Guardrails » Stationary GuardrailsMegaRailN2 ∙ W4 ∙ AslEU Certificate of Conformity: 2219-CPD-0004-3/bTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.27W40.350.702.00rammed60.00.35 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsPrimus 2aN2 · W4 · ATested in accordance with DIN EN 1317, BASt no.: 2002 7 D 05/RK ∙ 2002 7 D 06/RKTECHNICAL SPECIFICATIONSDrawingConstruction width (m) 1.10Construction height (m) 0.68Distance between posts (m)variableTested system foundation / installationrammedTest length (m) 6.431.10 m0.68 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails<strong>ESP</strong> <strong>Plus</strong> 2.0N2 ∙ W4 ∙ AEU Certificate of Conformity: X53.04.H11 ∙ 0024-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W41.100.180.752.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails<strong>ESP</strong> 2.0 (B)N2 ∙ W5 ∙ AEU Certificate of Conformity: 0024-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.30W41.300.180.752.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails<strong>ESP</strong> 4.0N2 ∙ W5 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.60W51.500.180.754.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails<strong>ESP</strong> 4.0 UFSN2 ∙ W5 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.70W51.600.180.754.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail ES 1.0H1 ∙ W4 ∙ AEU Certificate of Conformity: 0047-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.80W40.700.200.751.00rammed60.00.75 m0.20 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH1 · W4 · AslEU Certificate of Conformity: 2219-CPD-0004-3/bTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.25W40.350.702.00rammed60.00.35 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail ES 1.33H1 ∙ W4 ∙ AEU Certificate of Conformity: 0081-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.10W40.900.200.751.33rammed60.00.75 m0.20 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsEDSP 1.33H1 ∙ W4 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W40.900.500.751.33rammed600.75 m0.50 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsEDSP 2.0H1 ∙ W5 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.60W51.300.500.752.00rammed60.00.75 m0.50 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 4.0H1 ∙ W6 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.90W60.800.754.00rammed60.00.80 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W3 · Bbw asphaltEU Certificate of Conformity: 0016-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.98W30.540.901.33anchored (asphalt)40.00.90 m0.67 m0.54 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W4 · BsEU Certificate of Conformity: 0015-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)1.27Class of normalised working widthW40.49 mConstruction width (m)0.49Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationrammedTest length (m)60.00.90 m0.67 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail doppeltH2 ∙ W4 ∙ BEU Certificate of Conformity: 0099-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W40.650.861.151.33rammed60.01.15 m0.75 m0.86 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail EcoH2 ∙ W4 ∙ BEU Certificate of Conformity: 0004-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)1.30Class of normalised working widthNormalised dynamic deflection (m)W40.700.45 mConstruction width (m)0.45Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco 1AH2 ∙ W4 ∙ AEU Certificate of Conformity: 0090-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working width1.30W40.45 mNormalised dynamic deflection (m)0.70Construction width (m)0.45Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.01.00 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco doppeltH2 ∙ W4 ∙ BEU Certificate of Conformity: 0020-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)1.20Class of normalised working widthNormalised dynamic deflection (m)W40.600.70 mConstruction width (m)0.70Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco MÜFH2 ∙ W4 ∙ AEU Certificate of Conformity: 0157-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working width1.30W40.45 mNormalised dynamic deflection (m)1.10Construction width (m)0.45Construction height (m)1.00Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed (asphalt)52.01.00 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail lightH2 ∙ W5 ∙ BEU Certificate of Conformity: 0091-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)1.50Class of normalised working widthNormalised dynamic deflection (m)W51.000.45 mConstruction width (m)0.45Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W5 · BdEU Certificate of Conformity: 2219-CPD-0004-4/cTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.66W50.790.752.00rammed60.00.79 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 2.0++H2 ∙ W6 ∙ AEU Certificate of Conformity:TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthConstruction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)2.00W60.800.752.00rammed80.000.80 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 1.33+SLH2 ∙ W7 ∙ AEU Certificate of Conformity: 0099-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)2.30W71.500.800.751.33rammed64.00.75 m0.80 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH3 · W4 · BsEU Certificate of Conformity: 2204-CPD-96/579/EC0130.1-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)1.29Class of normalised working widthW40.49 mConstruction width (m)0.49Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationrammedTest length (m)60.00.90 m0.67 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper RailH4b ∙ W7 ∙ AEU Certificate of Conformity: 0165-CPD-2010TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working width2.20W70.50 mNormalised dynamic deflection (m)1.90Construction width (m)0.50Construction height (m)1.15Distance between posts (m)1.33Tested system foundation / installationTest length (m)rammed76.01.15 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail doppeltH4b ∙ W4 ∙ BEU Certificate of Conformity: 0039-CPD-2011TECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W40.650.861.151.33rammed60.01.15 m0.75 m0.86 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 · W4 · AenEU Certificate of Conformity: in progressTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)W40.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH1 · W3 · Aec 3.3EU Certificate of Conformity: in progressTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.90W30.700.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W4 · Aec 4.4EU Certificate of Conformity: in progressTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.10W41.000.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W5 · AekEU Certificate of Conformity: in progressTECHNICAL SPECIFICATIONSDrawingNormalised working width (m)Class of normalised working widthNormalised dynamic deflection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.70W51.500.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>