Power Quality Monitoring
Power Quality Monitoring Power Quality Monitoring
▼Chapter 4Passive harmonic filter... AccessoriesController modulesItemController module with Prophi® 6R controller, 6 steps (relay outputs),Fuses, current transformer clamps and 2m connection cable(mounted on the capacitor module)Controller module with Prophi® 12R controller, 12 steps (relay outputs),Fuses, current transformer clamps and 2m connection cable(mounted on the capacitor module)Item number50.80.00350.80.004Fixing rails for extractable modules in Rittal cabinetsItemItem numberFixing rail (left) for MO84 Rittal cabinets 29.12.435▼Fixing rail (right) for MO84 Rittal cabinets 29.12.436Fixing rail (left) for MO86 Rittal cabinets 29.12.431Fixing rail (right) for MO86 Rittal cabinets 29.12.432Cabinet socketItemItem numberSocket 100mm high SO 100/800/600 29.03.325 & 326Socket 200mm high SO 200/800/600 29.03.327 & 319Harmonic analyser with Ethernet connectionItemItem numberUMG 508 With display in cabinet door 52.21.001UMG 604E Din rail mounting (inside the cabinet) 52.16.002Refer to chapter 2 for other versions137
Dynamic (fast switching)power factor correctionFor use with rapid and highload changesDynamic PFC systems are particularly used in applications with rapid and high load changes. Theseare automatically regulated systems for central compensation in low voltage distribution boards or forgroup compensation of sub-systems.De-tuned PFC systems for use in applications with non-linear loads i.e. harmonic loads.There are various designs customised to suit your individual application.138
- Page 88 and 89: ▼Chapter 2Product variants and te
- Page 90 and 91: ▼▼Chapter 3Power ManagementAn o
- Page 93 and 94: PM - Power ManagementElectronic ene
- Page 95 and 96: Product variants andtechnical dataO
- Page 97 and 98: Module technologyCommunication modu
- Page 99 and 100: Product variants andtechnical dataO
- Page 101 and 102: UMG 507EmaxPM - Power ManagementUMG
- Page 103 and 104: UMG 507EmaxFunctional principleThe
- Page 105 and 106: UMG 507EmaxUMG 507Emax product vari
- Page 107 and 108: ProData ®PM - Power ManagementProD
- Page 109: ProData ®Analogue inputs1 analogue
- Page 113: PQS - Power Quality SolutionsPQS -
- Page 117 and 118: Prophi ®power factor controllerVen
- Page 119 and 120: Prophi ®power factor controllerMea
- Page 121 and 122: PQS - Power Quality SolutionsPower
- Page 123 and 124: Can-type capacitor in aluminium hou
- Page 125 and 126: PQS - Power Quality SolutionsAutoma
- Page 127 and 128: Compact designAutomatic PFC in comp
- Page 129 and 130: Mounting plateAutomatic PFC system
- Page 131 and 132: PQS - Power Quality SolutionsDe-tun
- Page 133 and 134: De-tuned power factorcorrection (wi
- Page 135 and 136: ▼Extractable modular design7% De-
- Page 137: ▼Extractable modular designDe-tun
- Page 141 and 142: ▼Extractable modular designDe-tun
- Page 143 and 144: ▼Extractable modular design7% De-
- Page 145 and 146: ▼Capacitor modules and accessorie
- Page 147 and 148: SoftwareSoftware solutions - especi
- Page 149 and 150: GridVisSoftwareGrid visualisationfo
- Page 151 and 152: GridVisProgramming and configuratio
- Page 153 and 154: GridVisReporting and statistical fu
- Page 155 and 156: OPC serverSoftwareGLTIntranetModbus
- Page 157: MS Excel analysis toolsSoftwareCust
- Page 160 and 161: ▼Chapter 5SoftwareMS Excel VBAVBA
- Page 162 and 163: ▼▼Chapter 6AccessoriesCurrent t
- Page 164 and 165: Chapter 6AccessoriesRemote maintena
- Page 166 and 167: ▼Chapter 6Moulded case current tr
- Page 168 and 169: ▼Chapter 6Moulded case current tr
- Page 170 and 171: ▼Chapter 6Cable split core CTs▼
- Page 172 and 173: ▼Chapter 6Split core current tran
- Page 174 and 175: ▼Chapter 6Current transformersDIN
- Page 176 and 177: ▼Chapter 6Current transformer acc
- Page 178 and 179: ▼Chapter 6Mechanical accessoriesM
- Page 180 and 181: ▼Chapter 6Mechanical accessoriesA
- Page 182 and 183: ▼Chapter 6Field bus componentsDe-
- Page 184 and 185: ▼Chapter 6Field bus componentsDe-
- Page 186 and 187: ▼Chapter 6Field bus componentsAcc
Dynamic (fast switching)power factor correctionFor use with rapid and highload changesDynamic PFC systems are particularly used in applications with rapid and high load changes. Theseare automatically regulated systems for central compensation in low voltage distribution boards or forgroup compensation of sub-systems.De-tuned PFC systems for use in applications with non-linear loads i.e. harmonic loads.There are various designs customised to suit your individual application.138