▼Chapter 7Cable diameters & fuse sizingfor power factor correctionWe provide general non-binding information about common practices in this table. Connection diameters and the fuse rating aredependent upon the nominal power of the PFC system, the national regulations, the cable material used and the environmentalconditions. The recommendation for fuse amperage is only for short-circuit protection, HRC fuses are not suitable to protectPFC capacitors against overloading. The system manufacturer or the planning office is responsible for calculating and selectingcable diameters and fuses for each individual case.PFC cable diameters, fuses (for 400V/50Hz) networksPower inkvarNominal current inACable diameterNYY-J mm 2HRC fuseA5 7 4 x 2,5 167,5 10 4 x 4 2010 14 4 x 4 2512,5 18 4 x 6 3515 22 4 x 6 3517,5 25 4 x 10 5020 29 4 x 10 5025 36 4 x 16 6330 43 4 x 16 8037,5 54 4 x 25 10050 72 3 x 35/16 12555 - 65 79 - 94 3 x 35/16 16070 - 85 101 - 123 3 x 70/35 20086 - 100 124 - 145 3 x 95/50 250101 - 125 146 - 181 3 x 120/70 250126 - 160 182 - 231 2’’ 3 x 70/35 315161 - 180 233 - 260 2’’ 3 x 95/50 400181 - 200 261 - 289 2’’ 3 x 120/70 400201 - 250 290 - 361 2’’ 3 x 150/70 500251 - 300 362 - 434 2’’ 3 x 185/95 630Connection diameters are only valid for the given capacitor power levels▼PFC systems with a power level of more than 300 kvar have 2 separate bus bar systems and require 2 separate feeders. The tableapplies to conventional or de-tuned PFC systems. The actual valid regulations (e.g. DIN VDE 0298) must always be observed.Important note: the bus bar separation must be allocated before extending any existing systems.207
Cos-phiCalculating the kvar system powerThis selection table was created for calculating the necessary reactive power. On the basis of the actual power factor and the target powerfactor a multiplier can be determined from this table, which has to be multiplied with the effective power to be compensated. The resultis the necessary reactive power for the PFC system. This table can also be found as an MS Excel document for online calculation onour homepage in the submenu “tools”.Cos-Phi selection tableACTUALtanϕcosϕTarget power factorcosϕEffective power P = 100 kWACTUAL cosϕ = 0.65TARGET cosϕ = 0.95Factor F from table = 0.84Compensation power QC = P x (tanϕ1 - tanϕ2)P * F100 x 0.8484 kvar0.80 0.82 0.85 0.88 0.90 0.92 0.94 0.95 0.96 0.98 1.001.33 0.60 0.58 0.64 0.71 0.79 0.85 0.91 0.97 1.00 1.04 1.13 1.331.30 0.61 0.55 0.60 0.68 0.76 0.81 0.87 0.94 0.97 1.01 1.10 1.301.27 0.62 0.52 0.57 0.65 0.73 0.78 0.84 0.90 0.94 0.97 1.06 1.271.23 0.63 0.48 0.53 0.61 0.69 0.75 0.81 0.87 0.90 0.94 1.03 1.231.20 0.64 0.45 0.50 0.58 0.66 0.72 0.77 0.84 0.87 0.91 1.00 1.201.17 0.65 0.42 0.47 0.55 0.63 0.68 0.74 0.81 0.84 0.88 0.97 1.171.14 0.66 0.39 0.44 0.52 0.60 0.65 0.71 0.78 0.81 0.85 0.94 1.141.11 0.67 0.36 0.41 0.49 0.57 0.62 0.68 0.75 0.78 0.82 0.90 1.111.08 0.68 0.33 0.38 0.46 0.54 0.59 0.65 0.72 0.75 0.79 0.88 1.081.05 0.69 0.30 0.35 0.43 0.51 0.56 0.62 0.69 0.72 0.76 0.85 1.051.02 0.70 0.27 0.32 0.40 0.48 0.54 0.59 0.66 0.69 0.73 0.82 1.020.99 0.71 0.24 0.29 0.37 0.45 0.51 0.57 0.63 0.66 0.70 0.79 0.990.96 0.72 0.21 0.27 0.34 0.42 0.48 0.54 0.60 0.64 0.67 0.76 0.960.94 0.73 0.19 0.24 0.32 0.40 0.45 0.51 0.57 0.51 0.64 0.73 0.940.91 0.74 0.16 0.21 0.29 0.37 0.42 0.48 0.55 0.58 0.62 0.71 0.910.88 0.75 0.13 0.18 0.26 0.34 0.40 0.46 0.52 0.55 0.59 0.68 0.880.86 0.76 0.11 0.16 0.24 0.32 0.37 0.43 0.49 0.53 0.56 0.65 0.860.83 0.77 0.08 0.13 0.21 0.29 0.34 0.40 0.47 0.50 0.54 0.63 0.830.80 0.78 0.05 0.10 0.18 0.26 0.32 0.38 0.44 0.47 0.51 0.60 0.800.78 0.79 0.03 0.08 0.16 0.24 0.29 0.35 0.41 0.45 0.48 0.57 0.780.75 0.80 0.05 0.13 0.21 0.27 0.32 0.39 0.42 0.46 0.55 0.750.72 0.81 0.03 0.10 0.18 0.24 0.30 0.36 0.40 0.43 0.52 0.720.70 0.82 0.08 0.16 0.21 0.27 0.34 0.37 0.41 0.49 0.700.67 0.83 0.05 0.13 0.19 0.25 0.31 0.34 0.38 0.47 0.670.65 0.84 0.03 0.11 0.16 0.22 0.28 0.32 0.35 0.44 0.650.62 0.85 0.08 0.14 0.19 0.26 0.29 0.33 0.42 0.620.59 0.86 0.05 0.11 0.17 0.23 0.26 0.30 0.39 0.590.57 0.87 0.03 0.08 0.14 0.20 0.24 0.28 0.36 0.570.54 0.88 0.06 0.11 0.18 0.21 0.25 0.34 0.540.51 0.89 0.03 0.09 0.15 0.18 0.22 0.31 0.510.48 0.90 0.06 0.12 0.16 0.19 0.28 0.480.46 0.91 0.03 0.09 0.13 0.16 0.25 0.460.43 0.92 0.06 0.10 0.13 0.22 0.430.40 0.93 0.03 0.07 0.10 0.19 0.400.36 0.94 0.03 0.07 0.16 0.360.33 0.95 0.04 0.13 0.330.29 0.96 0.09 0.290.25 0.97 0.05 0.25Factor F208
- Page 157: MS Excel analysis toolsSoftwareCust
- Page 160 and 161: ▼Chapter 5SoftwareMS Excel VBAVBA
- Page 162 and 163: ▼▼Chapter 6AccessoriesCurrent t
- Page 164 and 165: Chapter 6AccessoriesRemote maintena
- Page 166 and 167: ▼Chapter 6Moulded case current tr
- Page 168 and 169: ▼Chapter 6Moulded case current tr
- Page 170 and 171: ▼Chapter 6Cable split core CTs▼
- Page 172 and 173: ▼Chapter 6Split core current tran
- Page 174 and 175: ▼Chapter 6Current transformersDIN
- Page 176 and 177: ▼Chapter 6Current transformer acc
- Page 178 and 179: ▼Chapter 6Mechanical accessoriesM
- Page 180 and 181: ▼Chapter 6Mechanical accessoriesA
- Page 182 and 183: ▼Chapter 6Field bus componentsDe-
- Page 184 and 185: ▼Chapter 6Field bus componentsDe-
- Page 186 and 187: ▼Chapter 6Field bus componentsAcc
- Page 188 and 189: ▼Chapter 6Field bus componentsJaT
- Page 190 and 191: ▼Chapter 6Field bus componentsM-B
- Page 192 and 193: ▼Chapter 6Field bus componentsPea
- Page 194 and 195: ▼Chapter 6NTP serverInstallationT
- Page 196 and 197: ▼Chapter 6ServerWe leave you also
- Page 198 and 199: ▼▼Chapter 6ServerApplicationAny
- Page 200 and 201: ▼Chapter 6Touch panelsGeneralJPC1
- Page 202 and 203: ▼Chapter 6Touch panelsApplication
- Page 204 and 205: ▼Chapter 6Touch panels (HMI)Touch
- Page 206 and 207: ▼Chapter 7AppendixApplication at
- Page 210 and 211: ▼Chapter 7Fixed compensationSelec
- Page 212 and 213: ▼Chapter 7Communication▼Connect
- Page 214 and 215: ▼Chapter 7Logistics informationCa
- Page 216 and 217: ▼Chapter 7Application example▼
- Page 219: Project description - BankThe probl
- Page 222 and 223: 221▼Janitza electronics ®
- Page 224 and 225: 223▼Janitza electronics ®
- Page 226 and 227: 225▼Janitza electronics ®
- Page 228: Janitza electronics GmbHVor dem Pol
Cos-phiCalculating the kvar system powerThis selection table was created for calculating the necessary reactive power. On the basis of the actual power factor and the target powerfactor a multiplier can be determined from this table, which has to be multiplied with the effective power to be compensated. The resultis the necessary reactive power for the PFC system. This table can also be found as an MS Excel document for online calculation onour homepage in the submenu “tools”.Cos-Phi selection tableACTUALtanϕcosϕTarget power factorcosϕEffective power P = 100 kWACTUAL cosϕ = 0.65TARGET cosϕ = 0.95Factor F from table = 0.84Compensation power QC = P x (tanϕ1 - tanϕ2)P * F100 x 0.8484 kvar0.80 0.82 0.85 0.88 0.90 0.92 0.94 0.95 0.96 0.98 1.001.33 0.60 0.58 0.64 0.71 0.79 0.85 0.91 0.97 1.00 1.04 1.13 1.331.30 0.61 0.55 0.60 0.68 0.76 0.81 0.87 0.94 0.97 1.01 1.10 1.301.27 0.62 0.52 0.57 0.65 0.73 0.78 0.84 0.90 0.94 0.97 1.06 1.271.23 0.63 0.48 0.53 0.61 0.69 0.75 0.81 0.87 0.90 0.94 1.03 1.231.20 0.64 0.45 0.50 0.58 0.66 0.72 0.77 0.84 0.87 0.91 1.00 1.201.17 0.65 0.42 0.47 0.55 0.63 0.68 0.74 0.81 0.84 0.88 0.97 1.171.14 0.66 0.39 0.44 0.52 0.60 0.65 0.71 0.78 0.81 0.85 0.94 1.141.11 0.67 0.36 0.41 0.49 0.57 0.62 0.68 0.75 0.78 0.82 0.90 1.111.08 0.68 0.33 0.38 0.46 0.54 0.59 0.65 0.72 0.75 0.79 0.88 1.081.05 0.69 0.30 0.35 0.43 0.51 0.56 0.62 0.69 0.72 0.76 0.85 1.051.02 0.70 0.27 0.32 0.40 0.48 0.54 0.59 0.66 0.69 0.73 0.82 1.020.99 0.71 0.24 0.29 0.37 0.45 0.51 0.57 0.63 0.66 0.70 0.79 0.990.96 0.72 0.21 0.27 0.34 0.42 0.48 0.54 0.60 0.64 0.67 0.76 0.960.94 0.73 0.19 0.24 0.32 0.40 0.45 0.51 0.57 0.51 0.64 0.73 0.940.91 0.74 0.16 0.21 0.29 0.37 0.42 0.48 0.55 0.58 0.62 0.71 0.910.88 0.75 0.13 0.18 0.26 0.34 0.40 0.46 0.52 0.55 0.59 0.68 0.880.86 0.76 0.11 0.16 0.24 0.32 0.37 0.43 0.49 0.53 0.56 0.65 0.860.83 0.77 0.08 0.13 0.21 0.29 0.34 0.40 0.47 0.50 0.54 0.63 0.830.80 0.78 0.05 0.10 0.18 0.26 0.32 0.38 0.44 0.47 0.51 0.60 0.800.78 0.79 0.03 0.08 0.16 0.24 0.29 0.35 0.41 0.45 0.48 0.57 0.780.75 0.80 0.05 0.13 0.21 0.27 0.32 0.39 0.42 0.46 0.55 0.750.72 0.81 0.03 0.10 0.18 0.24 0.30 0.36 0.40 0.43 0.52 0.720.70 0.82 0.08 0.16 0.21 0.27 0.34 0.37 0.41 0.49 0.700.67 0.83 0.05 0.13 0.19 0.25 0.31 0.34 0.38 0.47 0.670.65 0.84 0.03 0.11 0.16 0.22 0.28 0.32 0.35 0.44 0.650.62 0.85 0.08 0.14 0.19 0.26 0.29 0.33 0.42 0.620.59 0.86 0.05 0.11 0.17 0.23 0.26 0.30 0.39 0.590.57 0.87 0.03 0.08 0.14 0.20 0.24 0.28 0.36 0.570.54 0.88 0.06 0.11 0.18 0.21 0.25 0.34 0.540.51 0.89 0.03 0.09 0.15 0.18 0.22 0.31 0.510.48 0.90 0.06 0.12 0.16 0.19 0.28 0.480.46 0.91 0.03 0.09 0.13 0.16 0.25 0.460.43 0.92 0.06 0.10 0.13 0.22 0.430.40 0.93 0.03 0.07 0.10 0.19 0.400.36 0.94 0.03 0.07 0.16 0.360.33 0.95 0.04 0.13 0.330.29 0.96 0.09 0.290.25 0.97 0.05 0.25Factor F208