11.07.2015 Views

Power Quality Monitoring

Power Quality Monitoring

Power Quality Monitoring

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

▼Chapter 2Product variants and technical dataOverview of product variants (transfer rates: Modbus 9.6, 19.2, 38.4kBit/s; Profibus 9.6, 19.2, 93.75, 187.5, 500 kBit/s and 1.5 MBit/s)2 digital outputsSelectableactivation* 12 digital inputs2 analogue outputs 4-20mARS485 (Modbus RTU)Selectableactivation* 2RS232 (Modbus RTU)Clock / memoryProfibus interface (DP V0)* 4M-bus* 4Auxiliary voltage: 24V DC300V standard versionMeasurement range: L-N 50 - 300V; AC* 3Measurement range: L-L 87 .. 520V; AC150V special versionMeasurement range: L-N 25 - 150V; ACMeasurement range: L-L 40 .. 250V; AC L-N: 85 .. 300V, AC 52.13.001 L-N: 85 .. 300V, AC 52.13.005 L-N: 85 .. 300V, AC 52.13.009 L-N: 85 .. 300V, AC 52.13.013 L-N: 85 .. 300V, AC 52.13.017 L-N: 85 .. 300V, AC 52.13.021 L-N: 140 .. 300V, AC 52.13.025 L-N: 140 .. 300V, AC 52.13.040 18 .. 70V DC, 18 .. 33V, ACauxiliary voltage52.13.029 L-L: 85 .. 260V, AC 52.13.002 L-L: 85 .. 260V, AC 52.13.006 L-L: 85 .. 260V, AC 52.13.010 L-L: 85 .. 260V, AC 52.13.014 L-L: 85 .. 260V, AC 52.13.018 L-L: 85 .. 260V, AC 52.13.022 L-L: 85 .. 260V, AC 52.13.026 18 .. 70V DC, 18 .. 33V, ACauxiliary voltage52.13.031 = Included = Not included*1 - combination options for inputs and outputs: a) 2 digital outputs, b) 2 digital inputs, c) 2 analogue outputs, d) 1 digital output and 1 analogue output, e) 1 digital output and 1 digital input.*2 - the RS232 interface cannot be simultaneously operated with the RS485 interface.*3 - auxiliary range for units with Profibus: 140V...300V AC. Also available: special version with operating voltage: L-N: 25...140V, L-L: 85...260VAC*4 - these units are only suitable for applications in industrial areas.General technical dataOperating voltage L-N, ACRefer to order detailsOvervoltage category300V CAT III, 600V CAT IIQuadrants 4Scanning rate 6 channel Per channel 2.5 / 3 kHzWeight250gDimensionsW= 96mm x H= 96mm x D= 49mmMountingFront panel installationWorking temperature -10…55 °CConnectable conductors (U/I)Single wire, multi-wire, fine-wire,pin cable lugs, ferruleOperating voltage0.08 - 2.5mm 21.5mm 2Protection class (front/reverse) According to EN60529 IP 50/20Item number49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!