Transition Plan


Report #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>ReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>1-Sales and ServiceCounters: <strong>Ticket</strong> <strong>Booth</strong>P5285. [Southwest frontticket counter.]2-Sales and ServiceCounters: <strong>Ticket</strong> <strong>Booth</strong>P5285. [East souvenirsstand.]3-Doors: Women'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.5-Identification Symbols,Restrooms: Women'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.A portion of the counter is a minimum of 36" inlength, at a height between 28" - 34" above thefloor and;A portion of the counter is a minimum of 36" inlength, at a height between 28" - 34" above thefloor and;5 lb. maximum pressure to operate exteriordoors. Door hardware is operable with a singleeffort (lever type, panic bar or push pull type).Women's - 12" diameter circle 1/4" thick. Thecircle symbol contrasts with the door, light ondark background or dark on light background.Wall mounted signage: Symbol of accessibilityis mounted on wall sign adjacent to latch side ofdoor [ADAAG 703.6.1 & CBC 1117B.5.5 Item 4Pictograms shall have a field height of 6"ADAAG 703.6.1 Characters and Braille shall notbe located in the pictogram field].Provide an auxiliary counterwith a maximum height of 34".Provide an auxiliary counterwith a maximum height of 34".Adjust door opening pressure /closing time unless acceptedby DSA Fire / Life Safety.Consider issues connectedwith building pressure / climatecontrol. Replace doorhardware with complianthardware.Install door-mounted sign onsingle door. Install wallmountedsign at singleentrance.2 $1,225.032 $1,225.031 $784.013 $367.515/31/2012 Page 1 of 5


Report #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>ReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5285<strong>Ticket</strong><strong>Booth</strong>9-Accessories:Women's Restroom at<strong>Ticket</strong> <strong>Booth</strong> P5285.40" max. height to all other fixtures (i.e., soapdispensers, towels, toilet seat covers, autodryers, sanitary napkins, waste recepatacles,etc.). Coat hooks and shelving are locatedwithin appropriate reach ranges (48" max.height above floor surface is recommended).Install accessible coat hook.Lower the paper toweldispenser. Lower the soapdispenser.3 $367.51UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>10-Visual/AudibleAlarms: Women'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.12-Water Fountains(Drinking): Between theMen's and Women'sRestroom.13-Doors: Men'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.14-Clear Space atDoors: Men's Restroomat <strong>Ticket</strong> <strong>Booth</strong> P5285.The alarm is integrated into the building orfacility alarm system.32" minimum wide and 18" minimum deepalcove provided. 18" - 19" depth of fountain.Stream of bubbler is parallel to front edge. 4"minimum height of stream. The force required toactivate controls does not exceed 5lbf.5 lb. maximum pressure to operate exteriordoors. Door hardware is operable with a singleeffort (lever type, panic bar or push pull type).Minimum strike side clearance on PUSH side ofdoor: 12" front approach with latch and closer.Review the entire alarmsystem.Install new HI-LO drinkingfountain. Install canedetectablebarrier aroundfountain.Adjust door opening pressure /closing time unless acceptedby DSA Fire / Life Safety.Consider issues connectedwith building pressure / climatecontrol. Replace doorhardware with complianthardware.Relocate the paper toweldispenser.1 $7,115.622 $8,149.34 Defer.1 $784.011 $122.51UCR P5285<strong>Ticket</strong><strong>Booth</strong>15-IdentificationSymbols, Restrooms:Men's Restroom at<strong>Ticket</strong> <strong>Booth</strong> P5285.Door mounted signage: Men's - Equilateraltriangle with 12" sides, 1/4" thick with the vertexpointing up. The triangle symbol contrasts withthe door, light on dark background or dark onlight background. Wall mounted signage:Symbol of accessibility is mounted on wall signadjacent to latch side of door [ADAAG 703.6.1 &CBC 1117B.5.5 Item 4 Pictograms shall have afield height of 6" ADAAG 703.6.1 Charactersand Braille shall not be located in the pictogramfield].Install door-mounted sign onsingle door. Install wallmountedsign at singleentrance.3 $367.515/31/2012 Page 3 of 5


Report #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>ReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5285<strong>Ticket</strong><strong>Booth</strong>16-MultipleAccommodation Toilets:Men's Restroom at<strong>Ticket</strong> <strong>Booth</strong> P5285.Door latch is a flip-over style, sliding or otherhardware not requiring tight grasping or twisting.Door has loop or U-shaped handle immediatelybelow latch on both inside and outside of door.If the compartment has an end opening outwardswingingdoor (facing the water closet), aminimum 60" wide x 48"deep clear floor spaceis provided in front of the water closet. 60"minimum width of stall [ADAAG 604.8.1.4 toeclearances - The front partition and at least oneside partition shall provide a toe clearance of 9inches minimum above the finish floor and 6inches deep minimum beyond the compartmentside face of the partition exclusive of partitionsupport members]. 32" minimum from side ofwater closet to opposite wall or partition. 42"minimum from centerline of water closet toopposite wall or partition. The toilet paperdispenser is located on the side wall below thegrab bar and within 7" - 9" of the front of thetoilet seat as measured to the centerline of thedispenser.Requiresengineering/architecturalevaluation. Relocate toiletpartition. Install stall doorhardware. Relocate the toiletpaper dispenser away from thetop of the grab bar.3 $9,086.60UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>UCR P5285<strong>Ticket</strong><strong>Booth</strong>17-Toilet Grab Bars:Men's Restroom at<strong>Ticket</strong> <strong>Booth</strong> P5285.18-Lavatories: Men'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.19-Urinals: Men'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.The front of the side grab bar extends 52" fromback wall in multiple accommodation restroom.Area directly above grab bars or proposed grabbars is free of protruding obstructions to aheight of 18" (recessed items are allowed).30" x 48" min. clear space provided in front oflavatory that allows forward approach (doorsmay not encroach into this space). 27" high x 8"deep knee clearance under front lip. Drain andpiping is insulated or configured to preventcontact.17" maximum urinal rim height above thefinished floor. 14" minimum projection and 17"maximum projection from the wall. 44"maximum height to flush valve above finishedfloor.Replace with two grab bars.Relocate the seat coverdispenser away from the top ofthe grab bar. Continuous grabbar. See Sequence #16 foradditional actions.Raise existing lavatory.Insulate pipes under lavatory.3 $857.523 $2,450.05Replace with accessible urinal. 3 $3,185.075/31/2012 Page 4 of 5


Report #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>ReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5285<strong>Ticket</strong><strong>Booth</strong>20-Accessories: Men'sRestroom at <strong>Ticket</strong><strong>Booth</strong> P5285.40" max. height to all other fixtures (i.e., soapdispensers, towels, toilet seat covers, autodryers, sanitary napkins, waste recepatacles,etc.). Coat hooks and shelving are locatedwithin appropriate reach ranges (48" max.height above floor surface is recommended).Install accessible coat hook.Lower the paper toweldispenser. Lower the soapdispenser.3 $367.51Grand Total $81,155.525/31/2012 Page 5 of 5


Cost Report


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue Qty UnitSubContractorSubTotal(10%)ConcealedConditions(12.5%)SecurityConditions(15%)GeneralConditionsTotal1. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Lower 36” wide counter section or provide an auxiliary counterwith a maximum height of 34”.1 ea. $860.80 $860.80 $946.88 $1,065.24 $1,225.03 $1,225.03TOTAL EST: $1,225.032. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Lower 36” wide counter section or provide an auxiliary counterwith a maximum height of 34”.1 ea. $860.80 $860.80 $946.88 $1,065.24 $1,225.03 $1,225.03TOTAL EST: $1,225.033. Doors - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26by DSA / Fire Life Safety.Replace door hardware with compliant hardware. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76TOTAL EST: $784.025. Identification Symbols, Restrooms - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Install door-mounted sign on single door. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75TOTAL EST: $367.506. Multiple Accommodation Toilets - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62Provide major renovation (including moving plumbing locations 75 s.f. $320.00 $24,000.00 $26,400.00 $29,700.00 $34,155.00 $34,155.00and walls).TOTAL EST: $41,270.62Page 1 of 4


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue Qty UnitSubContractorSubTotal(10%)ConcealedConditions(12.5%)SecurityConditions(15%)GeneralConditionsTotal7. Toilet Grab Bars - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Replace/Install grab bar. 2 ea. $258.24 $516.48 $568.13 $639.15 $735.02 $735.02Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51bars or proposed grab bars.Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51bars or proposed grab bars.TOTAL EST: $980.048. Lavatories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01TOTAL EST: $2,450.059. Accessories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Install accessible coat hook. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51TOTAL EST: $367.5312. Water Fountains (Drinking) - Between the Men’s and Women’s Restroom.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Install new HI-LO drinking fountain. 1 ea. $4,900.00 $4,900.00 $5,390.00 $6,063.75 $6,973.31 $6,973.31Install cane-detectable barrier around fountain. 2 ea. $413.18 $826.36 $909.00 $1,022.62 $1,176.01 $1,176.01TOTAL EST: $8,149.32Page 2 of 4


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue Qty UnitSubContractorSubTotal(10%)ConcealedConditions(12.5%)SecurityConditions(15%)GeneralConditionsTotal13. Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Adjust door for opening pressure/closing times unless accepted 1 ea. $215.20 $215.20 $236.72 $266.31 $306.26 $306.26by DSA / Fire Life Safety.Replace door hardware with compliant hardware. 1 ea. $335.71 $335.71 $369.28 $415.44 $477.76 $477.76TOTAL EST: $784.0214. Clear Space at Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 2RECOMMENDATIONS AND RETROFIT COSTS:Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51TOTAL EST: $122.5115. Identification Symbols, Restrooms - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Install door-mounted sign on single door. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75Install wall-mounted sign at single entrance. 1 ea. $129.12 $129.12 $142.03 $159.78 $183.75 $183.75TOTAL EST: $367.5016. Multiple Accommodation Toilets - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Requires engineering/architectural evaluation. 1 ea. $5,000.00 $5,000.00 $5,500.00 $6,187.50 $7,115.62 $7,115.62Relocate toilet partition. 2 ea. $520.32 $1,040.64 $1,144.70 $1,287.79 $1,480.96 $1,480.96Replace/Install stall door hardware. 1 ea. $258.24 $258.24 $284.06 $319.57 $367.51 $367.51Relocate the toilet paper dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51bars or proposed grab bars.TOTAL EST: $9,086.60Page 3 of 4


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue Qty UnitSubContractorSubTotal(10%)ConcealedConditions(12.5%)SecurityConditions(15%)GeneralConditionsTotal17. Toilet Grab Bars - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Replace/Install grab bar. 2 ea. $258.24 $516.48 $568.13 $639.15 $735.02 $735.02Relocate the seat cover dispenser away from the top of the grab 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51bars or proposed grab bars.TOTAL EST: $857.5318. Lavatories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Raise/Lower existing lavatory. 1 ea. $1,549.44 $1,549.44 $1,704.38 $1,917.43 $2,205.04 $2,205.04Insulate pipes under lavatory (or sink when applicable). 1 ea. $172.16 $172.16 $189.38 $213.05 $245.01 $245.01TOTAL EST: $2,450.0519. Urinals - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Replace/Install urinal. 1 ea. $2,238.08 $2,238.08 $2,461.89 $2,769.63 $3,185.07 $3,185.07TOTAL EST: $3,185.0720. Accessories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Priority: 3RECOMMENDATIONS AND RETROFIT COSTS:Install accessible coat hook. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51Relocate the paper towel dispenser / hand dryer. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51Relocate the soap dispenser. 1 ea. $86.08 $86.08 $94.69 $106.53 $122.51 $122.51TOTAL EST: $367.53REPORT TOTALS: $52,026.26 $57,228.89 $64,382.50 $74,039.88 $74,039.88Page 4 of 4


Survey


Americans with Disabilities Act of 1990Site Assessment ReportReport: UCR P5285 <strong>Ticket</strong><strong>Booth</strong>900 University AvenueRiverside, CA 92521Inspection Date: 08/17/2009Prepared for:University of California at RiversidePrepared by:National Access Consultants, LLC2321 Abbot Kinney Blvd. Suite 200Venice, California 90291(805)497-6116


Contents1. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23. Doors - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . . 34. Clear Space at Doors - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.a . . . . . . . . . . . . . . . . . 55. Identification Symbols, Restrooms - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . 76. Multiple Accommodation Toilets - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . 87. Toilet Grab Bars - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . 118. Lavatories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . 139. Accessories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . 1510. Visual/Audible Alarms - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . 1711. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. 1812. Water Fountains (Drinking) - Between the Men’s and Women’s Restroom. . . . . . . . . . . . . . . 2013. Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2214. Clear Space at Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . 2415. Identification Symbols, Restrooms - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . 2616. Multiple Accommodation Toilets - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . 2717. Toilet Grab Bars - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . 3018. Lavatories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . 3219. Urinals - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3420. Accessories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . . . . . . . 3521. Visual/Audible Alarms - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . . . . . . . . . . . . . . . . . . 3622. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285. . . 37


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue1. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Southwest front ticket counter.Areas noted in compliance:A minimum 30” x 48” clear space is provided at the counter and;One full unobstructed side of the clear floor space adjoins or overlaps an accessible route.Areas not meeting new construction standards:A portion of the counter is a minimum of 36” in length, at a height between 28” - 34” above the floor and; (42-1/2”high.)Recommendation:Lower 36” wide counter section or provide an auxiliary counter with a maximum height of 34”.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-1-1 (originally 0028)1


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue2. Sales and Service Counters - <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:East souvenirs stand.Areas noted in compliance:A minimum 30” x 48” clear floor space is provided at the counter and;One full unobstructed side of the clear floor space adjoins or overlaps an accessible route.Areas not meeting new construction standards:A portion of the counter is a minimum of 36” in length, at a height between 28” - 34” above the floor and; (41”.)Recommendation:Lower 36” wide counter section or provide an auxiliary counter with a maximum height of 34”.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-2-1 (originally 0029)2


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue3. Doors - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:Opens a min. of 90 degrees.1/4” maximum vertical threshold or 1/2” beveled at 1:2.32” minimum clear width of doorway.Hardware is 30” to 44” above floor.3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to beopened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).Areas not meeting new construction standards:5 lb. maximum pressure to operate exterior doors. (9 lbs.)Door hardware is operable with a single effort (lever type, panic bar or push pull type). (Knobs.)Recommendation:Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.Replace door hardware with compliant hardware.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-3-1 (originally 0030)3


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-3-2 (originally 0031)4


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue4. Clear Space at Doors - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.aMemo:Areas noted in compliance:Floor or landing is level and clear (2% max. slope).60” min. clear space in direction of door swing.44” min. clear space opposite direction of door swing (48” with latch and closer).Minimum strike side clearance on PULL side of door: 24” exterior doors.Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.Areas not meeting new construction standards:None observed.Recommendation:None.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-4-1 (originally 0032)5


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-4-2 (originally 0034)6


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue5. Identification Symbols, Restrooms - Women’s Restroom at <strong>Ticket</strong><strong>Booth</strong> P5285.Memo:Areas noted in compliance:None observed.Areas not meeting new construction standards:Women’s - 12” diameter circle 1/4” thick. The circle symbol contrasts with the door, light on dark background or darkon light background. (None.)Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door.Recommendation:Install door-mounted sign on single door.Install wall-mounted sign at single entrance.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-5-1 (originally 0035)7


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue6. Multiple Accommodation Toilets - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong>P5285.Memo:Areas noted in compliance:60” min. diameter turning circle clear of objects from floor height to 27” in room.44” min. clear path provided throughout facility.32” minimum opening at end.The clear floor area on the pull side of the door is the width of the door and a minimum 60” deep.The clear floor area on the strike side of the door is a minimum 18” wide and a minimum 60” deep.The clear floor area on the push side of the door within the stall is the width of the door and a minimum 48” deep.44” maximum height to flush valve and 5 lb maximum force to operate the flush valve.Front of toilet paper dispenser is within 36” of back wall.The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toiletseat.19” minimum height to toilet paper dispenser.Toilet paper dispenser provides continuous flow.Areas not meeting new construction standards:3 second min. automatic closing door. (Does not close.)Door latch is a flip-over style, sliding or other hardware not requiring tight grasping or twisting.Door has loop or U-shaped handle immediately below latch on both inside and outside of door. (None inside.)If the compartment has an end opening door (facing the water closet), a minimum 60” wide x 48”deep clear floorspace is provided in front of the water closet. (44” wide x 28” deep.)60” minimum width of stall. (36”.)18” betwen centerline of water closet and side wall or partition. (16”.)32” minimum from side of water closet to opposite wall or partition. (8”.)42” minimum from centerline of water closet to opposite wall or partition. (20”.)The top of the toilet seat is 17” - 19” from the floor surface as measured to the top of a maximum 2” high toiletseat (a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high). (16”.)Flush valve is on wide side of the water closet.8


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenueRecommendation:Requires engineering/architectural evaluation.Provide major renovation (including moving plumbing locations and walls).Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-6-1 (originally 0036)Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-6-2 (originally 0037)9


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-6-3 (originally 0038)10


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue7. Toilet Grab Bars - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Continuous grab bar.Areas noted in compliance:1-1/4” to 1-1/2” diameter of bars.1-1/2” clearance between bars and each wall or partition.The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.(32-1/2”.)The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (fortank type toilets, 36” may be allowed if tank obstructs placement of bar). (32-1/2”.)Side bar has 42” min. length.Side bar begins a max. of 12” from back wall.Back bar begins a max. of 6” from side wall.Bars are smooth with a min. edge radius of 1/8”.Grab bars do not rotate within their fittings.Min. structural strength to support 250 lb. point load.Surface of wall adjacent to grab bars are free of sharp or abrasive elements.Areas not meeting new construction standards:The front of the side grab bar extends 52” from back wall in multiple accommodation restroom. (46-1/2”.)Back bar has 36” min. length. (29-3/4”.)Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recesseditems are allowed). (Toilet paper dispenser - 3-1/2” / seat cover dispenser - 6-3/4”.)Recommendation:Replace/Install grab bar.Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.11


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-7-1 (originally 0039)12


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue8. Lavatories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into thisspace).Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.18” minimum from center of fixture to side wall or partition.34” max. height to rim or counter above floor surface.29” min. clearance from bottom of apron to floor surface.30” wide x 9” high x 17” deep clearance from front of lavatory.There are no sharp or abrasive elements under lavatory.Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.5 lb. max. force required to operate controls.Areas not meeting new construction standards:27” high x 8” deep knee clearance under front lip. (26” high.)Drain and piping is insulated or configured to prevent contact.Recommendation:Raise/Lower existing lavatory.Insulate pipes under lavatory (or sink when applicable).13


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-8-1 (originally 0040)14


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue9. Accessories - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:40” maximum height to bottom of reflective surface of mirror.Accessories do not require tight grasping, pinching or twisting of the wrist to operate.A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.A maximum of 5 lbs. force is required to operate mechanisms.Areas not meeting new construction standards:40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, wasterecepatacles, etc.). (Paper towel dispensers - 46-1/2” - 49-1/2” / soap dispensers - 43” - 44”.)height above floor surface is recom-Coat hooks and shelving are located within appropriate reach ranges (48” max.mended). (67” high.)Recommendation:Install accessible coat hook.Relocate the paper towel dispenser / hand dryer.Relocate the soap dispenser.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-9-1 (originally 0041)15


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-9-2 (originally 0043)16


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue10. Visual/Audible Alarms - Women’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:See Sequence #10 for recommendation.Areas noted in compliance:None observed.Areas not meeting new construction standards:The alarm is integrated into the building or facility alarm system. (None.)Recommendation:None.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-10-1 (originally 0044)17


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue11. Electrical Controls & Receptacles/Fire Alarm Boxes - Women’sRestroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”max. above the floor or working platform. (50”.)The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the flooror working platform.Areas not meeting new construction standards:None observed.Recommendation:None.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-11-1 (originally 0045)18


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-11-2 (originally 0048)19


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue12. Water Fountains (Drinking) - Between the Men’s and Women’sRestroom.Memo:Areas noted in compliance:27” high x 8” deep clear knee space under fountain.9” high x 17” deep toe clearance.Lever or push bar control is located 6” max. from front edge.Bubbler outlet is 6” maximum from front.Bubbler outlet is 36” maximum from floor.Two fountains are provided, one that is wheelchair accessible and one at normal height for those persons having difficultybending or stooping.Areas not meeting new construction standards:32” minimum wide and 18” minimum deep alcove provided. (No alcove.)18” minimum depth of fountain. (12-1/2”.)Stream of bubbler is parallel to front edge.4” minimum height of stream. (2-1/2”.)The force required to activate controls does not exceed 5lbf. (12 lbs.)Recommendation:Install new HI-LO drinking fountain.Install cane-detectable barrier around fountain.20


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-12-1 (originally 0049)21


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue13. Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:Opens a min. of 90 degrees.1/4” maximum vertical threshold or 1/2” beveled at 1:2.32” minimum clear width of doorway.Hardware is 30” to 44” above floor.3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch.Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to beopened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).Areas not meeting new construction standards:5 lb. maximum pressure to operate exterior doors. (11 lbs.)Door hardware is operable with a single effort (lever type, panic bar or push pull type). (Knobs.)Recommendation:Adjust door for opening pressure/closing times unless accepted by DSA / Fire Life Safety.Replace door hardware with compliant hardware.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-13-1 (originally 0050)22


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-13-2 (originally 0051)23


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue14. Clear Space at Doors - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:Floor or landing is level and clear (2% max. slope).60” min. clear space in direction of door swing.44” min. clear space opposite direction of door swing (48” with latch and closer).Minimum strike side clearance on PULL side of door: 24” exterior doors.Areas not meeting new construction standards:Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer. (11” to the paper toweldispenser.)Recommendation:Relocate the paper towel dispenser / hand dryer.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-14-1 (originally 0052)24


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-14-2 (originally 0053)25


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue15. Identification Symbols, Restrooms - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong>P5285.Memo:Areas noted in compliance:None observed.Areas not meeting new construction standards:Door mounted signage: Men’s - Equilateral triangle with 12” sides, 1/4” thick with the vertex pointing up. The trianglesymbol contrasts with the door, light on dark background or dark on light background.Wall mounted signage: Symbol of accessibility is mounted on wall sign adjacent to latch side of door.Recommendation:Install door-mounted sign on single door.Install wall-mounted sign at single entrance.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-15-1 (originally 0054)26


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue16. Multiple Accommodation Toilets - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong>P5285.Memo:Areas noted in compliance:60” min. diameter turning circle clear of objects from floor height to 27” in room.44” min. clear path provided throughout facility.3 second min. automatic closing door.32” minimum opening at end.The clear floor area on the pull side of the door is the width of the door and a minimum 60” deep.The clear floor area on the strike side of the door is a minimum 18” wide and a minimum 60” deep.The clear floor area on the push side of the door within the stall is the width of the door and a minimum 48” deep.18” betwen centerline of water closet and side wall or partition. (17-1/2” (within dimensional tolerance).)The top of the toilet seat is 17” - 19” from the floor surface as measured to the top of a maximum 2” high toiletseat (a 3” high seat shall be permitted only in alterations where the existing fixture is less than 15” high).Flush valve is on wide side of the water closet.44” maximum height to flush valve and 5 lb maximum force to operate the flush valve.Front of toilet paper dispenser is within 36” of back wall.19” minimum height to toilet paper dispenser.Toilet paper dispenser provides continuous flow.Areas not meeting new construction standards:Door latch is a flip-over style, sliding or other hardware not requiring tight grasping or twisting.Door has loop or U-shaped handle immediately below latch on both inside and outside of door. (None inside.)If the compartment has an end opening door (facing the water closet), a minimum 60” wide x 48”deep clear floorspace is provided in front of the water closet. (49” wide x 35” deep.)60” minimum width of stall. (49”.)32” minimum from side of water closet to opposite wall or partition. (19”.)42” minimum from centerline of water closet to opposite wall or partition. (26”.)The toilet paper dispenser is located on the side wall below the grab bar and within 12” of the front of the toiletseat.27


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenueRecommendation:Requires engineering/architectural evaluation.Relocate toilet partition.Replace/Install stall door hardware.Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-16-1 (originally 0055)28


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-16-2 (originally 0056)29


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue17. Toilet Grab Bars - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Continuous grab bar. See Sequence #16 for additional recommendations.Areas noted in compliance:1-1/4” to 1-1/2” diameter of bars.1-1/2” clearance between bars and each wall or partition.The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.(32-1/4”.)The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (fortank type toilets, 36” may be allowed if tank obstructs placement of bar). (32-1/4”.)Side bar has 42” min. length.Side bar begins a max. of 12” from back wall.Back bar has 36” min. length.Back bar begins a max. of 6” from side wall.Bars are smooth with a min. edge radius of 1/8”.Grab bars do not rotate within their fittings.Min. structural strength to support 250 lb. point load.Surface of wall adjacent to grab bars are free of sharp or abrasive elements.Areas not meeting new construction standards:The front of the side grab bar extends 52” from back wall in multiple accommodation restroom. (50-1/2”.)Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recesseditems are allowed). (Toilet paper dispenser - 3-3/4” / seat cover dispenser - 6-3/4”.)Recommendation:Replace/Install grab bar.Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.30


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-17-1 (originally 0057)31


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue18. Lavatories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:Required clear space extends 19” max. underneath the lavatory and adjoins or over laps an accessible route.18” minimum from center of fixture to side wall or partition.34” max. height to rim or counter above floor surface.29” min. clearance from bottom of apron to floor surface.30” wide x 9” high x 17” deep clearance from front of lavatory.There are no sharp or abrasive elements under lavatory.Faucets are lever type, electronically activated or approved self closing valves (10 second open flow).Faucets are operable with one hand and do not require tight grasping, pinching or twisting of wrist.5 lb. max. force required to operate controls.Areas not meeting new construction standards:30” x 48” min. clear space provided in front of lavatory that allows forward approach (doors may not encroach into thisspace).27” high x 8” deep knee clearance under front lip. (25” high.)Drain and piping is insulated or configured to prevent contact.Recommendation:Raise/Lower existing lavatory.Insulate pipes under lavatory (or sink when applicable).32


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University AvenuePhoto #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-18-1 (originally 0058)33


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue19. Urinals - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:A clear floor space that is a minimum 30” wide by 48” deep is provided in front of the urinal to allow forward approach.5 lb max. pressure to operate valve.Walls within 24” of front and sides of urinals are smooth, hard and non-absorbent to 48” height, and are not adverselyaffected by moisture.Areas not meeting new construction standards:17” maximum urinal rim height above the finished floor. (24-3/4”.)14” minimum projection and 17” maximum projection from the wall. (12-1/2”.)44” maximum height to flush valve above finished floor. (52-1/2”.)Recommendation:Replace/Install urinal.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-19-1 (originally 0059)34


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue20. Accessories - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:40” maximum height to bottom of reflective surface of mirror.Accessories do not require tight grasping, pinching or twisting of the wrist to operate.A minimum 30” x 48” minimum clear floor or ground space is provided to allow forward or parallel approach to accessories.A maximum of 5 lbs. force is required to operate mechanisms.Areas not meeting new construction standards:40” max. height to all other fixtures (i.e., soap dispensers, towels, toilet seat covers, auto dryers, sanitary napkins, wasterecepatacles, etc.). (Paper towel dispensers - 46-1/2” - 49-1/4” / soap dispensers - 42” - 44”.)height above floor surface is recom-Coat hooks and shelving are located within appropriate reach ranges (48” max.mended). (67”.)Recommendation:Install accessible coat hook.Relocate the paper towel dispenser / hand dryer.Relocate the soap dispenser.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-20-1 (originally 0060)35


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue21. Visual/Audible Alarms - Men’s Restroom at <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:See Sequence #10 for recommendation.Areas noted in compliance:None observed.Areas not meeting new construction standards:The alarm is integrated into the building or facility alarm system.Recommendation:None.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-21-1 (originally 0061)36


University of California at RiversideSite Evaluation SurveyReport: UCR P5285 <strong>Ticket</strong> <strong>Booth</strong> in Riverside, CA900 University Avenue22. Electrical Controls & Receptacles/Fire Alarm Boxes - Men’s Restroomat <strong>Ticket</strong> <strong>Booth</strong> P5285.Memo:Areas noted in compliance:The center of electrical receptacles or controls, and switches to control lighting, heating, cooling & appliances are 48”max. above the floor or working platform.The center of electrical outlets intended to be used by the room occupant are located a min. of 15” above the flooror working platform. (50”.)Areas not meeting new construction standards:None observed.Recommendation:None.Photo #UCR P5285 <strong>Ticket</strong> <strong>Booth</strong>-22-1 (originally 0062)37