11.07.2015 Views

The LOCATOR® Overdenture Abutment - Biomet 3i

The LOCATOR® Overdenture Abutment - Biomet 3i

The LOCATOR® Overdenture Abutment - Biomet 3i

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Attachment DurabilityINSERTION AND EXTRACTION TEST OF RETENTION LOSS(Cycles to 0.8 Pounds Retention)Cycles (in 1,000s)605550454035302520151050LOCATOR ®(56,000 Cycles)Sterngold ERA ®(2,000 Cycles)• Patented 1 Dual-Retention Design ProvidesApproximately Twice <strong>The</strong> Amount OfRetention Surface Area Than Only InternalRetention Attachments.• Combination Of Inside And OutsideRetention Ensures Long-LastingRetention Life.• Independent Laboratory Testing*Demonstrated 56,000 Cycles Of FunctionWith Satisfactory Retention.• Independent Laboratory Testing* ShowedThat <strong>The</strong> LOCATOR ® Male Attachment Is 28Times Longer-Lasting, As Compared To <strong>The</strong>ERA ® Implant Attachment.Angle Correction Up To 40º• Allows Correction Of Angles Up To 40˚ BetweenDivergent Implants Using <strong>The</strong> Same <strong>Abutment</strong>• Eliminates Positioning Of Angled <strong>Abutment</strong>s• Extended-Range Male Attachment Demonstrates<strong>The</strong> Same Long-Lasting Retention• Maintains A Low Vertical Height Of 3.17mm FromPlatform To Top Of Housing1 Patent No. 6,030,219, used with permission.*Delson Testing Laboratories was contracted by BIOMET <strong>3i</strong> LLC in the year 2000 to measure the retention of the LOCATOR ® MaleAttachment as compared to the ERA ® Implant Attachment. Testing was conducted on two nonsterile LOCATOR ® and ERA ® attachments.ERA ® is a registered trademark of Sterngold Attachments.


Lowest Vertical Height• A Critical Advantage Where Interocclusal SpaceIs Limited• Total <strong>Abutment</strong> And Attachment Height Is Only3.17mm With 1.0mm <strong>Abutment</strong>s3.17mm• A Full 1.68mm Lower Than <strong>The</strong> Next LowestCompetitive <strong>Abutment</strong>LOCATOR ®Easy Maintenance• Attachment Durability Means FewerMaintenance Office Visits• 3-In-1 Instrument Accomplishes AllAspects Of Attachment Replacement• <strong>Abutment</strong> Driver Is Compatible With ISO-Latch Torque Instruments Using A .050Inch (1.25mm) Hex Driver TipAttachmentRemovalAttachmentInsertion<strong>Abutment</strong>Placement• <strong>Abutment</strong>s Torqued To 20Ncm MeansReduced Loosening Complications• Triangle Driver Tip Also AvailablePatient And Practice Friendly<strong>The</strong> LOCATOR ® <strong>Abutment</strong>’s ease of use means increased patient satisfaction and its features and durabilitymean decreased maintenance visits. If your target is lower maintenance on overdenture restorations with higherpatient satisfaction, the LOCATOR ® Solution is for you!


LOCATOR ®Ordering InformationLOCATOR ® <strong>Abutment</strong>s3.4mmSeating SurfaceCollar HeightCertain ® InternalConnectionExternal HexConnectionheightheight4.1mm Seating Surfaceheightheight1mm IMLOA001 MLOA0012mm IMLOA002 MLOA0023mm IMLOA003 MLOA0034mm IMLOA004 MLOA0045mm IMLOA005 MLOA0056mm IMLOA006 MLOA0061mm ILOA001 LOA0012mm ILOA002 LOA0023mm ILOA003 LOA0034mm ILOA004 LOA0045mm ILOA005 LOA0056mm ILOA006 LOA006Included With Each <strong>Abutment</strong>:Housing And BlackProcessing MaleLOCATOR ®Extra LightRetention MaleFinal Male LOCATOR ®LightRetention MaleWhiteSpacer RingLOCATOR ® ComponentsImpression CopingRetention MalesLAIC1Laboratory AnalogReplacementMalesLARMSLightRetentionMalesLLRMSExtendedRange MalesLAERMLALA1Extra LightRetention MalesLAELMLOCATOR ® InstrumentsExtra LightExtended RangeMales LELARMLOCATOR ® Core Tool/<strong>Abutment</strong> DriverLCTDR1LOCATOR ® <strong>Abutment</strong> Driver TipLOADT4, LOADT9Hex Driver Tip 1.25mm/.050 in.RASH4 - 24mm(L)RASH9 - 30mm(L)(used with LCTDR1)


LOCATOR ® <strong>Overdenture</strong> <strong>Abutment</strong><strong>The</strong> LOCATOR ® <strong>Abutment</strong> is ideal for overdenturerestorations. Clinical use has shown that the self-locatingdesign enables patients to align and seat their overdentureswith ease. Independent laboratory testing* has shown that theLOCATOR ® <strong>Abutment</strong> maintains satisfactory retention for asmany as 56,000 cycles of function. <strong>The</strong> LOCATOR ® <strong>Abutment</strong>answers problems found with other abutments, such aslimited interocclusal space, lack of attachment durabilityand difficulty of patient insertion. At 3.17mm totalheight, LOCATOR ® is 1.68mm lower thanother available abutments.Dual Retention DesignSelf Aligninggle CorrectionAnUp To 40˚LowestVerticle HeightSelf-Aligning Design• Makes It Easier For Patients To Position AndCorrectly Seat <strong>The</strong>ir <strong>Overdenture</strong>s Into Place.• Reduces Problems Due To Insertion AndRemoval Of <strong>Overdenture</strong>s In As Little As OneOffice Visit.• Reduces Additional Wear And <strong>The</strong> DestructionOf Attachments From Improper Seating.*Delson Testing Laboratories was contracted by BIOMET <strong>3i</strong> LLC in the year 2000 to measure the retention of the LOCATOR ® MaleAttachment as compared to the ERA ® Implant Attachment. Testing was conducted on two nonsterile LOCATOR ® and ERA ® attachments.ERA ® is a registered trademark of Sterngold Attachments.


Looking For <strong>Overdenture</strong> Solutions?LOCATOR ® Is For You!For More Information, Please Contact Your LocalSales Representative Or Visitwww.biomet<strong>3i</strong>.comComprehensiveTreatmentBIOMET <strong>3i</strong>4555 Riverside DrivePalm Beach Gardens, FL 334101-800-342-5454Outside <strong>The</strong> U.S.: +1-561-776-6700Fax: +1-561-776-1272www.biomet<strong>3i</strong>.comEC REPBIOMET <strong>3i</strong>Europe, Middle East & AfricaWTC Almeda Park, Ed. 1, Planta 1ªPl. de la Pau, s/n08940, Cornellà de Llobregat(Barcelona) SpainPhone: +34-93-470-55-00Fax: +34-93-371-78-49EnhancedKnowledgeREV E 02/12BusinessExcellenceNot Available In All Markets. Please Consult Your Local BIOMET <strong>3i</strong> Sales Representative For AvailabilityScan With YourSmartphone!In order to scan QR codes,your mobile devicemust have a QR codereader installed.Certain is a registered trademark of BIOMET <strong>3i</strong> LLC. Providing Solutions - One Patient At A Time is a trademarkof BIOMET <strong>3i</strong> LLC. LOCATOR is a registered trademark of Zest Anchors, Inc. ERA is a registered trademark ofSterngold Attachments. ©2012 BIOMET <strong>3i</strong> LLC.JoinUsFollowUsWatchUsDownloadIt

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!