11.07.2015 Views

Power Quality Monitoring

Power Quality Monitoring

Power Quality Monitoring

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Moulded case current transformerclass 1Technical data Nominal frequency 50 Hz to 60 Hz Insulation class E (other classifications upon request) Thermal short-term current Ith = 60 x IN /1sSurge current Idyn = 2.5 x Ith, minimum100kA for all bushing type current transformersHighest voltage for materials Um = 0.72kVCalculation of insulation level (test voltage) 3kV/1 min (in accordance with EN6044-1)Overvoltage limit factor FS5 or FS10Harmonic currents up to the 50 th harmonicOverview of current transformers class 1DescriptionType (dimensionaldrawing pg 165)Primary current in ASecondary current in A<strong>Power</strong> in VAClassPrimary conductorCircular conductorConstruction widthItem numberCurrenttransformer 50/5 -1Currenttransformer 75/5 -1Currenttransformer 100/5 -1Currenttransformer 150/5 -1Currenttransformer 200/5 -1Currenttransformer 250/5 -1Currenttransformer 300/5 -1Currenttransformer 400/5 -1Currenttransformer 500/5 -1Currenttransformer 600/5 -1Currenttransformer 800/5 -1Currenttransformer 1000/5 -1Currenttransformer 1250/5 -1Currenttransformer 1500/5 -1IPA 40 50 5 2.5 1 40x10mm, 30x15mm, 25x20mm 30mm 70mm 09.05.110IPA 40 75 5 2.5 1 40x10mm, 30x15mm, 25x20mm 30mm 70mm 09.05.1126A315.3 100 5 2.5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4046A315.3 150 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4526A315.3 200 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4246A315.3 250 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4256A315.3 300 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4266A315.3 400 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4276A315.3 500 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4286A315.3 600 5 5 1 30x15mm, 20x20mm 28mm 60mm 09.00.4297A412.3 800 5 5 1 40x12mm, 2x30x10mm 33mm 70mm 09.00.9817A412.3 1000 5 5 1 40x12mm, 2x30x10mm 33mm 70mm 09.00.9828A512.3 1250 5 5 1 50x12mm, 2x40x10mm 42mm 85mm 09.01.4128A512.3 1500 5 5 1 50x12mm, 2x40x10mm 42mm 85mm 09.01.413AccessoriesSnap fixing For EN50022-35 DIN rails, suitable for IPA 30 and IPA 40 versions 09.09.000Snap fixing For EN50022-35 DIN rails, suitable for 6A315.3, 7A412.3 and 8A512.3 versions 09.09.001Secondary current transformers .../1A upon request.Dimensional drawings – refer to page 165.166

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!