▼▼Chapter 2UMG 103Mounting illustrationSupport railDimensional drawingsIllustration: front viewIllustration: side view17
UMG 104PQM - Power Quality MonitoringMore than just aMultimeterThe UMG 104 equipped with a 500 MHz DSP (digital signal processor) is a very fast and powerfulpower analyser.The continuous scanning of the 8 channels with 20 kHz per channel allows the recording of all electricalparameters (more than 800 values), minimum - and maximum - values, and the main powerquality values such as harmonics (up to the 40 th , each phase with the detection of direction).Based on these data loss of production can be avoided, concepts can be developed, such as the electricitycost reduction programs, and measures introduced. And finally the improvements can bemonitored and recorded with the UMG 104 as well.Using modern communication architectures, the acquired data are fed to a central location, in powerfuldatabases, stored centrally and made available for further processing in an open architecture. Theeasy integration into an existing building control system or PLC environment extends the capabilitiesof the UMG 104.Applications: Replacement of analogue and digital instrumentation Consumption data collection and analysis (load profiles) Continuous power quality monitoring Cost center management, i.e. breakdown of energy costs, e.g. allocation per product Remote control and monitoring of equipment and processes Protection of networks “Sensor” for building management systems or PLC18
- Page 2 and 3: “Quality is never an accident;it
- Page 4 and 5: 3▼Chapter 1Janitza electronics ®
- Page 6 and 7: 5▼Chapter 1Janitza’s ®3P-Strat
- Page 8 and 9: ▼Chapter 2Power Quality Monitorin
- Page 10 and 11: ▼Chapter 2Overview of universal m
- Page 12 and 13: 11▼Chapter 2Overview of universal
- Page 14 and 15: ▼Chapter 2Universal measuring ins
- Page 16 and 17: ▼Chapter 2Functions and technical
- Page 20: ▼▼Chapter 2Power analyserexcess
- Page 23 and 24: ▼UMG 104Technical dataSupply volt
- Page 25 and 26: UMG 604PQM - Power Quality Monitori
- Page 27 and 28: UMG 604DIN rail mounting (6 units):
- Page 30 and 31: ▼Chapter 2Product variants and te
- Page 32 and 33: ▼▼Chapter 2UMG 604Connectionill
- Page 34: ▼Chapter 2Power quality analyserU
- Page 37 and 38: ▼UMG 605Measurement valuesVoltage
- Page 39 and 40: PQM - Power Quality MonitoringUnive
- Page 41 and 42: UMG 96L / UMG 96Measurement value d
- Page 43 and 44: ▼UMG 96L / UMG 96Typical connecti
- Page 45 and 46: UMG 96SPQM - Power Quality Monitori
- Page 47 and 48: UMG 96SData storage / memoryUp to 1
- Page 50 and 51: ▼Chapter 2Product variants and te
- Page 52 and 53: ▼Chapter 2UMG 96Smax. 6Connection
- Page 54 and 55: ▼Chapter 2Power analyserUMG 503Th
- Page 57 and 58: ▼UMG 503Overview of product varia
- Page 59 and 60: ▼UMG 503PeripheryDigital inputs (
- Page 61 and 62: UMG 505PQM - Power Quality Monitori
- Page 63 and 64: UMG 505Measurement value displays a
- Page 66 and 67: ▼Chapter 2Product variants and te
UMG 104PQM - <strong>Power</strong> <strong>Quality</strong> <strong>Monitoring</strong>More than just aMultimeterThe UMG 104 equipped with a 500 MHz DSP (digital signal processor) is a very fast and powerfulpower analyser.The continuous scanning of the 8 channels with 20 kHz per channel allows the recording of all electricalparameters (more than 800 values), minimum - and maximum - values, and the main powerquality values such as harmonics (up to the 40 th , each phase with the detection of direction).Based on these data loss of production can be avoided, concepts can be developed, such as the electricitycost reduction programs, and measures introduced. And finally the improvements can bemonitored and recorded with the UMG 104 as well.Using modern communication architectures, the acquired data are fed to a central location, in powerfuldatabases, stored centrally and made available for further processing in an open architecture. Theeasy integration into an existing building control system or PLC environment extends the capabilitiesof the UMG 104.Applications: Replacement of analogue and digital instrumentation Consumption data collection and analysis (load profiles) Continuous power quality monitoring Cost center management, i.e. breakdown of energy costs, e.g. allocation per product Remote control and monitoring of equipment and processes Protection of networks “Sensor” for building management systems or PLC18