Power Quality Monitoring
Power Quality Monitoring Power Quality Monitoring
▼Chapter 7Logistics informationCardboard packaging sizesShipping packagingTypeDimensionsWxHxD in mmPackaging weight in gBox Plastic SumNet weight of unit inkg (incl. Operatingmanual etc)Gross weight in kg Device type Number of unitsin packageUnit carton 1 180x85x145 98,05 2,45 105,00 0.275 0.38 UMG 96L / 96 1Unit carton 1 180x85x145 98,05 2,45 105,00 0.455 0.56 UMG 96S 1Unit carton 1 180x85x145 98,05 2,45 105,00 0.195 0.30 UMG 103 1Unit carton 2 180x140x170 165,30 4,70 170,00 1.190 1.36 UMG 503-505 1Unit carton 2 180x140x170 165,00 4,70 170,00 1.150 1.32 UMG 507 1Unit carton 2 180x140x170 165,30 4,70 170,00 0.610 0.78 UMG 104/604/605 1Unit carton 2 180x140x170 165,30 4,70 170,00 1.010 1.18 Prophi 1Unit carton 2 *1 180x140x170 165,30 4,70 170,00 1.500 1.67 UMG 508/511 1Unit carton 3 *2 150x210x240 285,50 8,50 294,00 1.500 1.79 UMG 508/511 1▼Cardboard packaging sizesShipping packaging Total weight in kg with the respective device type *3TypeMastercarton 1Mastercarton 2Mastercarton 3Mastercarton 4Mastercarton 5Mastercarton 6Mastercarton 7Master carton8 on palletMaster carton9 on palletMaster carton10 on palletDimensionsLxWxHin mmPackagingweightin kgUnit carton1 or 2,quantity per layerNumberof layersMax number ofunit carton 1 or 21 2 1 2315x225x170 0.21 1 - 1 3 - 1.4 1.9 1.1 - - - - -400x300x250 0.39 10 4 1 10 4 4,2 6.0 3.4 5.8 5.7 3.5 5.9 6.9340x240x280 0.28 7 4 1 7 4 2.9 4.2 2.4 5.7 5.6 3.4 5.0 6.8395x340x390 0.89 8 4 2 16 8 7.0 9.9 5.7 11.8 11.5 7.1 10.3 13.9440x395x390 0.86 13 6 2 26 12 10.8 15.5 8.7 17.3 16.8 10.3 15.1 20.4700x400x400 1.42 20 10 2 40 20 16.6 23.8 13.4 28.6 27.8 17.0 25.1 33.8800x400x400 1.52 23 10 2 46 20 19.0 27.3 15.3 28.7 27.9 17.1 25.1 33.9800x600x400 7.25 36 15 2 72 30 34.6 47.6 28.9 48.1 46.9 30.7 42.7 55.91180x780x675 17.50 64 32 3 192 96 90.5 125.0 75.5 148.0 143.5 92.5 131.0 173.01180x780x905 18.60 64 32 4 256 128 115.9 162.0 95.4 192.7 187.6 118.4 169.6 226.0*1 – This packaging is not suitable for individual despatch of UMG 508 and UMG 511. *2 – This packaging is only used for individual despatchesof UMG 508 and UMG 511. *3 – The weight of item number 52.13.025 has been applied to the UMG 96S. *4 – The details of the total weight ofthe respective unit type is based on a single variety only. Unit carton 1 and 2 is also used inside the master cartons. Packaging 3 is exclusively usedfor single shipments of UMG 5xx and UMG 6xx outside of Europe due to the customs documents.UMG96orUMG96LUMG96S *3UMG103UMG503orUMG505UMG507UMG104604605Prophi ®UMG508511213
Project description – industryThe problem:Transparency regarding energy costs and power quality is continuously becoming moreand more important in industrial companies. Energy consumption must be allocated tothe production stages and the final products in order to simplify pricing policies.Due to the use of non linear consumers such as frequency converters, problems oftenarise with electronic equipment and controls. Reactive power compensation systems areusually subject to particularly high loads and, therefore, require skilled engineering.Expensive peak loads can be avoided with intelligent peak demand management.The task:A supplier to the automobile industry decided to relocate its complete productionfacilities and construct the buildings in a “green belt” area. The company wanted tocollect consumption data for all welding robots together with compressed air consumptionand heating supplies and provide the data to the controlling department.The power quality from the four main feeds needed to be monitored and the fourrespective PFC systems needed to be integrated in the energy management system.Peak demand management had to be anticipated in order to reduce high electricity costsdue to high loadpeaks, shutdowns of compressors and air conditioning units etc. for ashort period will be the solution. Intranet was available as a communication medium.The solution:The UMG 96 of Janitza electronics ® , which passes on the effective pulses to theProData ® data logger, was used as a meter for electrical en er gy consumption. Otherpulse meters for compressed air and heating were also connected to the ProData ®using the pulse outputs.Four UMG 508´s were deployed in the four main feeders in order to determine thepower quality. Four Prophi ® 12TS reactive power controllers were also visualisedusing the RS485 in GridVis software. Distinctive feature:The four PFC systems work as a so-called mixed operation, which means that the baseload is compensated using the conventional contactors. The rapidly changing loadproportions, as caused by welding systems, are switched using thyristor modules.This means that dynamic PFC can be created for almost the same price as the conventionalcompensation system. A globally unique feature of the Prophi ®controller. The UMG 511 works as peak demand management and as a master fordownstream WAGO modules as well as a gateway for the RS485 bus cable toEthernet/TCP/IP.214
- Page 164 and 165: Chapter 6AccessoriesRemote maintena
- Page 166 and 167: ▼Chapter 6Moulded case current tr
- Page 168 and 169: ▼Chapter 6Moulded case current tr
- Page 170 and 171: ▼Chapter 6Cable split core CTs▼
- Page 172 and 173: ▼Chapter 6Split core current tran
- Page 174 and 175: ▼Chapter 6Current transformersDIN
- Page 176 and 177: ▼Chapter 6Current transformer acc
- Page 178 and 179: ▼Chapter 6Mechanical accessoriesM
- Page 180 and 181: ▼Chapter 6Mechanical accessoriesA
- Page 182 and 183: ▼Chapter 6Field bus componentsDe-
- Page 184 and 185: ▼Chapter 6Field bus componentsDe-
- Page 186 and 187: ▼Chapter 6Field bus componentsAcc
- Page 188 and 189: ▼Chapter 6Field bus componentsJaT
- Page 190 and 191: ▼Chapter 6Field bus componentsM-B
- Page 192 and 193: ▼Chapter 6Field bus componentsPea
- Page 194 and 195: ▼Chapter 6NTP serverInstallationT
- Page 196 and 197: ▼Chapter 6ServerWe leave you also
- Page 198 and 199: ▼▼Chapter 6ServerApplicationAny
- Page 200 and 201: ▼Chapter 6Touch panelsGeneralJPC1
- Page 202 and 203: ▼Chapter 6Touch panelsApplication
- Page 204 and 205: ▼Chapter 6Touch panels (HMI)Touch
- Page 206 and 207: ▼Chapter 7AppendixApplication at
- Page 208 and 209: ▼Chapter 7Cable diameters & fuse
- Page 210 and 211: ▼Chapter 7Fixed compensationSelec
- Page 212 and 213: ▼Chapter 7Communication▼Connect
- Page 216 and 217: ▼Chapter 7Application example▼
- Page 219: Project description - BankThe probl
- Page 222 and 223: 221▼Janitza electronics ®
- Page 224 and 225: 223▼Janitza electronics ®
- Page 226 and 227: 225▼Janitza electronics ®
- Page 228: Janitza electronics GmbHVor dem Pol
▼Chapter 7Logistics informationCardboard packaging sizesShipping packagingTypeDimensionsWxHxD in mmPackaging weight in gBox Plastic SumNet weight of unit inkg (incl. Operatingmanual etc)Gross weight in kg Device type Number of unitsin packageUnit carton 1 180x85x145 98,05 2,45 105,00 0.275 0.38 UMG 96L / 96 1Unit carton 1 180x85x145 98,05 2,45 105,00 0.455 0.56 UMG 96S 1Unit carton 1 180x85x145 98,05 2,45 105,00 0.195 0.30 UMG 103 1Unit carton 2 180x140x170 165,30 4,70 170,00 1.190 1.36 UMG 503-505 1Unit carton 2 180x140x170 165,00 4,70 170,00 1.150 1.32 UMG 507 1Unit carton 2 180x140x170 165,30 4,70 170,00 0.610 0.78 UMG 104/604/605 1Unit carton 2 180x140x170 165,30 4,70 170,00 1.010 1.18 Prophi 1Unit carton 2 *1 180x140x170 165,30 4,70 170,00 1.500 1.67 UMG 508/511 1Unit carton 3 *2 150x210x240 285,50 8,50 294,00 1.500 1.79 UMG 508/511 1▼Cardboard packaging sizesShipping packaging Total weight in kg with the respective device type *3TypeMastercarton 1Mastercarton 2Mastercarton 3Mastercarton 4Mastercarton 5Mastercarton 6Mastercarton 7Master carton8 on palletMaster carton9 on palletMaster carton10 on palletDimensionsLxWxHin mmPackagingweightin kgUnit carton1 or 2,quantity per layerNumberof layersMax number ofunit carton 1 or 21 2 1 2315x225x170 0.21 1 - 1 3 - 1.4 1.9 1.1 - - - - -400x300x250 0.39 10 4 1 10 4 4,2 6.0 3.4 5.8 5.7 3.5 5.9 6.9340x240x280 0.28 7 4 1 7 4 2.9 4.2 2.4 5.7 5.6 3.4 5.0 6.8395x340x390 0.89 8 4 2 16 8 7.0 9.9 5.7 11.8 11.5 7.1 10.3 13.9440x395x390 0.86 13 6 2 26 12 10.8 15.5 8.7 17.3 16.8 10.3 15.1 20.4700x400x400 1.42 20 10 2 40 20 16.6 23.8 13.4 28.6 27.8 17.0 25.1 33.8800x400x400 1.52 23 10 2 46 20 19.0 27.3 15.3 28.7 27.9 17.1 25.1 33.9800x600x400 7.25 36 15 2 72 30 34.6 47.6 28.9 48.1 46.9 30.7 42.7 55.91180x780x675 17.50 64 32 3 192 96 90.5 125.0 75.5 148.0 143.5 92.5 131.0 173.01180x780x905 18.60 64 32 4 256 128 115.9 162.0 95.4 192.7 187.6 118.4 169.6 226.0*1 – This packaging is not suitable for individual despatch of UMG 508 and UMG 511. *2 – This packaging is only used for individual despatchesof UMG 508 and UMG 511. *3 – The weight of item number 52.13.025 has been applied to the UMG 96S. *4 – The details of the total weight ofthe respective unit type is based on a single variety only. Unit carton 1 and 2 is also used inside the master cartons. Packaging 3 is exclusively usedfor single shipments of UMG 5xx and UMG 6xx outside of Europe due to the customs documents.UMG96orUMG96LUMG96S *3UMG103UMG503orUMG505UMG507UMG104604605Prophi ®UMG508511213