input 2, refer to order detailsDigital outputs As a switch output or pulse output 2Analogue outputs 4...20mA 2, refer to order detailsPassword protectionYesSoftware GridVis Refer to chapter 5 YesCommunicationInterfacesRS 232 9.6, 19.2, 38.4 kbps; RJ11 Refer to order detailsRS 485 9.6, 19.2, 38.4 kbps; terminal strip Refer to order detailsM-bus Plug, sub D 9-pole Refer to order detailsProtocolsModbus RTU 9.6, 19.2, 38.4 kbps YesProfibus DP V0 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500 kbps Refer to order detailsM-bus 0.3, 2.4, 9.6 kbps Refer to order details50

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!