LANscape® SolutionsFutureCom Copper Products CatalogIssue 1, EMEACorningCable Systems


Table of contents1 Introduction 32 FutureCom F System 133 FutureCom 10 TEN System 414 FutureCom E System 555 FutureCom D System 816 FutureCom UE System 1017 FutureCom UD System 1158 Hardware 1279 Telephone / ISDN Products 16510 Cable for Patch Cords 16911 Industrial Cable 175FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordSpecialCableIndustrialCable12 Special Cable 183Further<strong>Information</strong>13 Further <strong>Information</strong> 205Corning Cable Systems1


LANscape and UniCam are registered trademarks of CorningCable Systems Brands, Inc. FutureCom, FutureLink, Pretium,FutureCom 10 TEN , LSZH and Plug & Play are trademarks ofCorning Cable Systems Brands, Inc. Discovering BeyondImagination is a registered trademark of CorningIncorporated. All other trademarks are the properties oftheir respective owners. Corning Cable Systems is ISO9001and ISO 14001 certified.2 Corning Cable Systems


Table of contents1 Introduction 31.1. Corning - A Reliable Partner 41.2. Corning Quality 51.3. Corning Cable Systems Global Locations 61.4. Standards for Structured Cabling 81.5. System Description1.5.1. LANscape® Structured Cabling 9Further<strong>Information</strong>FutureCom 10 TENFutureCom ESpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom F IntroductionCorning Cable Systems3


Corning QualityCorning Incorporated is a diversified technology companywith a proud history of developing breakthrough <strong>technologies</strong>that significantly improve people’s lives. We have beenchanging the world through innovation for more than 150years, integrating scientific discovery with market need. Wefocus on high-impact growth opportunities in the telecommunications,flat panel display, environmental, life sciencesand semiconductor industries.Corning is a reliable partner that meets the communicationrequirements of its customers all over the world with costeffectivesolutions.In 2000 Corning grouped all its cable, hardware and equipmentbusinesses into the Corning Cable Systems division.Corning Cable Systems now comprises the former SiecorCorporation, the communication cables business from BICC(Corning Cables), Siemens’ former Communication Cablesdivision and RXS Kabelgarnituren. Norddeutsche Seekabelwerke(NSW) also belongs to Corning Incorporated and iscontinuing to operate as a separate company.Corning’s own complete system for structured cabling, onthe basis of copper cable, followed in 1990. Since then, Corninghas always been a market leader and the technologyleader for cabling systems. In 1995, for the first time in theworld, Corning started using 600 MHz technology for symmetricalcopper cabling systems.Today, with LANscape® FutureCom, Corning offers a completesystem of copper components with bandwidths of 100to 1500 MHz and the experience of installing more than15 million ports. This can also be combined with modularfiber optic hardware and FutureCom cable components.LANscape - the combination of FutureCom copper andfiber optic products - thus offers the optimal solution forevery network.Our quality and environmental management systems arecertified to DIN EN ISO 9001 and ISO 14001. Our global presenceis your gain because, wherever you are, Corning is closeat hand.In the field of fiber optic cable technology, Corning was oneof the original pioneers, with expertise second to none. Asearly as 1974, when fiber optic technology was still in its infancy,Corning was working with Europe’s leading PublicTelecommunications companies in developing trial fiber opticroutes. The end of the 90s saw the beginning of localnetworks on the basis of today’s network protocols - andCorning was actively involved from the start.4 Corning Cable Systems


Corning QualityCorning Cable Systems is committed to providing excellent productquality and customer support services.Further<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems5


Corning Cable Systems GlobalCable and Hardware BusinessesHeadquarter,Hickory NC,USAWinston-Salem,NC, USAWhiston, Great BritainDerby, Great BritainAberdeen,Great BritainDeeside,WalesFavières, FranceMadrid,SpainHagen,GermanyNordenham,GermanyBerlin,GermanyNeustadt,GermanyLodz,PolandMunich,GermanyTurin, ItalyKeller, TX, USAReynosa,MexicoBoca Raton,FL, USASanto Domingo,Dominican RepublicRio Grande,Puerto Rico6 Corning Cable Systems


Corning Cable Systems Global Headquarters is located inHickory, North Carolina, USA.Corning Cable Systems EMEA Headquarters is located inBerlin, Germany.FutureCom EHardware FutureCom UD FutureCom UE FutureCom DFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableTelephone /ISDN ProductsFutureCom 10 TENFutureCom F IntroductionMoscow,RussiaGebze, TürkeiAmman,JordanBangkok,ThailandKuala Lumpur,MalaysiaSingapore,SingaporeTokyo, JapanShanghai,ChinaMakati City,PhillipinesClayton,AustraliaCorning Cable Systems7


Standards for Structured PremisesCabling SolutionsThe requirements of future-proof and flexible structured cabling are largely determined by three fundamental cablingstandards addressing specific geographic regions:StandardDescriptionEuropeEN 50173-1 (2003)Cabling Standard <strong>Information</strong> TechnologyGeneric Cabling SystemsNorth AmericaTIA/EIA 568 B. 1 (2001) / B.2 1 (2001) Commercial Building TelecommunicationsCabling StandardWorldISO/IEC 11801 Edition 2002 Cabling Standard, Generic Cabling forCustomer PremisesThe TIA/EIA is not a standard as such, but an industry specification in the North American market. It also containsrequirements regarding the transmission characteristics of cabling and components that differ from those of the EN or ISO/IEC. It has its origins in the specification of unshielded copper components.CampusdistributorBuildingdistributorFloordistributorTelecommunicationoutletTerminalequipmentFiberFiber (copper) Copper / Fiber Copper / Fiber1500 m500 m 90 mCampus Backbone Building Backbone Horizontal Substystem100 m incl. patch and connecting cords8 Corning Cable Systems


LANscape® Structured CablingBuilding cabling can utilize cabling with both symmetrical copper cables and components and fiber optic cables andcomponents. In the primary area, only fiber optic cables and components are used.Campus BackboneHorizontal SubsystemFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableFutureCom F IntroductionCampus cabling (backbone) links the individual buildings inone location with each other. The campus distributor formsthe center of primary cabling. Due to the relatively longtransmission paths, only fiber optic cabling is worth considering.Corning offers a fiber optic modular cabling solutionwhich can be combined with copper-component cabling systems.For the campus environment, mainly single-modefiber cable is used, which distinguishes itself by its low attenuationand high bandwidth. A further argument for fiberoptic cable in this area is its electromagnetic insensitivity.Building BackboneThe connection between the building distributor and thevarious horizontal distributors is designated as the secondaryarea. It represents the backbone of the building. The cablingof the vertical area can be carried out with both symmetricalcopper cables and fiber optic cables. “High-end”copper data cable (bandwidths up to 1500 MHz), such asthose you can find in the Corning FutureCom productrange, can also be used in the secondary area for lengths upto 100 m.For increased bandwidth requirements, fiber optic cables(generally multi-mode fiber cables) are recommended inthis area for greater future security .In the horizontal subsystem, mainly copper cable is used.The cabling is installed in a star shape radiating out fromthe horizontal distributor to the individual connectionboxes. The distance, however, should not exceed 90 m, sincethe cabling would then no longer comply with the standard.An additional option in the horizontal area is “fiber to thedesk” (FTTD), i.e. fiber optic cabling to the workstation. Thisis used for high bandwidth or long distance centralizedcabling applications.Corning Cable Systems9


LANscape® Structured Building CablingHorizontal Subsystem:FutureCom Outlets and Outlet Accessories(see pages 128-143)Horizontal Subsystem:FutureCom Data Cables S/FTP, F/FTP, SF/UTP, F/UTPor UTP(see system chapters in this catalog)10 Corning Cable Systems


Horizontal Subsystem:FutureCom Floor Distributors(see pages 144-151)FutureCom F IntroductionFutureCom 10 TENCampus Backbone – Building Distributor:19“ Patch Panels(see pages 152-156 or the LANscapeFiber OpticCatalog, EUR-220-EN)FutureCom EFutureCom DTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableHardwareFutureCom UDFutureCom UECampus Backbone – Backbone Cabling:Fiber Optic Cables(see the LANscape Fiber Optic Catalog,EUR-220-EN)Building Backbone – Horizontal Distributor:FutureCom 19“ Distribution Panelsor 19“ Patch Panels(see pages 152-156 or the LANscape® Fiber OpticCatalog, EUR-220-EN)Building Backbone – Vertical Area Cabling:Fiber Optic Cable or FutureCom S/FTP, F/FTP, SF/UTP, F/UTP(see the LANscape Fiber Optic Catalog or system chaptersin this catalog)SpecialCableFurther<strong>Information</strong>Corning Cable Systems11


12 Corning Cable Systems


Table of contents2 FutureCom F2.1. System Descriptions & Data 142.2. Certificates 172.3. Cable2.3.1. Cat 7. S/FTP 1500/22 and S/FTP 1200/22 Cables 182.4. Connecting Hardware2.4.1. S1200 Modules and Connectors Overview 212.4.2. Modules and Module Accessories 222.4.3. S1200 Connectors 232.4.4. Tools 252.5. Hardware2.5.1. Outlets and Outlet Accessories 262.5.2. Floor Box Solutions 292.5.3. Patch Panels 312.5.4. Consolidation Point Housing for S1200 Module 322.6. Patch Cords2.6.1. Cat. 7 Patch Cords 332.6.2. Cat. 6 Patch Cords 342.6.3. Cat. 5 Patch Cords 352.6.4. UTP Flex Patch PVC Cords 372.6.5. TV Connecting Cable 382.7. Plug & Play 392.8. Test Adapter Cable 40FutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableFurther<strong>Information</strong>SpecialCableFutureCom F IntroductionCorning Cable Systems13


FutureCom F SystemFutureCom F (2002) is Corning’s high-end system solution for symmetrical copper cabling. It satisfies all the requirements ofthe current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards for Class F links and Category 7 for the components. TheFutureCom F System is part of the Pretium Solutions family. Pretium Solutions is Corning Cable Systems’ high preformancesolution set for fiber and copper premises networks.Face Plate“DELTAprofil”,80x80 mmWAXWSE-00001-C001and S1200 Frame Set,for twoS1200 Modules, Cat.7,inclined,CAXFSE-S0201-C001FutureComS/FTP 1200/22CCXFCB-L0047-C001-L7S1200 Module,1xS1200, shielded,Cat. 7CAXFSM-00100-C001S/FTP flex/26, rot,1xS1200/4 and1xRJ45- connector,4 pairs,for10/100/1000 Base-TCCAFGB-G5021-A020-C0SF/UTP flex/26,gray,1xS1200/2 and1xRJ45 connector,2 pairs,for 10/100Base-TCCAFGD-D1024-A030-C1S1200 19“ Patch Panel,for max. 24 S1200Modules,with integrated cablestrain relief, 1 U,front panel ofhigh-grade steelCAXFSV-02400-C001SF/UTP flex/26, gray,Cat.7, 2xS1200/2connectors, 2 pairsCCAFGB-G1026-A020-C1The highest level of system performance up to 10GBase-T forthe complete link is achieved through the utilization ofhigh-quality Category 7 cables, connectors and patch cords.The resulting performance and future security guaranty themaximum level of investment protection for cabling.The FutureCom F system offers technical transmissionpossibilities similar to those of optical cabling systems andpermits multimedia applications, such as TV transmission. Inaddition, it enables the optimal utilization of cablingthrough the use of 2-pair patch cords (cable sharing).FutureCom F cabling conforms with the standards and isoutstandingly well suited for all recognized standardizedvoice and data transmission procedures. This applies to analogvoice transmission, ISDN, Token Ring, Ethernet (10-Base-T), Fast Ethernet (100Base-TX), Gigabit Ethernet, 10 GigabitEthernet, 100Base-VG and ATM.The performance of the FutureCom F cabling system hasbeen certified by an independent testing body (see certificate).Of course, all EMC values standardized in Europe areobserved.14 Corning Cable Systems


FutureCom F System Datafor Channel Class F (2002)Electrical Characteristics (at 20°C)Frequency in MHzMax. attenuation in dB*Attenuation in dB (typ. FutureCom F values)Min. NEXT in dB*NEXT in dB (typ. FutureCom F values)Min. ACR in dB*ACR in dB (typ. FutureCom F values)Min. ELFEXT in dB*ELFEXT in dB (typ. FutureCom F values)Min. return loss in dB*Return loss in dB (typ. FutureCom F values)* According to ISO/IEC 11801 (2002)14.01.965.0104.061.0102.165.0103.019.021.010–The system values cited only apply to the use of original FutureCom F products. Derived values, such as PSACR, PSNEXT,PSELFEXT, are in observance of the standard values, but are not shown.5.3–99.0–93.7–95.0–21.020–7.5–96.0–88.5–91.0–21.062.5–13.4–89.0–75.6–83.0–21.010020.817.162.986.042.168.944.479.012.021.0155.5–21.4–82.0–60.6–74.0–21.025033.827.556.978.023.150.537.868.08.019.060054.643.551.268.0–3.424.531.354.08.016.0850–52.3–60.0–7.7–45.0–15.01000–57.6–58.0–0.4–41.0–14.01200–69.2–53.0–––30.0–10.0FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionAttenuation andNear-end Crosstalk (NEXT)NEXT in dB(typ. FutureCom F values)min. NEXT in dBAccording to standardmax. Attenuation in dBAccording to standardAttenuation in dB(typ. FutureCom F values)FutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFrequency in MHzFlex Wire Cablefor Patch CordIndustrialCableFurther<strong>Information</strong>SpecialCableCorning Cable Systems15


FutureCom F System Datafor Channel Class F (2002)Far-end Crosstalk Relatingto the Far End (ELFEXT)ELFEXT in dB(typ. FutureCom F values)Min. ELFEXT in dBAccording to standardFrequency in MHzReturn LossReturn loss in dB(typ. FutureCom F values)min. Return loss in dBAccording to standardFrequency in MHzTest SetupFutureCom F F/STP flex/26 Test Adapter Cable, 2 mS1200 Module90 m FutureCom F/STP 1200/22S1200 Patch Panel 19“FutureCom F F/STP flex/26 Test Adapter Cable, 2 mNominal intrinsic impedanceMax. DC loop resistance (according to standard)DC loop resistance(typ. FutureCom F values)Max. delay (according to standard)Max. delay (according to standard)100 40 15 0.05 µs 0.02 µs16 Corning Cable Systems


FutureCom F CertificatesFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems17


FutureCom F Cat.7 + CablesS/FTP 1500/22 and S/FTP 1200/22Braided shieldHalogen-free sheath,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductorAWG 22ApplicationThe FutureCom S/FTP 1500/22 and S/FTP 1200/22 cablesare designed for applications up to 1500/1200 MHz. Theirtransmission characteristics significantly exceed the requirementsdefined by today’s Category 7 specifications(EN50288).FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for applications above 1 Gigabit Ethernet. The possibilityof using the cable up to the GHz area enables thehighest possible transmission rates for multimedia applicationssuch as TV transmission, in future-proof networks.Mechanical CharacteristicsConductor insulationHalogen-freeFoam-skin materialOuter jacketHalogen-free,flame retardantArea/range of applicationDry and damp roomsTemperature range (installation) 0 to +50°COperating temperature-20 to +60°CMin. bending radius>_ 45 mm (for 2x (4x2...)for one-time bendingover flat side)Min. bending radius during >_ 65 mm (for 2x (4x2...)installationover flat side)Copper conductorAWG 22Each pair is individually foil shielded (FTP). The strandedpairs (PiMF) are also sheathed with a braid shield (S/FTP),which guarantees outstanding shielding characteristics. Thecable satisfies Class B interference radiation standards(EN 55022), as well as immunity (EN 55024), which enablesthe realization of CE-compatible networks.FeaturesSpecified up to 1500 MHz / 1200 MHzOutstanding electrical characteristicsEach pair is shielded (PiMF)Full copper braid shieldStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH)Fire retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 6103418 Corning Cable Systems


FutureCom F Cat.7 + CablesS/FTP 1500/22 and S/FTP 1200/22Electrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 mUnbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocityat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew1%>5000 M x km125 +/– 20 %100 +/– 15 %100 +/– 18 %100 +/– 25 %46 dB at 64 kHz>40 dB at 1 MHz>20 dB at 100 MHz0.77 x c for S/FTP 12000.76 x c for S/FTP 15004.2 ns/m6 ns/100 mElectrical Characteristics (at 20°C) for S/FTP 1500/22Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.01.780.0>105.077.0102.080.096.077.093.0103.3105.75.380.0>105.077.0102.074.096.071.093.099.7167.26.880.0>105.077.0102.069.996.066.993.098.231.2510.19.780.0>105.077.0102.064.193.061.190.095.3Electrical Characteristics (at 20°C) for S/FTP 1200/22Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.01.680.0>105.077.0103.080.096.077.094.0103.3105.74.980.0>105.077.0103.074.096.071.094.0100.116 207.2 8.16.4 7.080.0 80.0>105.0 >105.077.0103.069.996.066.994.098.677.0103.068.093.065.094.098.062.514.513.875.1>105.072.5102.058.188.055.185.091.231.2510.19.080.0>105.077.0103.064.193.061.191.096.010018.517.572.4>105.069.4102.054.082.051.079.087.562.514.512.875.1>105.072.5103.058.188.055.186.092.230033.330.865.3103.062.3100.044.568.041.55.072.210018.516.572.4>105.0* Standard: Requirements for 100 m installed Category 7 cable for Class F cabling sections (complies with EN 50288-4-1 andIEC 61156-7)69.4103.054.082.051.080.088.560048.944.060.895.057.892.038.455.035.452.051.030033.328.965.3102.062.3100.044.570.041.568.073.11000–57.8–85.082.0–37.0–34.027.260048.947.160.895.057.893.038.455.035.453.053.31200–63.6–80.077.0–31.0–28.016.41000–54.5–85.083.0–40.0–38.030.51500–72.0–75.072.0–24.0–21.03.01200–59.8–80.078.0–35.0–33.020.2FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems19


FutureCom F Cat.7 + CablesS/FTP 1500/22 and S/FTP 1200/22<strong>Ordering</strong> <strong>Information</strong>Type designationCategory No. of PairsFire Load(MJ/m)Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)Length(m)Order NumberS/FTP 1500/22 4PS/FTP 1500/22 8PS/FTP 1200/22 4PS/FTP 1200/22 8P7+7+7+7+48480.671.340.671.34YesYesYesYes1793581793587.77.7x16.57.77.7x16.5661336613310005001000500CCXFCB-M0047-C001-L7CCXFCB-M0087-C001-L6CCXFCB-L0047-C001-L7CCXFCB-L0087-C001-L620 Corning Cable Systems


FutureCom FS1200 Modules and ConnectorsFeaturesCategory 7+ ModuleUp to 1200 MHz bandwith per pairDust protection flap to prevent exposure to contaminantsWide range of installation optionsFew individual componentsHigh-level component densityIndividual shielding of the modulesFutureCom F IntroductionFutureCom 10 TENIndividual components of the S1200 ModuleFutureCom ES1200 AdapterRemoving the module icon (black plastic clasp on the upperside of the S1200 Module) enables the S1200 module to beinserted into the module adapter. The S1200 adapter extendsthe application possibilities of the Cat. 7 module tomany components in the LANscape® product range, such as:Patch panelsFrame setsFloor box solutionsHardware FutureCom UD FutureCom UE FutureCom DS1200 Module with adapter for LANscape® interfaceS1200 Connector TypesFor the FutureCom F System, the following connector typesare offered:Telephone /ISDN ProductsFlex Wire Cablefor Patch CordS1200/4 shielded connector, 4-pair(for solid or stranded conductors)S1200/2 shielded connector, 2-pairS1200/1 shielded connector, 1-pairAll patch cords modes can be created using these connectors.IndustrialCableSpecialCableS1200 Connector TypesFurther<strong>Information</strong>Corning Cable Systems21


FutureCom FModules and Module AccessoriesFeaturesBandwidths up to 1200 MHz per pair of wiresQuick and easy to installIDC connection (IDC = Insulation Displacement Contacts)Universal usage (direct or with adapter) in manyLANscape® componentsNegligible effect from interference through the individualshielding of the modules<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXFSM-00100-C001 S1200 module, 1 x S1200, shielded, Cat. 7+, 1/1for installation in LANscape patch panels,outlets and floor box mounting platesS1200 Module AdapterUnits perOrder Number Description DeliveryCAXFSN-00110-C001 S1200 module adapter, for the installation 6/1of the S1200 modules in LANscape patch panels,outlets and floor box mounting platesBlank CoversUnits perOrder Number Description Delivery1 slot for installation inFutureCom F S1200 patch panels,outlets and floor box mounting plates(S1200 direct assembly without module adapters)CAXFSN-00101-C001 white, RAL 9010 10/1CAXFSN-00108-C001 black, RAL 9005 10/122 Corning Cable Systems


FutureCom FS1200 ConnectorsFeaturesBandwidths up to 1200 MHz per pairQuick and easy to installIDC connection (IDC = Insulation Displacement Contacts)High density, i.e. for each module the following connectorcombinations can be used:– one 4-pair connector– two 2-pair connectors– one 2-pair connector and two 1-pair connectors– four 1-pair connectorsShielded connectors are designed for the use with S/FTPtype cablesFutureCom F IntroductionFutureCom 10 TENFutureCom E<strong>Ordering</strong> <strong>Information</strong>S1200/4 Connector 4-pairs, shielded, Cat.7+Units perOrder Number Description DeliveryCAXFSS-00100-C001 S1200/4 Connector, shielded, Cat. 7+, 1/14-pair, for flex wire cables AWG 26Further<strong>Information</strong>FutureCom DFutureCom UEFutureCom UDTelephone /ISDN ProductsSpecialCableIndustrialCableFlex Wire Cablefor Patch CordHardwareCAXFSS-00100-C004 1200/4 Connector, shielded, Cat. 7+, 1/14-pair, for solid wire AWG 22 to 23,e.g. for consolidation point cablingCorning Cable Systems23


FutureCom FS1200 Connectors<strong>Ordering</strong> <strong>Information</strong>S1200/2 Connector, 2-pair, shielded, Cat. 7+Units perOrder Number Description DeliveryCAXFSS-00100-C002 S1200/2 Connector, shielded, Cat.7+, 1/12-pair, for flex wire cable AWG 26S1200/1 Connector, 1-pair, shielded, Cat. 7+CAXFSS-00100-C003 S1200/1 Connector, shielded, Cat.7+, 1/11-pair, for flex wire cable AWG 2624 Corning Cable Systems


FutureCom F ToolsFeatures of the S1200 Assembly ToolIntegrated knife for the removal of the jacketStripping option for the PiMF foils with a defined lengthManagement for arrangement or shaping of the individualpairs (PiMF)Defined section length of the wires<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXFSN-00000-C001 S1200 Tool, 1/1for the assemblyof S1200 modulesand S1200/4 orS1200/2 connectorsParralel Pliers and Copper Conducting TapeCAXCSN-00000-C008 Comfort Parallel Pliers, for the termination of 1/1the IDC contacts on FutureCom S1200 modulesFurther<strong>Information</strong>SpecialCableFlex Wire Cablefor Patch CordHardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionTelephone /ISDN ProductsCAXCSN-00000-C004 Copper Conducting Tape, 12.7 mm wide, 2/1roll length 16.5 mIndustrialCableCorning Cable Systems25


FutureCom FOutlets and Outlet AccessoriesFeatures of the Frame SetDirect installation of S1200 modulesCentral plate dimensions of 50 x 50 mm and can be combinedwith “DELTAprofil” and “DELTAfläche” face plates,as well as face plates from other manufacturersDesignation window<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXFSE-S0201-C001 S1200 Frame Set, inclined, 1/1for 2 FutureCom S1200 modules,including mounting frameand 50x50 mm central plate withdesignation window,threaded, white RAL 9010Features of the Frame SetsInstallation of S1200 modules with module adaptersCentral plate dimensions of 50 x 50 mm and can be combinedwith “DELTAprofil” and “DELTAfläche” face plates,as well as face plates from other manufacturersDesignation windowUnits perOrder Number Description DeliveryFrame Set, inclined, projecting,for 2 S1200 modules with moduleadapters, including mounting frameand 50x 50 mm central plate withdesignation windowand dust protection flapsWAXWSE-V0201-C001 white, RAL 9010 1/1WAXWSE-V0202-C001 pearl white, RAL 1013 1/1Labeling icons and designations labels can be found on page 131.Brackets for raceway mounting can be found on page 134.26 Corning Cable Systems


FutureCom FOutlets and Outlet AccessoriesFeatures of the Universal Integration HousingDirect assembly of S1200 modulesSurface mount housing suitable for the face plates; see page 136.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSE-V0201-C002 Universal Housing, inclined, projecting, 1/1for face plate (147x87 mm and 87x87 mm)for the direct integration of 2 S1200 modules,central partition provided, white, RAL 9010FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionWAXWSE-00001-C005 Face Plate, 87x87 mm, 1/1for one housing,including two metric screws andtwo withworth screws,for frame assembly in installation outlets,white, RAL 9010(Suitable Surface Mount HousingWAXWSE-00001-C004; see page 136)FutureCom UEFutureCom UDHardwareWAXWSE-00001-C007 Face Plate, 87x147 mm, 1/1for two housings,including two metric screwsand two withworth screws,for frame assembly in installation outlets,white, RAL 9010(Suitable Surface Mount HousingWAXWSE-00001-C006; see page 136)Further<strong>Information</strong>Telephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableCorning Cable Systems27


FutureCom FOutlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryFrame Set, inclined, for 3 S1200 moduleswith module adapters,including mounting frame and triple housingwith designation windowand dust protection flaps,also as 80x80 mm face plateWAXWSE-V0301-C001 white, RAL 9010 1/1WAXWSE-V0302-C001 pearl white, RAL 1013 1/1Frame Set, inclined, for 6 S1200 moduleswith module adapters,including mounting frameand two triple housingswith designation window anddust protection flaps,also as a 151x80 mm face plateWAXWSE-V0601-C001 white, RAL 9010 1/1WAXWSE-V0602-C001 pearl white, RAL 1013 1/1Installation OptionFrame Set, inclined, for 6 S1200 modules with moduleadapters, including mounting frame and two triple housingswith designation window and dust protection flaps, as wellas 151 x 80 mm face plate, white, RAL 9010:WAXWSE-V0601-C001Frame Set, inclined, projecting, for 6 modules,integrated into a racewayequipped with four S1200 modules with module adaptersCAXFSM-00100-C001 + CAXFSN-00110-C001one triple MT-RJ OM3 moduleLAXLSM-00212-C002two black labeling iconsWAXWSE-00008-C001two blue labeling iconsWAXWSE-00004-C001two green labeling iconsWAXWSE-00006-C001one black SF/UTP flex/26 Cat. 5 Patch CordCCAFGD-D6024-A020-C1and one blue S/FTP flex/26 Cat. 6 Patch CordCCAFGB-G2021-A030-C028 Corning Cable Systems


FutureCom FFloor Box SolutionsFeaturesSpecially designed for the direct integration of S1200modulesStable metal construction, no additional installationtrough requiredIntegrated cable strain relief that can be mountedin various positionsNo screwing requiredIntegrated grounding boltDesignation window with title strips<strong>Ordering</strong> <strong>Information</strong>FutureCom F IntroductionFutureCom 10 TENFutureCom EUnits perOrder Number Description DeliveryCAXFSU-00600-C001 Mounting Panel for Ackermann Floor Boxes 1/1GES 2, GES 4, GES 4/10, GESR 4, GES 6,GES 6/10, GESR 7/10 (outer) or GES 8/10,for the installationof 6 FutureCom F S1200 modules,with integrated cable strain reliefand six cable ties,designation window, blackFutureCom DFutureCom UEFutureCom UDCAXFSU-00900-C001 Mounting Panel for Ackermann Floor Boxes 1/1GESR 7/10 (center), GES 9 or GESR 9, forthe installationof 9 FutureCom F S1200 modules,with integrated cable strain reliefand nine cable ties,designation window, blackHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordCAXFSU-00900-C005 Mounting Panel for 1/1VanGeel Floor Box IK-1 (long),for the installationof 9 FutureCom F S1200 modules,with integrated cable strain reliefand nine cable ties,designation window, blackIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems29


FutureCom FFloor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXFSU-00900-C002 Mounting Panel for Kleinhuis Floor Box 1/1GR. II and GR. III (outside only),for the installationof 9 FutureCom F S1200 modules,with integrated cable strain reliefand nine cable ties,designation window, blackInstallation OptionMounting Panel for Kleinhuis Floor Boxes GR. II and GR. III(only left or right position):CAXFSU-00900-C002The three 3-port mounting places are configured as follows:equipped with two S1200 modules,CAXFSM-00100-C001one blank cover, white,CAXFSN-00101-C001and two gray 2-pairSF/UTP flex/26 10/100BaseT Patch CordsCCAFGD-D1024-A030-C1equipped with two S1200 modules,CAXFSM-00100-C001one blank cover, black,CAXFSN-00108-C001equipped with three S1200 modules,CAXFSM-00100-C001and one blue S/FTP flex/26 Cat. 6 Patch CordsCCAFGB-G2021-A030-C0For applications requiring fiber optic and copper solutions,the S1200 module can be integrated into the various floorbox mounting panels from the LANscape® product rangeusing an adapter (see pages 144-151).30 Corning Cable Systems


FutureCom FS1200 Patch PanelsFeaturesSpecially designed for the direct integration of S1200modulesIntegrated shielded transitional springPatch panel accessories, see page 156FutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXFSV-02400-C001 S1200 Patch Panel 19“, shielded, Cat. 7+, 1/1including 24 FutureCom F S1200 modules,with integrated cable strain relief and shieldedtransitional spring, 1 U, high-grade steelFutureCom 10 TENFutureCom EFutureCom DCAXFSV-02400-C002 S1200 Patch Panel 19“, 1/1for max. 24 FutureCom F S1200 modules,with integrated cable strain relief and shieldedtransitional spring, 1 U,high-grade steelFutureCom UEFutureCom UDHardwareCAXFSV-01200-C001 S1200 Patch Panel 10“, 1/1for max. 12 FutureCom F S1200 modules,with integrated cable strain relief and shieldedtransitional spring,1 U,high-grade steel front panelTelephone /ISDN ProductsFurther<strong>Information</strong>Flex Wire Cablefor Patch CordSpecialCableIndustrialCableCorning Cable Systems31


Consolidation Point Housingsfor S1200 ModulesFeaturesFull metal housing for the installation of up to12 FutureCom S1200 modulesStandard-compatible according to ISO/IEC 11801 (2002)and EN 50173-1 (2003)Easy installation for a distribution or consolidation pointConsolidation point housing is suitable for ceiling, wall,false floor or desk assemblyIndividual strain relief for the incoming and outgoingcable sectionsDust-proof feedthrough for incoming cableEasy plug-in of consolidation point cable (dust protectionand mechanical protection)Housing base electrically conductive for optimalshielding transition or groundingInstallation height of 60 mmHousing is fastened using special non-detachable screwsBlack sheet steel housing top, RAL 9005<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSW-00008-C014 Consolidation Point Housing for max. 12 FutureCom F S1200 modules, 1/1with strain relief for incoming data cables, patch cord strain relief anddust protection flap for floor, wall and ceiling installation,60 x 263 x 320 mm (HxWxD)32 Corning Cable Systems


FutureCom FCat. 7 Patch Cords S1200 to S1200DescriptionFutureCom F Category 7 patch cords are available in two orfour pair versions with foil and full braided shielding (S/FTP).They are pre-terminated with shielded S1200 connectors onboth ends and are available in various lengths. The patchcords meet all the transmision property requirements forChannel F (2002).FeaturesS/FTP flex cable, specified up to 600 MHzS1200/4 connector pair fully configured andapplication-neutralS1200/4 connector pair for up to 10GBase-T applicationsS1200/2 connector pair fully configured on both sidesMinimum surface transfer impedance(


FutureCom FCat. 6 Patch Cords S1200/4 to RJ45DescriptionApplication-neutral, Category 6 S/FTP patch cords with fourpairs are pre-terminated with S1200/4 and RJ45 connectors.The patch cords meet all the transmision propertyrequirements for Channel E (2002) and Cat. 6 (2002).FeaturesS/FTP flex cable, specified up to 600 MHzPre-terminated with S1200/4 on one end and RJ45 on theother endMinimum surface transfer impedance(


FutureCom FCat. 5 Patch Cords S1200/4 to RJ45DescriptionApplication-neutral, Category 5 SF/UTP patch cords with fourpairs are pre-terminated with S1200/4 and RJ45 connectors.The patch cords meet all the transmision property requirementsfor Channel D (2002) and Cat. 5 (2002).FutureCom F IntroductionFeaturesSF/UTP flex cable, specified up to 300 MHzPre-terminated with S1200/4 and RJ45 connectorsMinimum surface transfer impedance(


FutureCom FCat. 5 Patch Cords S1200/2 to RJ45DescriptionCategory 5 SF/UTP patch cords with two pairs arepre-terminated with S1200/2 and RJ45 connectors. The patchcords meet all the transmision property requirements forChannel D (2002) and Cat. 5 (2002).FeaturesSF/UTP flex cable, specified up to 300 MHzPre-terminated with S1200/2 and RJ45 connectorsMinimum surface transfer impedance(


FutureCom FU/UTP Flex Patch CordsDescriptionFutureCom F U/UTP flex FRNC patch cords are preterminatedwith S1200/1 or S1200/2 and RJ45 or RJ11/12connectors for service specific applications.FutureCom F IntroductionFeaturesU/UTP flex cable, specified up to 100 MHzPre-terminated with S1200/1 or S1200/2 connectorsPre-terminated with RJ11/12 or RJ45 connectorsMinimum surface transfer impedance(


FutureCom FTV Connecting CableFeaturesS1200/1 connector and balun (connector or jack) for theconversion of Cat.7+ cabling into coaxial cablingincl. impedance adjustmentVery low surface transfer impedance (


FutureCom FPlug & Play SolutionApplicationThe S1200 Solution Packages are factory pre-terminated cables. They are offered withFutureCom S/FTP 1200/22 cables, and enable Plug & Play installation, significantlyreducing installation time. The assemblies are 100% factory tested, preventing installationfaults on-site.<strong>Ordering</strong> <strong>Information</strong>S1200 Solution PackagesOrder Number Description LengthSolution Package with S/FTP 1200/22data cable, 4 pairs, application neutral,FRNC jacket, pre-terminatedwith 2 S1200 ModulesCCAFCB-M2042-A100-C0 S1200 Solution Package S/STP1200/22 - 10 10 mCCAFCB-M2042-A150-C0 S1200 Solution Package S/STP1200/22 - 15 15 mCCAFCB-M2042-A200-C0 S1200 Solution Package S/STP1200/22 - 20 20 mCCAFCB-M2042-A250-C0 S1200 Solution Package S/STP1200/22 - 25 25 mCCAFCB-M2042-A300-C0 S1200 Solution Package S/STP1200/22 - 30 30 mCCAFCB-M2042-A350-C0 S1200 Solution Package S/STP1200/22 - 35 35 mCCAFCB-M2042-A400-C0 S1200 Solution Package S/STP1200/22 - 40 40 mCCAFCB-M2042-A450-C0 S1200 Solution Package S/STP1200/22 - 45 45 mCCAFCB-M2042-A500-C0 S1200 Solution Package S/STP1200/22 - 50 50 mCCAFCB-M2042-A550-C0 S1200 Solution Package S/STP1200/22 - 55 55 mCCAFCB-M2042-A600-C0 S1200 Solution Package S/STP1200/22 - 60 60 mCCAFCB-M2042-A650-C0 S1200 Solution Package S/STP1200/22 - 65 65 mCCAFCB-M2042-A700-C0 S1200 Solution Package S/STP1200/22 - 70 70 mCCAFCB-M2042-A750-C0 S1200 Solution Package S/STP1200/22 - 75 75 mCCAFCB-M2042-A800-C0 S1200 Solution Package S/STP1200/22 - 80 80 mCCAFCB-M2042-A850-C0 S1200 Solution Package S/STP1200/22 - 85 85 mCCAFCB-M2042-A900-C0 S1200 Solution Package S/STP1200/22 - 90 90 mCCAFCB-M2042-A950-C0 S1200 Solution Package S/STP1200/22 - 95 95 mS1200 Consolidation Point Solution PackagesFutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordOrder Number Description LengthCP Solution Package S/FTP1200/22, 4 pairs,application-neutral, FRNC jacket,pre-terminated with one S1200/4connector and one S250 modulefor consolidation pointsCCAFCB-M2058-A050-C0 CP Solution Package S/STP1200/22 -5 5 mCCAFCB-M2058-A100-C0 CP Solution Package S/STP1200/22 -10 10 mCCAFCB-M2058-A150-C0 CP Solution Package S/STP1200/22 -15 15 mCCAFCB-M2058-A200-C0 CP Solution Package S/STP1200/22 -20 20 mIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems39


FutureCom FTest Adapter CablesApplicationsFor acceptance tests, special Test Adapter Cables are neededfor the Fluke DSP 4x00 and Microtest OMNIScanner/-OMNIScanner 2 testers in accordance with Class F (2002).A pair of these test adapter cables is always required to performthe test.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCCAFGB-G20ME-A020-C0 S1200 Test Adapter Cable, 2 m, 2/1for Fluke DSP 4x00 (per pair)CCAFGB-G20MM-A020-C0 S1200 Test Adapter Cable, 2 m, for Microtest 2/1OMNIScanner/OMNIScanner 2 (per pair)If you require test adapter cables for other testing equipment(e.g. LANTEK 7), please contact the relevantmanufacturer directly.40 Corning Cable Systems


Table of contents3 FutureCom 10 TEN System3.1. System Descriptions & Data 423.2. Certificate 453.3. Cable 463.4. Connecting Hardware3.4.1. S10 TEN Module Overview 473.4.2. S10 TEN Module 483.5. Hardware3.5.1. S10 TEN Outlets 493.5.2. S10 TEN Patch Panels 493.6. Patch Cords3.6.1. 10GBase-T Patch Cords 503.6.2. Consolidation Point Patch Cords 513.7. Plug & Play 523.8. Test Cable 54Further<strong>Information</strong>SpecialCableIndustrialCableFutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareCorning Cable Systems41


FutureCom 10 TEN SystemCorning Cable Systems’ FutureCom 10 TEN System has been especially developed to support 10 Gigabit Ethernet (10GBase-T)over 100 meters. FutureCom 10 TEN is the latest addition to Pretium Solutions, Corning Cable Systems’ high-performancefiber and copper solutions for premises networks, and is fully compliant with the IEEE 802.3an (Draft 2.0) standard for10 Gigabit Ethernet transmission. The current FutureCom 10 TEN is especially designed for 10 Gigabit applications in riser andhorizontal environments, avoiding alien near-end and far-end cross talk (ANEXT, AFEXT), in order to warrant the higherperformance of cabling through immunity.Face Plate“DELTAprofil”,80x80 mmWAXWSE-00001-C001and S10 TEN outlet,2xRJ45,10GBase-T, inclinedCAXTSD-S0201-C001FutureComS/FTP900/23CCXEDB-I0047-C001-L7S10 TEN Module,1 x RJ45,shielded,10GBase-TCAXTSM-00112-C001S/FTP flex/26,gray,2xRJ45- connectors,4 pairs, for up to10GBase-TCCATGB-G1002-A020-C0S/FTP flex/26,gray,2xRJ45 connectors,4 pairs, for up to10 GBase-TCCATGD-G1002-A020-C0S10 TEN Patch Panel 19“,for max. 24 S10 TENmodules,with integrated cablestrain relief, 1 U,front panel ofhigh-grade steelWAXTSV-02400-C001A very high level of system performance is achieved for thelink through the use of high-quality 10GBase-T connectiontechnology. The quality of the components guaranteesmaximum future security and reliability.Using all eight contacts in the RJ45 Connector as well as inthe RJ45 Module, the cabling can be used universally and isapplication-independent.It is suitable for all recognized standardized voice and datatransmission applications up to 10GBase-T.The performance of the FutureCom 10 TEN cabling system hasbeen certified by an independent testing body (see certificate).Of course, all standardized EMC threshold values inEurope are observed.42 Corning Cable Systems


FutureCom 10 TEN System Datafor Channel 10GBase-TElectrical Characteristics (at 20°C)Frequency in MHzMax. attenuation in dB according to standard *Attenuation in dB (typ. FutureCom 10 TEN values)Min. NEXT in dB according to standard *NEXT in dB (typ. FutureCom 10 TEN values)Min. ACR in dB according to standard *ACR in dB (typ. FutureCom 10 TEN values)Min. ELFEXT in dB* according to standard *ELFEXT in dB (typ. FutureCom 10 TEN values)Min. return loss in dB according to standard *Return loss in dB (typ. FutureCom 10 TEN values)* According to IEEE 802.3 an (draft 2.0).The system values cited only apply to the use of original FutureCom 10 TEN products. Derived values, such as PSACR, PSNEXT,PSELFEXT, are in observance of the standard values, but are not shown.14.02.065.089.461.088.163.380.419.033.910–5.6–85.3–78.5–61.9–32.720–8.0–75.0–66.6–56.4–30.762.5–14.3–63.6–49.5–52.9–32.410021.718.139.957.918.240.123.351.812.032.1155.5–22.7–53.3–31.3–44.3–31.3200–25.7–50.7–25.8–41.0–30.325035.928.833.147.9– 2.820.215.338.17.226.550053.441.922.037.6– 31.4-2.09.331.36.022.1FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionAttenuation andNear-end Crosstalk (NEXT)NEXT in dB(typ. FutureCom 10 TEN values)min. NEXT in dBAccording to Standardmax. Attenuation in dBAccording to StandardAttenuation in dB(typ. FutureCom 10 TEN values)Further<strong>Information</strong>FutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsIndustrialCableSpecialCableFlex Wire Cablefor Patch CordFrequency in MHzCorning Cable Systems43


SOUHRNNÁ TERITORIÁLNÍ INFORMACESrbsko8.2. Podmínky zaměstnávání cizinců a místních silCizinec může získat zaměstnání v Srbsku v případě, že: a) má povolení k trvalému či dočasnémupobytu; b) získá souhlas s uzavřením pracovního vztahu - pracovní povolení. Pracovní povolení nenípotřeba pokud cizinec splňuje podmínku a) a pracovní vztah je založen na dohodě o obchodně-technickéspolupráci, dlouhodobé výrobní spolupráci, o transferu technologií a o zahraniční investici. Zaměstnavatelje povinen Národní zaměstnanecké službě („Nacionalna služba za zapošljavanje" - NSZ) poskytnout údajeo počtu zaměstnávaných osob, kvalifikační struktuře a době trvání pracovního vztahu. NSZ vydá pracovnípovolení na žádost cizince, který disponuje povolením k trvalému pobytu a na žádost zaměstnavatele,který uzavírá pracovní smlouvu s cizincem, který má povolení k dočasnému pobytu.Příslušná pobočka NSZ může odmítnout vydat pracovní povolení a nabídnout některého evidovanéhouchazeče o práci v případě, že má v evidenci nezaměstnané, kteří splňují kvalifikační kritéria.V roce 2005 byl schválen nový zákoník práce, jehož přijetí vyvolalo vlnu nesouhlasu a vášnivýchreakcí, a to především ze strany odborářů. Podle nového zákona musí zaměstnavatel před udělenímvýpovědi zaměstnance písemně upozornit a ponechat mu pět dní na „obranu". Zaměstnanec máprávo na dovolenou ve výši nejméně 20 pracovních dní ročně. Práce v noci je možná pouze po získánísouhlasu ministerstev práce a zdravotnictví a odborů. Výpovědní lhůta při propuštění zaměstnance jetřicet dní, náhrada se určuje od jedné do čtyř mezd. Pracovník, který je označen za nadbytečného, máprávo na odstupné („otpremnina") ve výši třetiny průměrné mzdy za poslední tři měsíce vynásobenéodpracovanými roky.8.3. Podmínky pro zřízení kanceláře, reprezentace, společnéhopodnikuNejčastějšími právními subjekty, které v Srbsku vykonávají svoji činnost, jsou společnosti s ručenímomezeným („društvo s ograničenom odgovornošću - d.o.o.") a akciové společnosti („akcionarsko društvo- a.d."). Základní jmění společnosti s ručením omezeným nemůže být nižší než 500 EUR v dinárovémvyjádření podle aktuálně platného kursu. Ke dni zápisu do obchodního rejstříku musí být složeno nejméně50% základního jmění. Zbylá částka musí být uhrazena do dvou let po založení společnosti. Akciovéspolečnosti mají určené minimální základní jmění v dinárovém vyjádření ve výši 10.000 EUR (tzv.uzavřené akciové společnosti, které nemohou prodávat akcie na burze) a 25.000 EUR (otevřené akciovéspolečnosti) se stejnou povinností uhradit 50% jmění ke dni zápisu.Ve věstníku RS č. 55/2004 byl publikován zákon o registraci hospodářských subjektů (HS) a zákono založení Agentury pro hospodářské registry. Zákonem se zakládá Registr hospodářských subjektů(registr), který je jednotnou centrální, veřejnou a elektronickou bází informací o HS na území RS. Registrobsahuje jak základní údaje o HS (název, sídlo, datum založení, DIČ, předmět činnosti atd.), tak iúdaje o jménu a adrese zakladatele(-ů) a ředitele firmy. Pokud o to subjekt projeví zájem, může registrobsahovat i telefonní a faxové spojení, stejně jako e-mailovou a webovou adresu firmy.Zájemci mohou k registru přistupovat prostřednictvím Agentury pro HS či prostřednictvím internetu(náhled, předkládání registračních dokumentů a obdržení výpisů o HS). Na základě požadavku jeregistrátor povinen, prostřednictvím Agentury pro HS, vydat potvrzení o registrovaném údaji, kopiidokumentu, na jehož základě byla registrace provedena či potvrzení, že registr neobsahuje požadovanýúdaj, to vše do dvou dnů od doručení žádosti (prostřednictvím agentury, poštou či elektronickou cestou).Dokumenty k registraci se předkládají v srbštině. Pokud si zakladatel firmy přeje některé údajeregistrovat i v angličtině či některém z dalších oficiálních jazyků EU, je povinen s registrací předložit ipřeklad daných údajů (s ověřením tohoto překladu od soudního tlumočníka). Registrační dokumentymohou předložit: zakladatel(-é) podniku či osoba, zplnomocněná zastupovat HS. Totéž platí přidoplňování či změně údajů. Žádost o registraci se agentuře zasílá prostřednictvím internetu tak, žezakladatel společnosti na internetové stránce agentury vyplní formulář a dokumenty, které se přikládajík žádosti o registraci, doručí v elektronické podobě na elektronickou adresu agentury. Žadatel však musído pěti dnů od podání elektronické žádosti doručit originály daných dokumentů na adresu agentury, zaden doručení, od kterého se počítá lhůta pro vyřízení žádosti, je poté považován den doručení originálníchdokumentů. O přijetí žádosti agentura vydá potvrzení, které předkladateli zasílá na poštovní či e-mailovouadresu, uvedenou v textu žádosti. Agentura přezkoumá formální správnost uvedených údajů a pokud jsou46/55


FutureCom 10 TEN 10GBase-T CablesFeaturesBraided shieldHalogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductorAWG 23 - AWG 22Specified up to 1500 MHzOutstanding electrical characteristicsEach pair is shielded (PiMF)Full copper braid shieldStreamlined designLightweightLow signal skew between the pairsHalogen-free (LSZH)Fire retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034ApplicationThe cables for the FutureCom S10 TEN System are designedfor applications up to 1500 MHz (S/FTP 600 up to S/FTP 1500*).Their transmission characteristics significantly exceed therequirements defined by today’s Category 7 specifications(EN50288-4-1).FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for applications running 10 Gigabit Ethernet. Thepossibility of using the cable up to the GHz area enables thehighest possible transmission rates for multimedia applications,such as TV transmission, in future-proof networks.Each pair is individually foil shielded (FTP). The strandedpairs (PiMF) are also sheathed with a braid shield (S/FTP),which guarantees outstanding shielding characteristics. Thecable satisfies Class B interference radiation standards(EN 55022), as well as immunity (EN 55024), which enablesthe realization of CE-compatible networks.* For S/FTP 600 and 900 cable please see pages 61-63. ForS/FTP 1500 and 1200 cable please see pages 18-20.46 Corning Cable Systems


FutureCom S10 TENModule OverviewFeaturesFully compatible with all modular LANscape® systemesWide range of installation optionsFew individual componentsHigh-level component densityIndividual shieldingHalogen-freeFire class UL94V-0FutureCom F IntroductionFutureCom 10 TENIndividual Components of the S10 TEN ModuleFutureCom EFutureCom S10 TEN TechnologyOptimized construction with printed circuit board forbandwidths of more than 500 MHzMore than 1500 connector cycles are possibleProven IDC technology for wires with AWG 24 to AWG 22Module reusable several timesFutureCom DFutureCom UEFutureCom UDDisassembled S10 TEN ModuleHardwareApplicationWire management using TIA/EIA 568 A/B codingTransparent wire management allows direct control ofcorrect wiringInstallation in pairs (no untwisting of pairs is necessary)Rapid assembly timesEasy handlingCompatible with all FutureCom S/FTP cablesTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableS10 TEN Wire Management, without/with cableFurther<strong>Information</strong>Corning Cable Systems47


FutureCom 10 TENS10 TEN ModuleFeaturesEasy and quick to install, no special tools requiredIDC connection (IDC = Insulation Displacement Contacts)High-level component densityUniversal usage in all modular LANscape®and FutureCom components10GBase-T<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXTSM-00112-C001 S10 TEN Module, 1xRJ45, shielded, 1/110GBase-T, module aqua,with transparent TIA/EIA 568 A/Bwire management, incl. copperconducting tape for installationin LANscape modular patch panels,outlets and floor box solutionsCable Strain ReliefUsing the additional cable strain relief allows increased pulling forces on the module housings.Unit perOrder Number Description DeliveryCAXCSN-00000-C001 Additional cable strain relief, 100/1for fixing higher pulling forceson shielded FutureCom modulesfor solid wire, and for assembly offlexible consolidation point cableswith FutureCom S10 TEN fx , S250 fx andU250 fx modules48 Corning Cable Systems


FutureCom 10 TENS10 TEN Outlets and Patch Panels<strong>Ordering</strong> <strong>Information</strong>S10 TEN OutletsUnit perOrder Number Description DeliveryCAXTSD-S0201-C001 S10 TEN Outlet, 2xRJ45, 1/1shielded,10GBase-T,inclined, incl. mounting framewith grounding flaps,central plate 50x50 mmwith designation window, screw fixing,copper conducting tape(without faceplate),white, RAL 9010CAXTSD-S0202-C001 S10 TEN Outlet, 1/12xRJ45, shielded,10GBase-T,inclined, incl. mounting frame withgrounding flaps, central plate 50x50 mmwith designation window, screw fixing,copper conducting tape(without faceplate)pearl white, RAL 1013FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionS10 TEN Patch PanelHardwareUnit perOrder Number Description DeliveryCAXTSV-02400-C001 S10 TEN Patch Panel 19“, shielded, 1/110GBase-T, incl. 24 FutureCom S10 TENmodules and copper conducting tape,with integrated strain relief, 1 U,high-grade steel front panelIndustrialCableTelephone /ISDN ProductsFlex Wire Cablefor Patch CordWAXTSV-02400-C001 S10 TEN Patch Panel 19“, 1/1for up to 24 FutureCom S10 TENmodules, with integrated strainrelief, 1 U, high-grade steel front panelFurther<strong>Information</strong>SpecialCableCorning Cable Systems49


FutureCom 10 TENPatch Cords RJ45 to RJ45DescriptionThe FutureCom 10 TEN System patch cords consist of Category7 flexible cables with shielded RJ45 connectors at bothends. The flex cables have four individual foil-shielded pairsand full braid copper shielding.The zero halogen patch cords (LSZH) are non-corrosive(according to IEC 60754-2), low smoke (according to IEC61034) and flame retardant (according to IEC 60332-1).FutureCom 10 TEN patch cords provide additional latchprotection. They are available in various lengths and colors.FeaturesFlex cable specified up to 600 MHzMinimum surface transfer impedance(


FutureCom 10 TENConsolidation Point Patch CordsDescriptionThe FutureCom 10 TEN Consolidation Point Patch Cords areTEN fxfactory terminated cable assemblies with one S10module and one RJ45 connector. FutureCom S/FTP flex/26cable is specified up to 600 MHz and satisfies Category 7transmission characteristics. The CP Patch Cords are suitablefor connection from LANscape® Consolidation Point Housingsto wall or desktop outlets.Further<strong>Information</strong>FutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsSpecialCableIndustrialCableFlex Wire Cablefor Patch CordFutureCom EFutureCom F IntroductionFutureCom 10 TEN<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthS/FTP flex/26 Patch Cords, 4 pairsapplication-neutral, FRNC sheath,gray, pre-terminated with one RJ45connector and one S10 TEN fx module,for 10GBase-T applicationsCCATGB-F1062-A050-C0 CP Patch Cords S/FTP flex/26 - 5 5 mCCATGB-F1062-A100-C0 CP Patch Cords S/FTP flex/26 - 10 10 mCCATGB-F1062-A150-C0 CP Patch Cords S/FTP flex/26 - 15 15 mCCATGB-F1062-A200-C0 CP Patch Cords S/FTP flex/26 - 20 20 mOther lengths upon requestCorning Cable Systems51


FutureCom 10 TENPlug & Play SolutionsApplicationThe S10 TEN Solution Packages are pre-terminated cables withS10 TEN modules at both ends. They are generally offered withFutureCom S/FTP 900/23 cables. Both modules areequipped with additional cable strain relief to allow higherpulling force during installation (the pulling force is restrictedby the cable only). They enable Plug and Play installationand therefore significantly reduce installationtime. 100% factory testing reduces failures during installation.<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthS10 TEN Solution Package, withS/FTP 900/23 cable,4 pairs, FRNC jacket, pre-terminatedwith 2 S10 TEN modules,and additional cable strain reliefCCATDB-F2063-A100-C0 S10 TEN Solution Package S/FTP 900/23 - 10 10 mCCATDB-F2063-A150-C0 S10 TEN Solution Package S/FTP 900/23 - 15 15 mCCATDB-F2063-A200-C0 S10 TEN Solution Package S/FTP 900/23 - 20 20 mCCATDB-F2063-A250-C0 S10 TEN Solution Package S/FTP 900/23 - 25 25 mCCATDB-F2063-A300-C0 S10 TEN Solution Package S/FTP 900/23 - 30 30 mCCATDB-F2063-A350-C0 S10 TEN Solution Package S/FTP 900/23 - 35 35 mCCATDB-F2063-A400-C0 S10 TEN Solution Package S/FTP 900/23 - 40 40 mCCATDB-F2063-A450-C0 S10 TEN Solution Package S/FTP 900/23 - 45 45 mCCATDB-F2063-A500-C0 S10 TEN Solution Package S/FTP 900/23 - 50 50 mCCATDB-F2063-A550-C0 S10 TEN Solution Package S/FTP 900/23 - 55 55 mCCATDB-F2063-A600-C0 S10 TEN Solution Package S/FTP 900/23 - 60 60 mCCATDB-F2063-A650-C0 S10 TEN Solution Package S/FTP 900/23 - 65 65 mCCATDB-F2063-A700-C0 S10 TEN Solution Package S/FTP 900/23 - 70 70 mCCATDB-F2063-A750-C0 S10 TEN Solution Package S/FTP 900/23 - 75 75 mCCATDB-F2063-A800-C0 S10 TEN Solution Package S/FTP 900/23 - 80 80 mCCATDB-F2063-A850-C0 S10 TEN Solution Package S/FTP 900/23 - 85 85 mCCATDB-F2063-A900-C0 S10 TEN Solution Package S/FTP 900/23 - 90 90 m52 Corning Cable Systems


FutureCom 10 TENPlug & Play SolutionsApplicationThe S10 TEN Plug and Play Solution has been especially createdfor use in data center applications. This specialassembly consists of six S/FTP 900/23 cables, with a commonFRNC jacket. The cable is pre-terminated with six S10 TENmodules at both ends. All modules are equipped with additionalcable strain relief, to allow higher pulling force duringinstallation (the pulling force is restricted by the cable only).They enable rapid Plug and Play installation in data centersand therefore significantly reduce installation time. 100%factory testing reduces failures during installation.FutureCom F IntroductionFutureCom 10 TENFutureCom E<strong>Ordering</strong> <strong>Information</strong>FutureCom DOrder Number Description LengthS10 TEN Plug & Play Solution Package, with6x S/FTP 900/23 cables with commonFRNC jacket, both ends terminatedwith 6 S10 TEN modules,and additional cable strain reliefCCATDB-F2663-A200-C0 S10 TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 20 20 mCCATDB-F2663-A300-C0 S10 TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 30 30 mCCATDB-F2663-A400-C0 S10 TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 40 40 m*Other lengths available upon request.Installation OptionFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsS10 TEN Plug & Play Solution Package, with 6x S/FTP 900/23cables with common FRNC jacket, both ends terminatedwith 6 S10 TEN modules, and additional cable strain relief:CCATDB-F2663-A200-C0installed in a CCHE Empty Panel for 6 LANscape modulesCCHE-CP00-LSFlex Wire Cablefor Patch CordIndustrialCableSpecialCableCCHE Panel with Plug & Play Solution PackageFurther<strong>Information</strong>Corning Cable Systems53


FutureCom 10 TENUniversal Test Cord for Channel TestingApplicationThe universal channel test cord can be used for acceptancetests of shielded FutureCom 10 TEN system in conjunction withthe universal test adapter from Fluke or other test devicemanufactureres.One pair of these test cords is required for acceptance tests.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCCATGB-F10M0-A030-C0 Universal Test Cord for the acceptance tests 1/1of the FutureCom 10 TEN system in conjunctionwith the universal test adapter from Flukeor another test device manufacturers,2xRJ45, 4 pairs, 3 m54 Corning Cable Systems


Table of contents4 FutureCom E4.1. System Descriptions & Data 564.2. Cable4.2.1. Cat. 7 S/FTP 900/23 and S/FTP 600/23 Cable 614.2.2. Cat. 6 S/FTP 450/23 Cable 644.2.3. Cat. 6 F/FTP 450/23 Cable 664.3. Connecting Hardware4.3.1. S250 Module Overview 684.3.2. Certificate for S250 Module 694.3.3. S250 Module 704.3.4. S250 fx Module 714.4. Hardware4.4.1. S250 Outlets and Patch Panel 724.4.2. S250 Double Module Outlet 734.4.3. Installation Options for Outlets 744.5. Patch Cords4.5.1. Cat.6 Patch Cords 754.5.2. Consolidation Point Patch Cords 764.6. Plug & Play 774.7. Test Cable 79FutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordFutureCom F IntroductionCorning Cable Systems55


FutureCom E SystemFutureCom E is Corning’s proven system solution for symmetrical cabling. It exceeds all requirements of the current ISO/IEC11801 (2002) and EN 50173-1 (2003) standards, Class D and E links and Categories 5 and 6 for components. In addition, theFutureCom E system also satisfies Category 5e according to TIA/EIA-568-A-5.Face Plate“DELTAprofil”,80x80 mmWAXWSE-00001-C001and S250 outlet,2xRJ45,Cat.6, inclined,CAXESD-S0201-C001FutureComS/FTP 600/23CCXEDB-F0047-C001-L7S250 Module,1 x RJ45,shielded, Cat. 6CAXESM-00100-C001S/FTP flex/26, blue,2xRJ45- connectors,4 pairs,for10/100/1000 Base-TCCAEGB-G2002-A020-C0S/FTP flex/26, blue,2xRJ45 connectors,4 pairs,for 10/100/1000Base-TCCAEGB-G2002-A020-C019“ Patch Panel,formax. 24 LANscape®modules,with integrated cablestrain relief, 1 U,front panel ofhigh-grade steelWAXWSV-02400-C001A very high level of system performance is achieved for thelink through the use of high-quality Category 6 connectiontechnology, Category 6 and 7 cables and Category 6 patchcords. The resulting performance and the future securityguaranty maximum investment protection.The system is suitable for all recognized standardized voiceand data transmission procedures. This applies to analogvoice transmission, ISDN,Token Ring, Ethernet (10/100Base-T),Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T)and for future high bit-rate transmission procedures.Fully configured with a RJ45 connector and RJ45 module, thecabling can be used universally and is application-neutral.The performance of the FutureCom E cabling system hasbeen certified by an independent testing body (see certificate).Of course, all standardized EMC threshold values inEurope are observed.56 Corning Cable Systems


FutureCom E System Datafor Channel Class E (2002)Frequency in MHzMax. attenuation in dB*Attenuation in dB (typ. FutureCom E values)Min. NEXT in dB*NEXT in dB (typ. FutureCom E values)Min. ACR in dB*ACR in dB (typ. FutureCom E values)Min. ELFEXT in dB*ELFEXT in dB (typ. FutureCom E values)Min. return loss in dB*Return loss in dB (typ. FutureCom E values)* According to ISO/IEC 11801 (2002)The system values cited only apply to the use of original FutureCom E products. Derived values, such as PSACR, PSNEXT,PSELFEXT, are in observance of the standard values, but are not shown.14.02.165.072.261.070.663.37319.022.010–5.5–63.0–58.5–65.0–22.020–8.0–58.3–50.3–60.0–22.062.5–12.5–50.0–37.5–48.0–20.010021.716.539.946.618.230.023.346.012.018.0155.5–20.0–43.7–23.7–38.8–17.0200–24.0Attenuation andNear-end Crosstalk (NEXT)–41.1–17.1–35.0–16.025035.927.033.138.8– 2.811.815.333.38.015.0NEXT in dB(typ. FutureCom E values)min. NEXT in dBAccording to standardmax. Attenuation in dBAccording to standardAttenuation in dB(typ. FutureCom E values)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFrequency in MHzFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableCorning Cable Systems57


FutureCom E System DataFar-end Crosstalk Relatingto the Far End (ELFEXT)ELFEXT in dB(typ. FutureCom E values)Min. ELFEXT in dBAccording to standardFrequency in MHzReturn LossReturn loss in dB(typ. FutureCom E values)min. Return loss in dBAccording to standardFrequency in MHzTest SetupFutureCom E Test Cable, 2xRJ45, 3 mS250 Module, 2xRJ4590 m FutureCom S/FTP900/23S250 Patch Panel 19“FutureCom E Test Cable, 2 x RJ45, 3 mNominal intrinsic impedanceMax. DC loop resistance (according to standard)DC loop resistance (typ. FutureCom E values)Max. delay (according to standard)Max. delay (typ. FutureCom E values)100 40 18 0.05 µs 0.02 µs58 Corning Cable Systems


FutureCom E Certificate4-Connector ChannelFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems59


FutureCom E Certificate3-Connector Permanent Link60 Corning Cable Systems


FutureCom E Cat. 7+ and Cat.7 CablesS/FTP 900/23 and S/FTP 600/23Further<strong>Information</strong>FutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionBraided shieldHalogen-free jacket,flame retardantTwisted pairApplicationThe FutureCom S/FTP 900/23 and S/FTP 600/23 cables aredesigned for applications up to 1000/800 MHz and theirtransmission characteristics exceed Category 7 specifications.FutureCom UEFutureCom UDFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductorAWG 23FutureCom cables are low-skew products. This is increasinglyrequired for applications above 1 Gigabit-Ethernet. Thesuitability of the cable for utilization up to the GHz areaenables the highest possible transmission speeds in futureproofnetworks. These cables have a streamlined constructionand low weight.Each pair is individually shielded (PiMF). The stranded pairsare additionally braid shielded (S/FTP) which guaranteesoutstanding shielding characteristics. The cable satisfiesClass B interference radiation standards (EN 55022) as wellas immunity (EN 55024) which enables the realization ofCE-compatible networks.HardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableThe FutureCom S/FTP 900/23 and 600/23 cables are alsoavailable in a triplex version. The compact constructionallows flat as well as folded installation.SpecialCableCorning Cable Systems61


FutureCom E Cat. 7+ and Cat.7 CablesS/FTP 900/23 and S/FTP 600/23FeaturesS/FTP 900/23 specified up to 1000 MHz,S/FTP 600/23 specified up to 800 MHzOutstanding electrical characteristicsEasy and convenient installation on double and tripleoutletsCompact installation of the triple cable either flat orfolded (øonly 16.3 mm)Each pair is individually foil shieldedFull braid shieldLow skew between the pairsHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034Mechanical CharacteristicsElectrical Characteristics (at 20°C)Conductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-freeFoam-skin materialHalogen-free,flame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 40 mm (for 2 or 3x(4x2...) over flat side)>_ 60 mm (for 2 or 3x(4x2...) over flat side)AWG 23Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 mUnbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocityat > 10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew1%>5000 m x km125 +/– 20%100 +/– 15%100 +/– 18%100 +/– 25%46 dB at 64 kHz>40 dB at 1 MHz>20 dB at 100 MHz0.79 x c4.2 ns/m4 ns/100 m62 Corning Cable Systems


FutureCom E Cat. 7+ and Cat.7 CablesS/FTP 900/23 and S/FTP 600/23Electrical Characteristics (at 20°C) for S/FTP 900/23Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100m12.01.780.0>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.077.098.080.093.077.091.0105.75.080.077.098.074.093.071.091.0167.26.580.077.098.069.993.066.991.0ACR in dB98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 31.0 24.0* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)Electrical Characteristics (at 20°C) for S/FTP 600/23Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB<strong>Ordering</strong> <strong>Information</strong>Type designationCategory No. of Pairs12.01.780.0Fire Load(MJ/m)208.17.380.077.098.068.093.065.091.031.2510.19.280.077.098.064.190.061.188.062.514.513.275.172.598.058.186.055.184.010018.516.872.469.498.054.083.051.081.0Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)30033.330.065.362.394.044.568.041.566.0>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.077.098.080.093.077.091.098.3105.75.080.077.098.074.093.071.091.095.0* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)167.26.580.077.098.069.993.066.991.093.5208.17.380.077.098.068.093.065.091.092.731.2510.19.280.077.098.064.190.061.188.090.862.514.513.275.172.598.058.186.055.184.086.810018.516.872.469.497.054.083.051.081.082.1Length(m)60048.942.560.892.057.890.038.451.035.449.030033.330.765.395.062.393.044.568.041.566.064.3900–55.0–86.0–84.0––––60048.944.060.891.057.889.038.451.035.449.047.0Order Number1000–59.0–83.0–81.0––––800–53.0–87.0–85.0––––34.0FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordS/FTP 900/23 4PS/FTP 900/23 4PS/FTP 900/23 8P7+7+7+4480.630.631.26YesYesYes1541543087.77.77.7x16.56464130S/FTP 900/23 12P 7+ 12 1.89 Yes 462 7.7x25.0 195S/FTP 600/23 4PS/FTP 600/23 4PS/FTP 600/23 8P7774480.630.631.26YesYesYes1541543087.77.77.7x16.56464130S/FTP 600/23 12P 7 12 1.89 Yes 462 7.7x25.0 195* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.10002505005001000250500500CCXEDB-I0047-C001-L7CCXEDB-I0047-C001-X2*CCXEDB-I0087-C001-L6CCXEDB-I0127-C001-L6CCXEDB-F0047-C001-L7CCXEDB-F0047-C001-X2*CCXEDB-F0087-C001-L6CCXEDB-F0127-C001-L6IndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems63


FutureCom E Cat. 6 CablesS/FTP 450/23Braided shieldHalogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductorAWG 23ApplicationThe FutureCom S/FTP 450/23 cables are designed forapplications of up to 600 MHz and their transmissioncharacteristics exceed Category 6 specifications.FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs are very low. This is increasinglyrequired for Gigabit-Ethernet. These cables have astreamlined construction and low weight.Each pair is individually shielded (PiMF). The stranded pairsare additionally braid shielded (S/FTP), which guaranteesoutstanding shielding characteristics. The cables satisfiesClass B interference radiation standards (EN 55022), as wellas immunity (EN 55024), which enables the realization ofCE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-freeFoam-skin materialHalogen-free,flame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 40 mm (for 2 x(4x2...) over flat side)>_ 60 mm (for 2 x(4x2...) over flat side)AWG 23S/FTP 450/23, specified up to 600 MHzOutstanding electrical characteristicsEach pair is shielded (PiMF)Full braid shieldStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 6103464 Corning Cable Systems


FutureCom E Cat. 6 CablesS/FTP 450/23Electrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 mUnbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocity at > 10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew1%>5000 M x km125 +/– 20%100 +/– 15%100 +/– 18%46 dB at 64 kHz>40 dB at 1 MHz>20 dB at 100 MHz0.79 x c4.2 ns/m4 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom EElectrical Characteristics (at 20°C)FutureCom DFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.11.866.0>100.0 >100.0 >100.0 >100.0 >100.0 97.064.098.066.093.064.091.098.2106.05.359.357.398.05093.04791.094.7* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)<strong>Ordering</strong> <strong>Information</strong>Type designationCategory No. of PairsFire Load(MJ/m)167.66.856.254.298.045.993.041.091.093.2208.57.654.852.898.044.093.041.091.092.431.2510.89.651.949.998.040.190.037.188.090.462.515.513.647.445.495.034.186.031.184.083.4Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)10019.917.344.395.042.393.030.083.027.081.077.7Length(m)25033.027.738.390.036.388.022.070.019.068.062.3450–38.0–85.0–83.0–54.0–52.047.0Order Number600–44.8–75.0–73.0–48.0–46.030.2FutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordFlex Wire Cablefor Patch CordIndustrialCableS/FTP 450/23 4PS/FTP 450/23 4PS/FTP 450/23 8P6664480.570.571.14YesYesYes1451452907.9 557.9 557.5x16.6 1201000250500CCXEDB-D0047-C001-L7CCXEDB-D0047-C001-X2*CCXEDB-D0087-C001-L6SpecialCable* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.Further<strong>Information</strong>Corning Cable Systems65


FutureCom E Cat. 6 CablesF/FTP 450/23ApplicationFoil shield (FTP)Halogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsAdditional wirePE foam-skin insulationCopper conductorAWG 23The FutureCom F/FTP 450/23 cables are designed forapplications of up to 450 MHz and their transmissioncharacteristics exceed Category 6 specifications.FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs are very low. This is increasinglyrequired for Gigabit-Ethernet. These cables have astreamlined construction and low weight.Each pair is individually shielded (PiMF). The stranded pairsare additionally foil shielded (F/FTP), which guarantees outstandingshielding characteristics. The cables satisfies ClassB interference radiation standards (EN 55022), as well as immunity(EN 55024), which enables the realization of CE-compatiblenetworks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-freeFoam-skin materialHalogen-free,flame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 40 mm (for 2 x(4x2...) over flat side)>_ 60 mm (for 2 x(4x2...) over flat side)AWG 23F/FTP flex cable, specified up to 450 MHzOutstanding electrical characteristicsEach pair is shielded (PiMF)Full foil shielding and additional copper wireStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH)Fire retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 6103466 Corning Cable Systems


FutureCom E Cat. 6 CablesF/FTP 450/23Electrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 mUnbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocity at >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew2%>5000 M x km125 +/– 20%100 +/– 15%100 +/– 18%100 m/m at 10 MHz>46 dB at 64 kHz>40 dB at 1 MHz>20 dB at 100 MHz0.79 x c4.3 ns/m4 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom EElectrical Characteristics (at 20°C)FutureCom DFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.11.866.0>100.064.098.066.093.064.091.098.2106.05.359.3>100.057.398.05093.04791.094.7167.66.856.2>100.054.298.045.993.041.091.093.2208.57.654.8>100.052.898.044.093.041.091.092.431.2510.89.651.9>100.049.998.040.190.037.188.090.462.515.513.647.497.045.495.034.186.031.184.083.410019.917.344.395.042.393.030.083.027.081.077.725033.027.738.390.036.388.022.070.019.068.062.3450–38.0–85.0–83.0–54.0–52.047.0* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)FutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Type designationCategory No. of PairsFire Load(MJ/m)Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)Length(m)Order NumberFlex Wire Cablefor Patch CordIndustrialCableF/FTP 450/23 4PF/FTP 450/23 4PF/FTP 450/23 8P6664480.570.571.16YesYesYes1051052107.47.47.4x15.550501001000250500CCXDDA-D0047-C001-L7CCXDDA-D0047-C001-X2*CCXDDA-D0087-C001-L6SpecialCable* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.Further<strong>Information</strong>Corning Cable Systems67


FutureCom EModule OverviewFeaturesFully compatible with all modular LANscape® systemsWide range of installation optionsFew individual componentsHigh-level component densityIndividual shieldingHalogen-freeFire class UL94V-0Optimized construction with printed circuit board forbandwidths of more than 300 MHz1500 connector cycles are possibleProven IDC technology for wires with AWG 24 to AWG 22Module reusable several timesIndividual Components of the S250 ModuleDisassembled S250 Basic ModuleFeaturesWire management using TIA/EIA 568 A/B codingInstallation in pairs(no untwisting of the pairs necessary)Rapid assembly timeEasy handlingCompatible with all FutureCom S/FTP and F/FTP cablesWire Management68 Corning Cable Systems


FutureCom E CertificateCat.6 De-embedded for S250 ModulesFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems69


FutureCom ES250 ModuleFeaturesEasy and quick to install, no special tools requiredIDC connection (IDC = Insulation Displacement Contacts)High-level component densityUniversal usage in all modular LANscape® andFutureCom componentsCategory 6 (2002), de-embedded<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXESM-00100-C001 S250 Module, 1xRJ45, shielded, Cat.6, 1/1incl. copper conducting tape for installationin LANscape modular patch panels,outlets and floor box solutionsCAXESM-00200-C001 S250 Double Module, 2xRJ45, shielded, Cat.6, 1/1incl. copper conducting tape for installationin LANscape modular patch panels,outlets and floor box solutionsCable Strain ReliefUsing the additional cable strain relief allows increased pulling force on the module housings.Unit perOrder Number Description DeliveryCAXCSN-00000-C001 Additional cable strain relief, 100/1for higher pulling force on shieldedFutureCom modules for solid wire,and for assembly of flexible consolidationpoint cables with FutureCom S10 TEN fx ,S250 fx or U250 fx modules70 Corning Cable Systems


FutureCom ES250 fx ModuleApplicationS250 fx Modules are used for the assembly of flexible cablesor consolidation point cables.FeaturesFully compatible with all modular LANscape® connectinghardwareWide range of installation optionsIndividual shieldingProven IDC technology for AWG 24 and AWG 26 strandedwiresModule reusable several times1500 connector cycles are possibleWire management using A/B printing according toTIA/EIA 568Installation in pairs (no untwisting of the pairs isnecessary)Easy handling and very short assembly timeCategory 6, de-embeddedIndividual components of the S250 fx ModuleFutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>Assembled S250 fx Modulewith Additional Cable Strain ReliefRequirements for Consolidation PointsFor the assembly of modules with flexible cables,an additional cable strain relief must be usedCCS patch cords (with RJ45 connectors) are wiredaccording to TIA/EIA 568 B; when using other singleendedpre-terminated connecting cables they should bewired according to the RJ45 connector schemeThe installed solid wire cable should have a lowerattenuation specification than the flexible cableFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordUnit perOrder Number Description DeliveryCAXESM-00100-C003 S250 fx Module, 1xRJ45, shielded, Cat.6, 1/1especially suitable for consolidation pointcable with AWG 24/26 stranded wires,incl. copper conducting tape andadditional cable strain relief for installation inLANscape hardwareIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems71


FutureCom ES250 Outlets and Patch Panel<strong>Ordering</strong> <strong>Information</strong>S250 OutletsUnit perOrder Number Description DeliveryS250 Outlet, 2xRJ45,shielded, Cat. 6, inclined,incl. mounting framewith grounding flaps,central plate 50x50 mmwith designation window,screw-fixed, copperconducting tape(without face plate)CAXESD-S0201-C001 white, RAL 9010 1/1CAXESD-S0202-C001 pearl white, RAL 1013 1/1S250 Patch PanelUnit perOrder Number Description DeliveryCAXESV-02400-C001 S250 Patch Panel 19“, 1/1shielded, Cat. 6, including24 FutureCom S250modules and copperconducting tape,with integratedcable strain relief,1 U, high-grade steelfront panelPatch panel accessories please see page 156.72 Corning Cable Systems


FutureCom ES250 Double Module Outlet<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXESD-S0200-C001 S250 Double Module Outlet, 1/12xRJ45, Cat. 6, inclined,incl. mounting frame withgrounding flaps andcopper conducting tape(suitable for Rutenbeckcompatiblecentral platesor faceplates)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom UDHardwareTelephone /ISDN ProductsFurther<strong>Information</strong>IndustrialCableSpecialCableFlex Wire Cablefor Patch CordFutureCom UEFutureCom DInstallation OptionS250 Double Module Outlet, 2xRJ45, Cat. 6, inclined,incl. mounting frame and copper conducting tape.CAXESD-S0200-C001For example, mounted with a high grade steel face platefrom JungS250 Double Module Outlet with face plate (Jung)Corning Cable Systems73


FutureCom EOutlet Installation OptionsOption 1: 6-Port Frame Set for the installation of 6LANscape® fiber optic or FutureCom modules, inclined, includingmounting frame and two triple housings with designationwindow and dust protection flaps as well as 151x80mm face plate, white, RAL 9010:WAXWSE-V0601-C001equipped with two S250 modulesCAXESM-00100-C001two black labeling iconsWAXWSE-00008-C001four blue labeling iconsWAXWSE-00004-C001and two blue S/FTP flex/26 Patch CordsCCAEGB-D2002-A030-C06-Port Frame Set, inclinedOption 2: S250 Inclined Outlet with two S250 Modules,white, RAL 9010 in the race-way:CAXESD-S0201-C001equipped with one black labeling iconWAXWSE-00008-C001and one blue labeling iconWAXWSE-00004-C001Built into a Tehalit race-wayS250 Inclined Outlet with two S250 ModulesOption 3: Double Surface Outlet for the mounting of 2 LANscapemodules, inclined, including face plate and doublehousing with designation window and dust protectionflaps, white, RAL 9010:WAXWSE-V0201-C001equipped with two S250 modulesCAXESM-00100-C001one gray labeling iconWAXWSE-00003-C001one green labeling iconWAXWSE-00006-C001and one green S/FTP flex/26 Patch CordCCAEGB-D4002-A020-C0using one surface mount housingWAXWSE-00001-C003... and one “DELTAfläche” face plate2-Port Surface Mount Outlet74 Corning Cable Systems


FutureCom ECat. 6 Patch Cords RJ45 to RJ45DescriptionThe FutureCom E System patch cords consist of Category 6flex cable with shielded RJ45 connectors at both ends. Theflex cables have four individual foil-shielded pairs and fullbraid copper shielding. The zero halogen patch cords (LSZH)are non-corrosive (according to IEC 60754-2), low smoke(according to IEC 61034) and flame retardant (according toIEC 60332-1, Category B). They are available in variouslengths and colors.FutureCom F IntroductionFutureCom 10 TENFeaturesFutureCom ES/FTP flex cable, specified up to 600 MHzApplication-neutral due to using all four pairsMinimum surface transfer impedance(


FutureCom EConsolidation Point Patch CordsDescriptionThe FutureCom E Consolidation Point Patch Cords arefactory terminated cable assemblies with one S250 fxmodule and one RJ45 connector. FutureCom S/FTP flex/26Cable is specified up to 600 MHz and satisfies Category 7transmission characteristics. The CP Patch Cords are suitableto connect LANscape® Consolidation Point Housings to wallor desktop outlets.<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthS/FTP flex/26 Patch Cords,4 pairs, application-neutral, FRNC sheath,gray, pre-terminated with one RJ45connector and one S250 fx module, Cat. 6,for example 10/100/1000Base-TCCAEGB-D1052-A050-C0 CP Patch Cords S/FTP flex/26 - 5 5 mCCAEGB-D1052-A100-C0 CP Patch Cords S/FTP flex/26 - 10 10 mCCAEGB-D1052-A150-C0 CP Patch Cords S/FTP flex/26 - 15 15 mCCAEGB-D1052-A200-C0 CP Patch Cords S/FTP flex/26 - 20 20 mOther lengths upon request76 Corning Cable Systems


FutureCom EPlug & Play SolutionsApplicationThe S250 Solution Packages are pre-terminated cables withS250 modules at both ends. They are generally offered withFutureCom S/FTP 900/23 cables. Both modules areequipped with additional cable strain relief, to allow higherpulling forces during insertion (the pulling force is restrictedby the cable only). They enable Plug and Play installationand therefore significantly reduce installation time.FutureCom F IntroductionFutureCom 10 TENFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>FutureCom DFutureCom E<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthSolution Package, S/FTP900/23 cable,4 pairs, FRNC jacket pre-terminatedwith 2 S250 modulesand additional cable strain reliefCCAEDB-D2050-A100-C0 S250 Solution Package S/FTP 900/23 - 10 10 mCCAEDB-D2050-A150-C0 S250 Solution Package S/FTP 900/23 - 15 15 mCCAEDB-D2050-A200-C0 S250 Solution Package S/FTP 900/23 - 20 20 mCCAEDB-D2050-A250-C0 S250 Solution Package S/FTP 900/23 - 25 25 mCCAEDB-D2050-A300-C0 S250 Solution Package S/FTP 900/23 - 30 30 mCCAEDB-D2050-A350-C0 S250 Solution Package S/FTP 900/23 - 35 35 mCCAEDB-D2050-A400-C0 S250 Solution Package S/FTP 900/23 - 40 40 mCCAEDB-D2050-A450-C0 S250 Solution Package S/FTP 900/23 - 45 45 mCCAEDB-D2050-A500-C0 S250 Solution Package S/FTP 900/23 - 50 50 mCCAEDB-D2050-A550-C0 S250 Solution Package S/FTP 900/23 - 55 55 mCCAEDB-D2050-A600-C0 S250 Solution Package S/FTP 900/23 - 60 60 mCCAEDB-D2050-A650-C0 S250 Solution Package S/FTP 900/23 - 65 65 mCCAEDB-D2050-A700-C0 S250 Solution Package S/FTP 900/23 - 70 70 mCCAEDB-D2050-A750-C0 S250 Solution Package S/FTP 900/23 - 75 75 mCCAEDB-D2050-A800-C0 S250 Solution Package S/FTP 900/23 - 80 80 mCCAEDB-D2050-A850-C0 S250 Solution Package S/FTP 900/23 - 85 85 mCCAEDB-D2050-A900-C0 S250 Solution Package S/FTP 900/23 - 90 90 mCorning Cable Systems77


FutureCom EPlug & Play SolutionsApplicationThe S250 Plug and Play Solution has been especially createdfor use in data center applications. This specialassembly consists of six S/FTP 900/23 cables, with a commonFRNC jacket. The cable is pre-terminated with six S250modules at both ends. All modules are equipped with additionalcable strain relief, to allow higher pulling force duringinstallation (the pulling force is restricted by the cable only).They enable rapid Plug and Play installation in data centersand therefore significantly reduce installation time. 100%factory testing reduces failures during installation.<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthS250 Plug & Play Solution Package, with6x S/FTP 900/23 cables with commonFRNC jacket, both ends terminatedwith 6 S250 modules,and additional cable strain reliefCCAEDB-D2650-A200-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 20 20 mCCAEDB-D2650-A300-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 30 30 mCCAEDB-D2650-A400-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 40 40 mOther lengths available upon request.Installation OptionS250 Plug & Play Solution Package, with 6x S/FTP 900/23cables with common FRNC jacket, both ends terminatedwith 6 S250 modules, and additional cable strain relief:CCAEDB-D2650-A200-C0installed in a CCHE Empty Panel for 6 LANscape modulesCCHE-CP00-LSCCHE Panel with Plug & Play Solution Package78 Corning Cable Systems


FutureCom EUniversal Test Cord for Channel TestingApplicationThe universal channel test cord can be used for acceptancetests of shielded FutureCom E Systems in conjunction withthe universal test adapter from Fluke or other test devicemanufactureres.One pair of these test cords is required for acceptance tests.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCCAEGB-D10M0-A030-C0 Universal Test Cord, for the acceptance test 1/1of the FutureCom E System in conjunctionwith the universal test adapter from Flukeor other test device manufacturers,2xRJ45, 4 pairs, 3 mFurther<strong>Information</strong>FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionSpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDCorning Cable Systems79


80 Corning Cable Systems


Table of contents5 FutureCom D5.1. System Descriptions & Data 825.2. Certificates 855.3. Cable5.3.1. Cat. 5 SF/UTP 300/24 FRNC/PVC Cable 865.3.2. Cat. 5 SF/UTP 300/24 FRNC, 16P Cable 885.3.3. Cat. 5 F/UTP 300/24 FRNC/PVC Cable 905.4. Connecting Hardware5.4.1. S100 e Module Overview 925.4.2. S100 e and S100 eL Module 935.5. Hardware5.5.1. S100 e Outlets and Patch Panels 945.5.2. S100 e Double Module Outlet 955.5.3. S100 eL Outlets and Patch Panels 965.5.4. Installation Options for Outlets 975.6. Patch Cords 985.7. Plug & Play 99Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsCorning Cable Systems81


FutureCom D SystemFutureCom D (2002) is Corning’s Class D system solution for symmetrical cabling. It fulfils all requirements of the currentISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D for links and Category 5 for the components. In addition,the FutureCom D system also satisfies Category 5e according to TIA/EIA-568-A-5.Face Plate“DELTAprofil”,80x80 mmWAXWSE-00001-C001andS100 e outlet, 2xRJ45,Cat.5, inclined,CAXDSD-S0201-C001FutureComSF/UTP 300/24 CableCCXDEF-I0047-C001-L7S100 e Module,1xRJ45, shielded,Cat. 5CAXDSM-00100-C001SF/UTP flex/26, green,2xRJ45- connectors,4 pairs,for10/100/1000 Base-TCCADGF-D4002-A020-C0SF/UTP flex/26, green,2xRJ45 connectors,4 pairs,for 10/100/1000Base-TCCADGF-D4002-A030-C019“ Patch Panel,formax. 24 LANscape®modules,with integrated cablestrain relief, 1 U,front panel ofhigh-grade steelWAXWSV-02400-C001A high level of system performace is achieved for the entirelink through the use of high-quality Category 5 connectiontechnology, cables and patch cords. The resulting performace,and future security, guarantees a high degree ofinvestment protection for the cabling.FutureCom D cabling that conforms to the standards issuitable for all recognized standardized voice and datatransmission procedures. This applies to analog voice transmission,ISDN, Token Ring, Ethernet (10-Base-T), Ethernet(100Base-TX) and Gigabit Ethernet (1000Base-T).Fully configured with RJ45 connectors and RJ45 modules, thecabling is application-neutral and can be used universally.The performance of the FutureCom D cabling system hasbeen certified by an independent test body (see certificate).Of course, all standardized EMC threshold values in Europeare observed.82 Corning Cable Systems


FutureCom D System Datafor Channel Class D (2002)Frequency in MHzMax. attenuation in dB*Attenuation in dB (typ. FutureCom D values)Min. NEXT in dB*NEXT in dB (typ. FutureCom D values)Min. ACR in dB*ACR in dB (typ. FutureCom D values)Min. ELFEXT in dB*ELFEXT in dB (typ. FutureCom D values)Min. return loss in dB*Return loss in dB (typ. FutureCom D values)* According to ISO/IEC 11801 (2002)The system values cited are only valid with regard to the use of original FutureCom D products. Derived values,such as PSACR, PSNEXT and PSELFEXT, maintain the required standard values but are not shown for clarity of presentation.14.02.360.070.056.067.757.470.017.019.04–3.5–60.0–56.5–60.0–20.010–5.8–55.0–49.2–52.0–20.0169.17.043.651.034.544.033.348.017.020.020–8.5–48.0–39.2–46.0–19.531.25–10.0–44.0–34.0–43.0–19.062.5Attenuation andNear-end Crosstalk (NEXT)NEXT in dB(typ. FutureCom D values)min. NEXT in dBAccording to standardmax. Attenuation in dBAccording to standardAttenuation in dB(typ. FutureCom D values)–16.0–38.0–22.0–38.0–17.010024.019.030.136.06.117.017.434.010.013.0FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFrequency in MHzFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableCorning Cable Systems83


FutureCom D System DataFar-end Crosstalk Relatingto the Far End (ELFEXT)ELFEXT in dB(typ. FutureCom D values)Min. ELFEXT in dBAccording to NormFrequency in MHzReturn LossReturn loss in dB(typ. FutureCom D values)min. return loss in dBaccording to standardFrequency in MHzTest SetupFutureCom D SF/UTP flex/26 Connecting Cable, 3 mS100 e Modules, 2xRJ4590 m FutureCom SF/UTP300/24S100 e Patch Panel 19“FutureCom D SF/UTP flex/26 Patch Cord, 3 mNominal intrinsic impedanceMax. DC loop resistance (according to standard)DC loop resistance (typ. FutureCom D values)Max. delay (according to standard)Max. delay (typ. FutureCom D values)100 40 18 0.05 µs 0.02 µs84 Corning Cable Systems


FutureCom D CertificatesFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems85


FutureCom D Cat. 5 CableSF/UTP 300/24 FRNC or PVCBraided shieldHalogen-free jacket,flame retardant or PVCTwisted pairFoil shielding4 shielded pairsPE foam-skin insulationCopper conductorAWG 24ApplicationThe FutureCom SF/UTP 300/24 cable is designed for applicationsof up to 300 MHz and its transmission characteristicsexceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5)specifications.FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for Gigabit-Ethernet. The cable has a streamlinedconstruction and low weight.The four stranded pairs are sheathed with a foil shield(F/UTP) and, additionally, with a braided shield (SF/UTP),which guarantee outstanding shielding characteristics. Thecable satisfies the standard for Class B interference radiation(EN 55022), as well as immunity (EN 55024), which enablesthe realization of CE-compatible networks.Color CodingPair 1Pair 2Pair 3Pair 4white with blue rings/bluewhite with orange rings/orangewhite with green rings/greenwhite with brown rings/brownFeaturesSF/UTP 300/24 cable, specified up to 300 MHzOutstanding electrical characteristicsFull braid copper shieldStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH) jacketFlame retardant according to IEC 60332-3, Category CPVC jacket, flame retardant, according to IEC 60332-1,Category BFRNC is non-corrosive according to IEC 60754-286 Corning Cable Systems


FutureCom D Cat. 5 CableSF/UTP 300/24 FRNC or PVCMechanical CharacteristicsElectrical Characteristics (at 20°C)Conductor insulationSheath materialArea/range of applicationPVC:FRNC:PE Foam skinHalogen-freeFoam-skinHalogen-free,flame retardantDry anddamp roomsLargest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 m1%>5000 M x km125 +/– 20%100 +/– 15%46 dB at 64 kHzTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallation0 to +50°C-20 to +60°C>_ 35 mm (for 2 x(4x2...) over flat side)>_ 50 mm (for 2 x(4x2...) over flat side)Unbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocityat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew>40 dB at 1 MHz>20 dB at 100 MHz0.74 x c4.5 ns/m7 ns/100 mCopper conductorAWG 24Electrical Characteristics (at 20°C)Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m*Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.12.065.377.062.375.063.872.060.870.075.0106.35.650.362.047.360.043.860.040.858.056.4168.07.247.259.044.257.039.754.036.752.051.8209.08.045.857.042.855.037.852.034.850.049.031.2511.410.142.954.039.952.033.948.030.946.043.962.516.514.438.450.035.448.027.940.024.938.035.610021.318.235.346.032.344.023.834.020.832.027.8250–29.5–38.5–36.5–22.1–20.19.0300–32.2–35.0–33.0–17.0–15.02.8* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Type designationSF/UTP 300/24 4PSF/UTP 300/24 4PSF/UTP 300/24 8PCategory5e (FRNC)5e (FRNC)5e (FRNC)No. ofPairs448Fire Load(MJ/m)0.460.460.96Max.HalogenfreeTensileStrength(N)YesYesYes8282164Outer(mm)6.16.16.2x13.5Weight Length(kg/km) (m)505010010003051000Order NumberCCXDEF-C0047-C001-L7CCXDEF-C0047-C001-X1*CCXDEF-C0087-C001-L7Flex Wire Cablefor Patch CordIndustrialCableSpecialCableSF/UTP 300/24 4PSF/UTP 300/24 4PSF/UTP 300/24 8P5e (PVC)5e (PVC)5e (PVC)4480.410.410.94NoNoNo82821645.85.86.2x13.5454597* X1 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.10003051000CCXDLF-C0047-C001-L7CCXDLF-C0047-C001-X1*CCXDLF-C0087-C001-L7Further<strong>Information</strong>Corning Cable Systems87


FutureCom D Cat. 5 CableSF/UTP 300/24 FRNC, 16PHalogen-freeexternal jacket,flame retardantFoilHalogen-free jacket,flame retardantBraided shieldFoil shieldingMetal-freecentral elementTwisted pair4 shielded pairsFoam-skin PEinsulationCopper conductorAWG 24ApplicationThe FutureCom SF/UTP 300/24 16P cable is specified forapplications up to 300 MHz and its transmissioncharacteristics exeed Category 5 (2002) and Category 5e(TIA/EIA 568-A-5).FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for Gigabit-Ethernet.The four stranded pairs are foil shielded (F/UTP) additionallywith a braided shield (SF/UTP), which guarantees outstandingshielding characteristics. The cable satisfies the standardfor Class B interference radiation (EN 55022), as well as immunity(EN 55024), which enables the realization of CEcompatiblenetworks. The Quattro configuration with ashared external sheath for the FutureCom SF/UTP 300/2416P cable, allows increased mechanical load and enablescost-optimized installation.Color CodingFeaturesPair 1Pair 2Pair 3Pair 4white with blue rings/bluewhite with orange rings/orangewhite with green rings/greenwhite with brown rings/brownSF/UTP 300/24 cable, specified up to 300 MHzOutstanding electrical characteristicsStranded pairs with foil shield and full braid shield. The4 cable cores are twisted around a non-metallic centralelementLow skew between the pairsHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 6103488 Corning Cable Systems


FutureCom D Cat. 5 CableSF/UTP 300/24 FRNC, 16PMechanical CharacteristicsConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-freeFoam-skin materialHalogen-free,flame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 85 mm>_ 120 mmAWG 24Electrical Characteristics (at 20°C)Largest resistance margin1%Insulation resistance>5000 M x kmImpedance Zo at 0.064 MHz125 +/– 20%Impedance Zo at 1 - 100 MHz100 +/– 15%Surface transfer impedance46 dB at 64 kHzUnbalance to ground dB/BZL = 100 m >40 dB at 1 MHzUnbalance to ground dB/BZL = 100 m >20 dB at 100 MHzPropagation velocityat >10 MHz (NVP x c)0.74 x cPropagation delay >_ 10 MHz4.5 ns/mDelay skew7 ns/100 mFutureCom E FutureCom 10 TEN FutureCom F IntroductionFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>FutureCom DElectrical Characteristics (at 20°C)Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m*Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.12.065.377.062.375.063.872.060.870.075.0106.35.650.362.047.360.043.860.040.858.056.4168.07.247.259.044.257.039.754.036.752.051.8209.08.045.857.042.855.037.852.034.850.049.031.2511.410.142.954.039.952.033.948.030.946.043.962.516.514.438.450.035.448.027.940.024.938.035.610021.318.235.346.032.344.023.834.020.832.027.8250–29.5–38.5–36.5–22.1–20.19.0* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)300–32.2–35.0–33.0–17.0–15.02.8<strong>Ordering</strong> <strong>Information</strong>Type designationCategory No. of PairsFire Load(MJ/m)Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)Length(m)Order NumberSF/UTP 300/24 16P5e164.04Yes32816.52801000CCXDEF-C0167-C001-L7Corning Cable Systems89


FutureCom D Cat. 5 CableF/UTP 300/24 FRNC or PVCFoil shieldingPVC orhalogen-free jacket,flame retardantTwisted pairFoil shieldingAdditional wirePE foam-skin insulationCopper conductorAWG 244 shielded pairsApplicationThe FutureCom F/UTP 300/24 Cable is designed for applicationsof up to 300 MHz and its transmission characteristicsexceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5)specifications.FutureCom cables are low-skew products, i.e. the skew betweenthe individual pairs are very low. This is increasinglyrequired for Gigabit-Ethernet. The cable has a streamlinedconstruction and low weight.The four stranded pairs are foil shielded (F/UTP). The cablesatisfies the standards for Class B interference radiation(EN 55022), as well as immunitiy (EN 55024), which enablesthe realization of CE-compatible networks.Color CodingFeaturesPair 1Pair 2Pair 3Pair 4white with blue rings/bluewhite with orange rings/orangewhite with orange rings/orangewhite with orange rings/orangeF/UTP 300/24 cable, specified up to 300 MHzOutstanding electrical characteristicsFull shielding with 2 foils and additional copper wireStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH) jacketFlame retardant according to IEC 60332-3, Category CPVC jacket, flame retardant according to IEC 60332-1,Category BNon-corrosive according to IEC 60754-2 (FRNC)90 Corning Cable Systems


FutureCom D Cat. 5 CableF/UTP 300/24 FRNC or PVCMechanical CharacteristicsElectrical Characteristics (at 20°C)Conductor insulationOuter jacketArea/range of applicationPVC:FRNC:PE foam skinHalogen-freeFoam-skinHalogen-free,flame retardantDry anddamp roomsLargest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzSurface transfer impedanceUnbalance to ground dB/BZL = 1000 m1%>5000 M x km125 +/– 20%100 +/– 15%46 dB at 64 kHzTemperature range (in motion)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallation0 to +50°C-20 to +60°C>_ 35 mm (for 2x(4x2...) over flat side)>_ 50 mm (for 2x(4x2...) over flat side)Unbalance to ground dB/BZL = 100 mUnbalance to ground dB/BZL = 100 mPropagation velocityat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew>40 dB at 1 MHz>20 dB at 100 MHz0.74 x c4.5 ns/m7 ns/100 mCopper conductorAWG 24Electrical Characteristics (at 20°C)Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m*Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.12.065.377.062.375.063.872.060.870.075.0106.35.650.362.047.360.043.860.040.858.056.4168.07.247.359.044.257.039.754.036.752.051.8209.08.045.857.042.855.037.852.034.850.049.031.2511.410.142.954.039.952.033.948.030.946.043.962.516.514.438.450.035.448.027.940.024.938.035.610021.318.235.346.032.344.023.834.020.832.027.8250–29.5–38.5–36.5–22.1–20.19.0300–32.2–35.0–33.0–17.0–15.02.8* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms to EN 50288-2-1)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Type designationF/UTP 300/24 4PF/UTP 300/24 4PF/UTP 300/24 8PCategory No. of Pairs5e5e5e448Fire Load(MJ/m)0.470.470.94Max.HalogenfreeStrength(N) (mm)Tensile Outer Weight(kg/km)YesYesYes82821646.1 406.1 406.2x13.5 82Length(m)10003051000Order NumberCCXDEE-C0047-C001-L7CCXDEE-C0047-C001-X1*CCXDEE-C0087-C001-L7Flex Wire Cablefor Patch CordIndustrialCableSpecialCableF/UTP 300/24 4PF/UTP 300/24 4P5e (PVC)5e (PVC)440.410.41NoNo82825.85.83636F/UTP 300/24 8P 5e (PVC) 80.94 No 164 6.2x13.5 79*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.10003051000CCXDLE-C0047-C001-L7CCXDLE-C0047-C001-X1*CCXDLE-C0087-C001-L7Further<strong>Information</strong>Corning Cable Systems91


FutureCom DModule OverviewFeaturesFully compatible with all modular LANscape® systemsWide range of installation optionsFew individual componentsHigh-level component densityIndividual shieldingHalogen freeFire class UL 94 V-0Optimized construction for bandwidths up to 300 MHz1500 connector cycles possibleProven IDC technology for conductors with AWG 24 toAWG 23Module reusable several timesIndividual Components of the S100 e ModuleS100 e Basic ModuleFeaturesWire management using TIA/EIA 568 A/B codingShorter assembly timesEasy handlingCompatible with FutureCom F/UTP and SF/UTP cablesWire Management92 Corning Cable Systems


FutureCom DS100 e and S100 eL ModulesFeaturesEasy and quick to install, no special tools requiredIDC connection (IDC = Insulation Displacement Contacts)High-level component densityUniversal application in all modular LANscape® andFutureCom componentsNegligible disturbance effect from interference by meansof the individual shielding of the modulesUtilization of additional cable strain reliefCAXCSN-00000-C001 is possible for increased pullingforces<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXDSM-00100-C001 S100 e Module, 1xRJ45, shielded, Cat.5 (2002), 1/1for wire diameter AWG 24 to AWG 23(F/UTP and SF/UTP cables), incl. copperconducting tape for installation inLANscape patch panels,outlets and floor box solutionsFutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionCAXDSM-00200-C001 S100 e Double Module, 2xRJ45, shielded, 1/1Cat.5 (2002), for wire diameter AWG 24to AWG 23 (F/UTP and SF/UTP cable),incl. copper conducting tape forinstallation in LANscape modular patchpanels, outlets and floor box solutionsHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordCAXGSM-00100-C001 S100 eL Module, 1xRJ45, shielded, Cat.5 (2002), 1/1for wire diameter AWG 23 to AWG 22(PiMF cable), incl. copper conducting tapefor installation in LANscapemodular patch panels,outlets and floor box solutionsA Class E link can be constructed in conjunctionwith a S/FTP data cable and the correspondingpatch cords.IndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems93


FutureCom DS100 e Outlets and Patch Panel<strong>Ordering</strong> <strong>Information</strong>S100 e OutletsUnit perOrder Number Description DeliveryS100 e Outlet, 2xRJ45,Cat. 5/Cat. 5e, shielded,inclined, incl. mountingframe with groundingflaps, 50x50 mm centralplate with designationwindow, screw fixings,copper conducting tape(without face plate)CAXDSD-S0201-C001 white, RAL 9010 1/1CAXDSD-S0202-C001 pearl white, RAL 1013 1/1S100 e Patch PanelUnit perOrder Number Description DeliveryCAXDSV-02400-C001 S100 e Patch Panel 19“, 1/1shielded,Cat.5/Cat.5e,including 24 FutureComS100 e modules andcopper conducting tape,with integrated cablestrain relief, 1 U,high-grade steel frontpanelPatch panel accessories please see page 156.94 Corning Cable Systems


FutureCom DS100 e Double Module Outlet<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXDSD-S0200-C001 S100 e Double Module Outlet, 1/12x RJ45, Cat. 5, inclined,incl. mounting frame withgrounding flaps andcopper conducting tape(suitable for Rutenbeckcompatiblecentral platesor face plates)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom UEFutureCom UDHardwareFurther<strong>Information</strong>Flex Wire Cablefor Patch CordIndustrialCableSpecialCableTelephone /ISDN ProductsFutureCom DInstallation OptionS100 e Double Module Outlet, 2x RJ45, Cat.5, inclined,incl. mounting frame and copper conducting tape.CAXDSD-S0200-C001For example, mounted with a Busch-Jaeger central plate andface plateS100 e Double Module Outlet with central plateand face plate (Busch-Jaeger)Corning Cable Systems95


FutureCom DS100 eL Outlets and Patch Panel<strong>Ordering</strong> <strong>Information</strong>S100 eL OutletsUnit perOrder Number Description DeliveryS100 eL Outlet,2xRJ45, Cat. 5/Cat. 5e,inclined, incl. mountingframe with groundingflaps, 50x50 mm centralplate with designationwindow, screw fixings,copper conducting tape(without face plate)CAXGSD-S0201-C001 white, RAL 9010 1/1CAXGSD-S0202-C001 pearl white, RAL 1013 1/1S100 eL Patch PanelUnit perOrder Number Description DeliveryCAXGSV-02400-C001 S100 eL Patch Panel 19“, 1/1shielded,Cat.5/Cat.5e,including 24 FutureComS100 eL modules andcopper conducting tape,with integrated cablestrain relief, 1 U,high-grade steel frontpanelPatch panel accessories please see page 156.A Class E link can be constructed using S100 eL patch panels and outlets, in conjunctionwith a S/FTP data cable and the corresponding patch cords.96 Corning Cable Systems


FutureCom DInstallation Options for OutletsOption 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined,for three LANscape® modules, white, RAL 9010:WAXWSE-S0301-C001equipped with two S100 e modulesCAXDSM-00100-C001with one MT-RJ module adapter frameLAXLSN-00101-C001with one MT-RJ adapter for multimode connectorADP-MTRJ-CNKFL-CLSand two blue SF/UTP flex/26 patch cordsCCADNF-D2002-A030-C0Combi-Frame “DELTAprofil”FutureCom F IntroductionFutureCom 10 TENFutureCom EDouble Surface Mount OutletOption 3: 3-Port frame set for the assembly of three LANscapefiber optic or FutureCom copper modules, inclined, includingmounting frame and one triple housing with designationwindow and dust protection flaps and 80x80 mmface plate, white, RAL 9010:WAXWSE-V0301-C001equipped with two gray labeling iconsWAXWSE-00003-C001one yellow labeling iconWAXWSE-00005-C001two S100 e ModulesCAXDSM-00100-C001and two gray SF/UTP flex/26 patch cordsOption 2: Surface mount outlet, inclined, includingmounting frame and central plate 50x 50 mm withdesignation window, screw fixed, white, RAL 9010:CAXDSD-S0201-C001equipped with one red labeling iconWAXWSE-00007-C001one gray labeling iconWAXWSE-00003-C001and one red SF/UTP flex/26 patch cordCCADNF-D5002-A020-C0combined with surface mount housingWAXWSE-00001-C003and one “DELTAfläche” face plateWAXWSE-00001-C002Frame-Set for Three Modules, inclinedFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems97


FutureCom DCat. 5 Patch Cords RJ45 to RJ45DescriptionFutureCom D patch cords consist of Cat. 5 flex cable withshielded RJ45 connectors at both ends. The flex cables havefour pairs and fully braided copper wire shielding. The patchcords are tested according to IEC 60332-1, Category B. Theyare available in various lengths and colors.FeaturesSF/UTP flex cable, specified up to 300 MHzApplication-neutral due to using all four pairsMinimum surface transfer impedance(


FutureCom DPlug and Play SolutionsApplicationThe S100 e Solution Packages are pre-terminated cablesections with S100 e modules at both ends. They are generallyoffered with FutureCom F/UTP 300/24 cables. Bothmodules are equipped with additional cable strain relief toallow higher pulling force during installation (the pullingforce is restricted by the cable). They enable Plug and Playinstallation and therefore significantly reduce installationtime. 100% factory testing reduces failures during installation.FutureCom F IntroductionFutureCom 10 TENFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>FutureCom E<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthS100 e Solution Package with F/UTP 300/24data cable, 4 pairs, FRNC jacket pre-terminatedwith two S100 e modulesand additional cable strain reliefCCADEE-B2044-A100-C0 S100 e Solution Package F/UTP 300/24 - 10 10 mCCADEE-B2044-A150-C0 S100 e Solution Package F/UTP 300/24 - 15 15 mCCADEE-B2044-A200-C0 S100 e Solution Package F/UTP 300/24 - 20 20 mCCADEE-B2044-A250-C0 S100 e Solution Package F/UTP 300/24 - 25 25 mCCADEE-B2044-A300-C0 S100 e Solution Package F/UTP 300/24 - 30 30 mCCADEE-B2044-A350-C0 S100 e Solution Package F/UTP 300/24 - 35 35 mCCADEE-B2044-A400-C0 S100 e Solution Package F/UTP 300/24 - 40 40 mCCADEE-B2044-A450-C0 S100 e Solution Package F/UTP 300/24 - 45 45 mCCADEE-B2044-A500-C0 S100 e Solution Package F/UTP 300/24 - 50 50 mCCADEE-B2044-A550-C0 S100 e Solution Package F/UTP 300/24 - 55 55 mCCADEE-B2044-A600-C0 S100 e Solution Package F/UTP 300/24 - 60 60 mCCADEE-B2044-A650-C0 S100 e Solution Package F/UTP 300/24 - 65 65 mCCADEE-B2044-A700-C0 S100 e Solution Package F/UTP 300/24 - 70 70 mCCADEE-B2044-A750-C0 S100 e Solution Package F/UTP 300/24 - 75 75 mCCADEE-B2044-A800-C0 S100 e Solution Package F/UTP 300/24 - 80 80 mCCADEE-B2044-A850-C0 S100 e Solution Package F/UTP 300/24 - 85 85 mCCADEE-B2044-A900-C0 S100 e Solution Package F/UTP 300/24 - 90 90 mCorning Cable Systems99


100 Corning Cable Systems


Table of contents6 FutureCom UE6.1. System Descriptions & Data 1026.2. Certificate 1056.3. Cable6.3.1. Cat. 6 U/UTP 250/23 Cable – FRNC or PVC 1066.4. Connecting Hardware6.4.1. U250 Module Overview 1086.4.2. Keystone Module 1096.4.3. U250 fx Module 1106.5. Hardware6.5.1. U250 Outlets and Patch Panel 1116.6. Patch Cords 1126.7. Plug & Play 1136.7. Test Cable 114FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareCorning Cable Systems101


FutureCom UE SystemFutureCom UE is a system solution developed by Corning for unshielded balanced cabling installations. It meets all requirementsof the standards ISO/IEC 11801 (2002), EN 50173-1 (2003) for Class D and E links and for Category 5 and 6 components.Face Plate“DELTAprofil”,80x80 mmWAXWSE-00001-C001U250 outlet, 2xRJ45,Cat.6, inclined,CAXVSD-S0201-C001FutureComU/UTP250/23 CableCCXVDE-B0042-C001-X1U250 module,1xRJ45, unshielded,Cat. 6CAXVSM-00100-C001U/UTP UEflex/Cat.6,blue,2xRJ45 connectors,4 pairs,CCAVGB-D2002-A020-C019“ Patch Panel,for up to24 LANscape®modules withintegrated cable strainrelief, 1 U,front panel ofhigh-grade steelWAXWSV-02400-C001Class E channel performance is achieved using high qualityCategory 6 connecting hardware, Category 6 cables and thecorresponding patch cords.On the basis of configuration with RJ45 connectors and RJ45modules, the cabling is application neutral and henceuniversally usable.A FutureCom UE cabling system built in compliance withthe standards is therefore highly suitable for all known,standardized voice and data transmission methods. This appliesfor example to analog voice transmission, ISDN, TokenRing, Ethernet (10Base-T), Fast Ethernet (100Base-TX) and GigabitEthernet (1000Base-T).The performance of the FutureCom UE cabling system hasbeen certified by an independent test body (see certificate).102 Corning Cable Systems


FutureCom UE System Datafor Channel Class E (2002)Frequency in MHzMax. attenuation in dB *Attenuation in dB (typ. FutureCom UE values)Min. NEXT in dB *NEXT in dB (typ. FutureCom UE values)Min. ACR in dB *ACR in dB (typ. FutureCom UE values)Min. ELFEXT in dB *ELFEXT in dB (typ. FutureCom UE values)Min. return loss in dB *Return loss in dB (typ. FutureCom UE values)* According to ISO/IEC 11801 (2002).The stated system data apply only when original FutureCom UE products are used. Derived values such as PSACR, PSNEXT,PSELFEXT meet the specified standard values but are omitted for clarity of presentation.14.01.865.078.061.076.263.373.019.021.0106.65.856.662.050.056.243.353.019.021.0209.38.351.657.042.348.737.247.017.520.062.516.915.243.448.026.532.827.337.014.020.010021.719.639.945.018.225.423.333.012.018.0155.527.625.236.742.09.016.819.429.010.117.020031.728.634.839.03.010.417.327.09.016.025036.032.233.137.0-2.84.815.325.08.015.0FutureCom F IntroductionFutureCom 10 TENFutureCom EAttenuation andNear-end Crosstalk (NEXT)NEXT in dB(typ. FutureCom UE values)min. NEXT in dBAccording to standardmax. Attenuation in dBAccording to standardAttenuation in dB(typ. FutureCom UE values)FutureCom UEFutureCom UDFrequency in MHzFrequency in MHzFurther<strong>Information</strong>SpecialCableIndustrialCableFutureCom DHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordCorning Cable Systems103


FutureCom UE System Datafor Channel Class E (2002)Far-end Crosstalk(ELFEXT)ELFEXT in dB(typ. FutureCom UEvalues)Min. ELFEXT in dBAccording to standardFrequency in MHzReturn lossReturn loss in dB(typ. FutureCom UE values)min. Return loss in dBAccording to standardFrequency in MHzTest SetupFutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3mU250 Outlet, 2xRJ4590 m FutureCom U/UTP250/23U250 Patch Panel 19“FutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3mNominal intrinsic impedanceMax. DC loop resistance (according to standard)DC loop resistance (typ. FutureCom UE values)100 40 18 104 Corning Cable Systems


FutureCom UE CertificateFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems105


FutureCom UE Cat. 6 CablesU/UTP 250/23 FRNC or PVCApplicationJacketFRNC or PVCCentral crossmemberTwisted pairCopper conductorAWG 23Foam skin PEinsulationThe FutureCom U/UTP 250/23 cable is designed for applicationsup to 250 MHz and provides transmission performanceexceeding Category 6 specifications.FutureCom cables are low skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglybeing requested for Gigabit Ethernet. Additional featuresare the slim design and low weight of the cables.FeaturesMechanical CharacteristicsOuter jacket FRNC Version:PVC Version:Area/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one time bendingMin. bending radius duringinstallationCopper conductorZero halogen,flame retardantPVC,flame retardantDry anddamp rooms0 to +50°C-20 to +60°C26 mm52 mmAWG 23U/UTP 250/23 cable, specified up to 250 MHzExcellent electrical characteristicsCentral cross member reduces risk of crushingor kinkingCentral cross member can be cut off easilyfor installation of connecting hardwareLow skew between the pairsLow weightFlame retardant to IEC 60332-1, Category BSpecial Features of FRNC VersionZero halogen version (ZH)Non corrosive to IEC 60754-2 (NC)Low smoke to IEC 61034 (LS)106 Corning Cable Systems


FutureCom UE Cat. 6 CablesU/UTP 250/23 FRNC or PVCElectrical Characteristics (at 20°C)Mutual Capacity56 nF/kmDC resistance70 /kmCharacteristic impedance100 +/– 15 %Coupling attenuation at 30 MHz 45 dBPropagation velocityat >10 MHz (NVP x C)0.68 x cPropagation delay >_ 10 MHz5.36 ns/mDelay skew30 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom DFutureCom UEFurther<strong>Information</strong>FutureCom EElectrical Characteristics (at 20°C)Frequency in MHzAttenuation in dB/100m *Typical values dB/100mNext in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.12.066.074.364.072.366.075.364.072.372.3106.06.059.359.357.357.350.055.347.052.353.3167.67.656.256.354.254.345.951.243.048.248.7208.58.554.854.852.852.844.049.341.046.346.331.2510.710.651.951.949.949.940.145.437.142.441.2FutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCable62.515.515.347.447.445.445.434.139.431.136.432.110019.919.644.344.342.342.330.035.327.032.324.725033.032.338.338.336.336.322.027.319.024.36.0* Standard: Requirements on 100 m installed Category 6 cable (conforms with EN 50288-6-1)<strong>Ordering</strong> <strong>Information</strong>Type designationU/UTP 250/23 4PU/UTP 250/23 4PU/UTP 250/23 4PU/UTP 250/23 4PCategory6666No. ofPairs4444Fire Load(MJ/m)0.560.560.520.52HalogenfreeMax.TensileStrength(N)100100100100Outer(mm)Weight Length(kg/km) (m)*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.YesYesNoNo6.06.05.85.84242393930510003051000Order NumberCCXVDE-B0042-C001-X1CCXVDE-B0042-C001-L7CCXVKE-B0042-C002-X1*CCXVKE-B0042-C002-L7Corning Cable Systems107


FutureCom UEModule OverviewFeaturesPaired installation (no untwisting of pairs required)Significantly faster installation timesEasy handlingCompatible with all FutureCom UE cablesFully compatible with all modular LANscape® outlets,patch panels and floor box solutionsWide range of installation optionsFew individual partsHigh level component densityHalogen-freeFire class UL94V-0Optimized design with circuit board for bandwidthsof more than 300 MHz1500 mating cycles possibleProven IDC termination for wires with AWG 24 to AWG 22Module re-usable up to several timesIndividual Components of the U250 ModuleDisassembled U250 Basic ModuleFeaturesWire management using TIA/EIA 568 A/B codingInstallation in pairs(no untwisting of the pairs is necessary)Rapid assembly timesEasy handlingCompatible with FutureCom Cat. 6 U/UTP cablesWire Management108 Corning Cable Systems


FutureCom UEU250 ModulesFeaturesEasy and quick to install, no special tools requiredIDC connection (IDC = Insulation Displacement Contacts)High-level component densityUniversal usage in all modular LANscape® andFutureCom componentsCategory 6 (2002), de-embedded<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryCAXVSM-00100-C001 U250 Module, 1xRJ45, unshielded, 1/1Cat. 6, for installation in LANscapemodular patch panels,outlets and floor box solutionsFurther<strong>Information</strong>FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordSpecialCableIndustrialCableFutureCom UDFutureCom UEU250 Keystone ModuleUnit perOrder Number Description DeliveryCAXKSM-00100-C001 U250 Keystone Module, 1/11 x RJ45, unshielded,Cat. 6. for installationin patch panels, outletsand floor box solutionswith keystone designCorning Cable Systems109


FutureCom UEU250 fx ModuleApplicationU250 fx Modules are used for the assembly of consolidationpoint cables with flexible wiresFeaturesFully compatible with all modular LANscape® connectinghardwareWide range of installation optionsMinimal number of partsProven IDC technology for AWG 24 and AWG 26 strandedwiresModule reusable several times1500 mating cycles possibleWire management with A/B printing (according toTIA/EIA 568)Paired installation (no untwisting of pairs required)Easy handlingCategory 6, de-embeddedIndividual Parts of the U250 fx ModuleRequirements for Consolidation Point CablesAdditional cable strain relief is neccessary for assemblingthe flex wire modulesCCS patch cords with RJ45 connectors are wired accordingto TIA/EIA 568 B; when using other single-ended preterminatedconnecting cables, they should be wiredaccording to the RJ45 connector schemeInstalled solid wire cables should have a lowerattenuation specification than the flexible cableAssembled U250 fx Module(with additional cable strain relief)<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXVSM-00100-C003 U250 fx Module, 1xRJ45, unshielded, Cat.6 1/1especially designed forconsolidation point cables withAWG 24/26 stranded wires,incl. additional cable strain relieffor mounting in LANscape hardware110 Corning Cable Systems


FutureCom UEU250 Outlets and Patch Panel<strong>Ordering</strong> <strong>Information</strong>U250 OutletsUnit perOrder Number Description DeliveryU250 Outlet, 2xRJ45,unshielded, Cat. 6, inclined,incl. mounting framewith grounding flaps,central plate 50x50 mmwith designation window,screw-fixed,(without face plate)CAXVSD-S0201-C001 white, RAL 9010 1/1CAXVSD-S0202-C001 pearl white, RAL 1013 1/1Further<strong>Information</strong>FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFutureCom UDSpecialCableIndustrialCableFutureCom UEU250 Patch PanelUnit perOrder Number Description DeliveryCAXVSV-02400-C001 U250 Patch Panel 19“, 1/1unshielded, Cat. 6, incl.24 FutureCom U250modules,with integratedcable strain relief,1 U, high-grade steelfront panelPatch panel accessories please see page 156.HardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordCorning Cable Systems111


FutureCom UECat. 6 Patch Cords RJ45 to RJ45DescriptionFutureCom UE patch cords consist of Category 6 flexiblecable, with unshielded RJ45 connectors at both ends. Thezero-halogen patch cords (LSZH) are non-corrosive(according to IEC 60754-2), low smoke (according to IEC61034) and flame retardant (according to IEC 60332-1,Category B). They are available in different lengths andcolors.FeaturesU/UTP flex cable, specified up to 250 MHzApplication-neutral due to using all four pairsOutstanding transmission characteristics according toChannel E (2002)Cat. 6<strong>Ordering</strong> <strong>Information</strong>CCAVGB - D 002 - A - C0121Select color.1 = gray2 = blue4 = green2Select length.010 = 1 meter020 = 2 meters030 = 3 meters050 = 5 meters060 = 6 meters100 = 10 meters112 Corning Cable Systems


FutureCom UEPlug & Play SolutionsApplicationThe U250 Solution Packages are pre-terminated cables withU250 modules at both ends. They are generally offered withFutureCom U/UTP 250/23 cables. Both modules areequipped with additional cable strain relief, to allow higherpulling force during insertion (the pulling force is restrictedby the cable only). They enable Plug and Play installationand therefore significantly reduce installation time.FutureCom F IntroductionFutureCom 10 TENFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>FutureCom DFutureCom E<strong>Ordering</strong> <strong>Information</strong>Order Number Description LengthSolution Package, U/UTP 250/23 cable,4 pairs, FRNC jacket pre-terminatedwith 2 U250 modulesand additional cable strain reliefCCAVDE-C1056-A100-C0 U250 Solution Package U/UTP 250/23 - 10 10 mCCAVDE-C1056-A150-C0 U250 Solution Package U/UTP 250/23 - 15 15 mCCAVDE-C1056-A200-C0 U250 Solution Package U/UTP 250/23 - 20 20 mCCAVDE-C1056-A250-C0 U250 Solution Package U/UTP 250/23 - 25 25 mCCAVDE-C1056-A300-C0 U250 Solution Package U/UTP 250/23 - 30 30 mCCAVDE-C1056-A350-C0 U250 Solution Package U/UTP 250/23 - 35 35 mCCAVDE-C1056-A400-C0 U250 Solution Package U/UTP 250/23 - 40 40 mCCAVDE-C1056-A450-C0 U250 Solution Package U/UTP 250/23 - 45 45 mCCAVDE-C1056-A500-C0 U250 Solution Package U/UTP 250/23 - 50 50 mCCAVDE-C1056-A550-C0 U250 Solution Package U/UTP 250/23 - 55 55 mCCAVDE-C1056-A600-C0 U250 Solution Package U/UTP 250/23 - 60 60 mCCAVDE-C1056-A650-C0 U250 Solution Package U/UTP 250/23 - 65 65 mCCAVDE-C1056-A700-C0 U250 Solution Package U/UTP 250/23 - 70 70 mCCAVDE-C1056-A750-C0 U250 Solution Package U/UTP 250/23 - 75 75 mCCAVDE-C1056-A800-C0 U250 Solution Package U/UTP 250/23 - 80 80 mCCAVDE-C1056-A850-C0 U250 Solution Package U/UTP 250/23 - 85 85 mCCAVDE-C1056-A900-C0 U250 Solution Package U/UTP 250/23 - 90 90 mCorning Cable Systems113


FutureCom UE Universal Test Cordfor Channel TestingApplicationThis universal channel test cord is suitable for acceptancetests of unshielded FutureCom UE systems in conjunctionwith the universal test adapters from Fluke or other manufacurers.One pair of these test cords is required for acceptance tests.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCCAVFG-D10M0-A030-C0 Universal test cord for the acceptance tests 1/1of the FutureCom UE System in conjuntionwith the universal test adapters from Fluke,or other test device manufactures,gray, 2xRJ45 connectors, 4 pairs, 3 m114 Corning Cable Systems


Table of contents7 FutureCom UD7.1. System Description & Data 1167.2. Certificates 1197.3. Cable7.3.1. U/UTP 100/24 Cable FRNC or PVC 1207.4. Connecting Hardware7.4.1. U100 e Module Overview 1227.4.2. U100 e Module 1237.5. Hardware7.5.1. U100 e Outlets and Patch Panel 1247.6. Patch Cords 125FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UECorning Cable Systems115


FutureCom UD SystemFutureCom UD (2002) is Corning’s Class D solution for unshielded balanced cabling. It meets all requirements of thestandard ISO/IEC 11801 (2002) and EN 50173-1 (2003) for Class D links and Category 5 components. In addition, theFutureCom UD also satisfies Category 5e according to TIA/EIA 566-A-5.Face Plate“DELTAfläche”,75x75 mmWAXWSE-00001-C002U100 e outlet, 2xRJ45,Cat.5, inclined,CAXUSD-S0201-C001FutureComU/UTP100/24 CableCCXUEE-A0047-C001-L7U100 e module,1xRJ45, unschielded,Cat. 5CAXUSM-00100-C001U/UTP flex/26,gray,2xRJ45 connectors,4 pairs, for10/100/1000 Base-TCCAUGE-D1002-A030-C019“ Patch Panel,for up to24 LANscape®modules withintegrated strain relief,1 U, front panel ofhigh-grade steelWAXWSV-02400-C001Class D (2002) channel performance is achieved through theuse of high quality Category 5 connecting hardware, cablesand patch cords.On the basis of configuration with RJ45 connectors and theRJ45 module, the cabling is application neutral and henceuniversally usable.A FutureCom UD cabling system built in compliance withthe standards is suitable for standardized voice and datatransmission methods. This applies for example to analogvoice transmission, ISDN, Token Ring, Ethernet (10-Base-T),Fast Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T).The performance of the FutureCom UD cabling system hasbeen certified by an independent test body (see certificate).116 Corning Cable Systems


FutureCom UD System Datafor Channel Class D (2002)Frequency in MHzMax. attenuation in dB *Attenuation in dB (typ. FutureCom UD values)Min. NEXT in dB *NEXT in dB (typ. FutureCom UD values)Min. ACR in dB *ACR in dB (typ. FutureCom UD values)Min. ELFEXT in dB *ELFEXT in dB (typ. FutureCom UD values)Min. return loss in dB *Return loss in dB (typ. FutureCom UD values)* According to ISO/IEC 11801 (2002).The stated system data apply only when original FutureCom UD products are used. Derived values such as PSACR, PSNEXT,PSELFEXT meet the specified standard values but are omitted for clarity of presentation.FrequencyininMHzMHzFrequency in MHz142.460.365.057.862.657.067.017.019.044.53.950.655.046.151.145.057.017.021.0107.06.344.051.037.044.737.049.017.022.0169.28.040.646.531.438.532.945.017.022.02010.39.439.045.028.735.631.043.017.022.031.2512.811.535.740.022.930.527.039.015.120.162.518.516.030.635.512.119.521.133.012.117.0Attenuation andnear-end crosstalk (NEXT)NEXT in dB(typ. FutureCom UD values)min. NEXT in dBAccording to standardmax. Attenuation in dBAccording to standard10024.021.927.132.03.110.117.029.010.115.0Attenuation in dB(typ. FutureCom UD values)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFurther<strong>Information</strong>SpecialCableFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableCorning Cable Systems117


FutureCom UD System DataEqual level far-end crosstalk(ELFEXT)ELFEXT in dBtyp. FutureCom UD values)Min. ELFEXT in dBAccording to standardFrequency in MHzReturn loss in dBReturn loss in dB(typ. FutureCom UD values)min. Return loss in dBAccording to standardFrequency in MHzTest SetupFutureCom UD Patch Cord U/UTP flex/26, 2mU100 e FutureCom Modules, 2 x RJ4590 m FutureCom U/UTP100/24U100 e Patch Panel 19“FutureCom UD Patch Cord U/UTP flex/26, 2mNominal impedanceMax. DC loop resistance (according to standard)DC loop resistance (typ. FutureCom UD values)100 40 18 118 Corning Cable Systems


FutureCom UD Certificatesfor Channel Class D (2002)Further<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems119


FutureCom UD Cat. 5e CablesU/UTP 100/24 FRNC or PVCApplicationJacketFRNC or PVCTwisted pairCopper conductorAWG 24Foam skin PEinsulationThe FutureCom U/UTP 100/24 cable is designed for applicationsup to 100 MHz and provides transmission performanceexceeding Category 5 and 5e specifications.FutureCom cables are low skew products, i.e. the skew betweenthe individual pairs is very low. This is increasingly beingrequested for Gigabit Ethernet. Additional features arethe slim design and low weight of the cables.FeaturesMechanical CharacteristicsConductor insulation PVC:FRNC:Outer jacketPVC:FRNC:Area/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorPE foam-skin materialZero Halogenfoam-skin materialFlame retardantZero Halogenflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 25 mm (for 2x(4x2...) over flat side)>_ 40 mm (for 2x(4x2...) over flat side)AWG 24U/UTP 100/24 cable, specified up to 100 MHzCore and pairs are unshieldedExcellent electrical valuesSlim designLow weightHalogen-free (LSZH) jacket, flame retardant toIEC 60332-3, Category CPVC jacket, flame retardant to IEC 60332-1, Category BColor CodingPair 1white with blue rings/bluePair 2white with orange rings/orangePair 3white with green rings/greenPair 4white with brown rings/brown120 Corning Cable Systems


FutureCom UD Cat. 5e CablesU/UTP 100/24 FRNC or PVCElectrical Characteristics (at 20°C)Max. resistance unbalance3%Insulation resistance>5000 x kmImpedance Zo at 0.064 MHz125 +/– 20%Impedance Zo at 1 – 100 MHz100 +/– 15%Return loss: 4 – 10 MHz>_ 20 + 5 log (f)Return loss: 10 – 20 MHz>_ 25 dBReturn loss: > 20 MHz>_ 25 dB - 7 log (f/20)Longitudinal conversion loss dB/ref. > 43 dB at 64 kHzlength = 1000mMutual capacity45 pF/mPropagation velocityat >10 MHz (NVP x c)0.74 x cPropagation delay >_ 10 MHz4.5ns/mDelay skew7 ns/100 mElectrical Characteristics (at 20°C)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.11.965.377,462.374.063.868.060.866.074.1106.35.950.365.547.360.043.849.040.847.056.1168.07.447.362.244.256.039.745.036.743.050.6209.08.445.859.742.854.037.842.034.840.047.6* Standard: Requirements on 100 m installed Category 5e cable (conforms with EN 50288-3-1)31.2511.410.542.957.739.951.033.940.030.938.042.562.516.515.138.449.635.447.027.933.024.931.033.910021.319.335.346.632.344.023.828.020.826.026.7FutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Type designationU/UTP 100/24 4PU/UTP 100/24 8PU/UTP 100/24 4PU/UTP 100/24 4PU/UTP 100/24 8PCategory5e5e5e5e5eNo. ofPairs48448Fire Load(MJ/m)0.591.220.320.320.76HalogenFreeMax.Tensile OuterStrength(N) (mm)6.26.0x13.05.05.05.0x12.0*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.YesYesNoNoNo821648282164Weight Length(kg/km) (m)44882828561000100010003051000Order NumberCCXUEE-A0047-C001-L7CCXUEE-A0087-C001-L7CCXULE-A0047-C004-L7CCXULE-A0047-C004-X1*CCXULE-A0087-C004-L7Flex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems121


FutureCom UDModule OverviewFeaturesFully compatible with all modular LANscape®and FutureCom systemsWide range of installation optionsFew individual partsHigh level component densityOptimized design for bandwidths of up to 100 MHz1500 mating cycles possibleProven IDC termination for wires with AWG 24to AWG 23Module re-usable several timesHalogen-freeFire class UL 94V-0Individual Parts of the U100 e ModuleU100 e Basic ModuleFeaturesWire management using TIA/EIA 568 A/B codingShorter installation timesEasy handlingCompatible with FutureCom U/UTP Cat. 5 cablesWire Management122 Corning Cable Systems


FutureCom UDU100 e ModuleFeaturesEasy and quick to install, no special tools requiredIDC connection (IDC = Insulation Displacement Contact)High level component densityUniversally usable in all modular LANscape® componentsFutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXUSM-00100-C001 U100 e module, 1xRJ45, unshielded, 1/1Cat. 5 (2002) for installation in modularLANscape patch panels,outlets and floor box solutionsFutureCom 10 TENFutureCom EFutureCom DFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UECorning Cable Systems123


FutureCom UDU100 e Outlets and Patch Panel<strong>Ordering</strong> <strong>Information</strong>U100 e OutletsUnit perOrder Number Description DeliveryU100 e Outlet,2xRJ45, Cat. 5/Cat. 5e,unshielded, inclined,incl. mounting framewith grounding flaps,50x50 mm centralplate with designationwindow, screw fixings,(without face plate)CAXUSD-S0201-C001 white, RAL 9010 1/1CAXUSD-S0202-C001 pearl white, RAL 1013 1/1U100 e Patch PanelUnit perOrder Number Description DeliveryCAXUSV-02400-C001 U100 e Patch Panel 19“, 1/1unshielded, Cat. 5/Cat. 5e,including 24 FutureComU100 e modules,with integrated cablestrain relief, 1 U,high-grade steel frontpanelPatch panel accessories please see page 156.124 Corning Cable Systems


FutureCom UDCat. 5 Patch Cords RJ45 to RJ45DescriptionFutureCom UD system patch cords consist of Category 5flexible cables and are terminated with unshielded RJ45connectors at both ends. The patch cords are flameretardant according to IEC 60332-1, Category B. They areavailable in various lengths and colors.FeaturesU/UTP flex cable, specified up to 100 MHzApplication-neutral due to using all four pairsOutstanding transmission characteristics according toChannel D (2002)Category 5 (2002) or 5e according to TIA/EIAFutureCom D FutureCom E FutureCom 10 TEN FutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>CCAU E - D 002 - A - C01231 Select cable type.G = FRNCN= PVCFutureCom UEFutureCom UDHardware2Select color.1 = gray2 = blue3 = yellow4 = green5 = red6 = blackTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord3Select length.005 = 0.5 meters010 = 1 meter020 = 2 meters030 = 3 meters040 = 4 meters050 = 5 meters060 = 6 metersIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems125


126 Corning Cable Systems


Table of contents8 Hardware8.1. Outlets and Outlet Accessories8.1.1. Standard Outlets 1288.1.2. Metal Outlets 1388.2. Accessories for Floor Box Solutions 1448.3. Patch Panel and Patch Panel Accessories 1528.4. Consolidation Point Housing 1578.5. Tools and Accessories 1588.6. 1000 RT 162FutureCom 10 TENFutureCom EFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom F IntroductionCorning Cable Systems127


Outlets and Outlet AccessoriesApplicationThe LANscape® System offers outlet solutions for all installationoptions and mounting methods. There are variousstyles available for surface, flush or raceway mounting.Using various frame sets from the LANscape system, outletconfigurations with 1 to 6 ports can be individually combined.The frame sets with a central plate size of 50 x 50 mmcan be combined with our “DELTAprofil” and “DELTAfläche”face plates, as well as those of other manufacturers.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryBlank Cover, 1 positionfor installation in modularLANscape patch panels,outlets and floor box solutionsWAXWSM-00101-C001 white, RAL 9010 6/1WAXWSM-00108-C001 black, RAL 9005 6/1Frame Sets for the Individual Configuration of OutletsUnits perOrder Number Description DeliveryFrame Set, straight,for 2 FutureCom modules,including mounting frameand 50x50 mm central platewith designation window, screw fixingWAXWSE-G0201-C001 white, RAL 9010 1/1WAXWSE-G0202-C001 pearl white, RAL 1013 1/1128 Corning Cable Systems


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Frame Sets for the Individual Configuration of OutletsUnits perOrder Number Description DeliveryFrame Set, inclined, with groundingflap, for 2 LANscape® modules,including mounting frame and50x50 mm central plate with designationwindow, screw fixingWAXWSE-S0201-C001 white, RAL 9010 1/1WAXWSE-S0202-C001 pearl white, RAL 1013 1/1FutureCom F IntroductionFutureCom 10 TENFutureCom EDesign Line - Special Color OptionsFrame Set, inclined, with groundingflap, for 2 LANscape® modules,including mounting frame and50x50 mm central plate with designationwindow, screw fixingWAXWSE-S0203-C001 gray, RAL 7035 1/1FutureCom DFutureCom UEFutureCom UDFrame Set, inclined, with groundingflap, for 2 LANscape® modules,including mounting frame and50x50 mm central plate with designationwindow, screw fixingWAXWSE-S0208-C001 black, RAL 9005 1/1HardwareTelephone /ISDN ProductsProjecting Frame Set for the Individual Configuration of OutletsUnits perOrder Number Description DeliveryFrame Set, inclined, projecting,for 2 LANscape modules,including mounting frame and50x50 mm central platewith designation windowand dust protection flapsWAXWSE-V0201-C001 white, RAL 9010 1/1WAXWSE-V0202-C001 pearl white, RAL 1013 1/1Flex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems129


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Frame Set, inclined, projecting, 3- or 6-Port OutletUnits perOrder Number Description DeliveryFrame Set, inclined, projecting,for 3 LANscape® modules,including mounting frameand triple housingwith designation window,dust protection flapsand face plate 80x80 mmWAXWSE-V0301-C001 white, RAL 9010 1/1WAXWSE-V0302-C001 pearl white, RAL 1013 1/1Frame Set, inclined, projecting,for 6 LANscape modules,including mounting frameand two triple housingswith designation window,dust protection flaps andface plate 151x80 mmWAXWSE-V0601-C001 white, RAL 9010 1/1WAXWSE-V0602-C001 pearl white, RAL 1013 1/1Installation Option: 6-Port Frame Set for the mounting of 6LANscape modules, inclined, including mounting frame andtwo triple housings with designation window and dust protectionflaps and face plate 151 x 80 mm, white, RAL 9010;WAXWSE-V0601-C001equipped with two S250 modulesCAXESM-00100-C001two black labeling iconsWAXWSE-00008-C001four blue labeling iconsWAXWSE-00004-C001and two blue S/FTP/flex patch cablesCCAEGB-G2002-A030-C0Outlet for 6 modules, Inclined130 Corning Cable Systems


Outlets and Outlet AccessoriesLabeling Icons and Designation LabelsAll frame sets with a 50x50 mm central plate as well as the3- and 6-port frame sets offer the opportunity to code eachport with labeling icons. The icons indicate port applicationsand show a telephone or a computer (LAN operation). Theyare available in six different colors. Furthermore, theseframe sets have a designation window with a clear cover, forinserting a designation label.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSE-00003-C001 Labeling Icon, computer/telephone, 120/1gray, RAL 7042WAXWSE-00004-C001 Labeling Icon, computer/telephone, 120/1blue, RAL 5015WAXWSE-00005-C001 Labeling Icon, computer/telephone, 120/1yellow, RAL 1021WAXWSE-00006-C001 Labeling Icon, computer/telephone, 120/1green, RAL 6029WAXWSE-00007-C001 Labeling Icon, computer/telephone, 120/1red, RAL 3000WAXWSE-00008-C001 Labeling Icon, computer/telephone, 120/1black, RAL 9005Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionWAXWSE-00001-C009 DIN A4 Title Strip Sheet, 10/1with 150 designation labelsfor LANscape® outlets, white,e.g. for labeling using a PC-printerFurther<strong>Information</strong>Telephone /ISDN ProductsFlex Wire Cablefor Patch CordSpecialCableIndustrialCableCorning Cable Systems131


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Face Plates for 50 x 50 mm Central PlatesUnits perOrder Number Description Delivery“DELTAprofil” Face Plate, 80x80 mm,for LANscape® outlets with50x 50 mm central plateWAXWSE-00001-C001 white, RAL 9010 1/1WAXWSE-00002-C001 pearl white, RAL 1013 1/1“DELTAfläche” Face Plate, 75x75 mm,for LANscape outlets with50x 50 mm central plateWAXWSE-00001-C002 white, RAL 9010 1/1WAXWSE-00002-C002 pearl white, RAL 1013 1/1Surface Mount Housing for “DELTAfläche” OutletsUnits perOrder Number Description Delivery“DELTAfläche” Surface Mount Housing,for the individual configuration ofLANscape outlets, 75x75 mmWAXWSE-00001-C003 white, RAL 9010 1/1WAXWSE-00002-C003 pearl white, RAL 1013 1/1132 Corning Cable Systems


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Combi-FramesUnits perOrder Number Description Delivery“DELTAprofil” Combi-Frame, 80x80 mm,inclined, for 3 LANscape® modulesWAXWSE-S0301-C001 white, RAL 9010 1/1WAXWSE-S0302-C001 pearl white, RAL 1013 1/1FutureCom F IntroductionFutureCom EFutureCom 10 TEN“DELTAfläche” Combi-Frame, 75x75 mm,inclined, for 3 LANscape modulesWAXWSE-S0301-C002 white, RAL 9010 1/1WAXWSE-S0302-C002 pearl white, RAL 1013 1/1FutureCom DFutureCom UEInstallation OptionsFutureCom UD“DELTAprofil”Combi-Frame“DELTAprofil” Combi-FrameOption 1: “DELTAprofil” Combi-Frame, 80x80 mm,inclined , white, RAL 9010;WAXWSE-S0301-C001equipped with two S250 Modules,CAXESM-00100-C001and one LC Duplex Module for multimode connectorsLAXLSM-00101-C007Option 2: “DELTAfläche” Combi-Frame, 75x75 mm,inclined , white, RAL 9010;WAXWSE-S0301-C002equipped with two S100 e Modules,CAXDSM-00100-C001and one single MT-RJ Module for single-mode/multimodeconnectorsLAXLSM-00101-C004HardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems133


Outlets and Outlet AccessoriesBrackets for Raceway MountingThe following brackets can be used for the quick and simpleinstallation of outlets and frame sets in raceways.They support the minimum bend radius requirements forcopper and fiber optic cables. In order to separate networkcomponents from power systems, the brackets are suppliedwith a removable half-shell partition, which can beoptionally inserted.An additional advantage of the half-shell partition is theprotection of fiber optic connections against mechanicaldamage during pulling of new cables. The brackets aresuitable for Tehalit and Ackermann raceways with T-groovemounting.<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSE-00001-C010 Brackets for Raceway Mounting of outlets 1/1and frame sets, T-groove mounting,height 50 mm, with half-shell partition,white, RAL 9010WAXWSE-00008-C002 Brackets for Raceway Mounting of outlets 1/1and frame sets, T-groove mounting,height 55 mm, with half-shell partition,black, RAL 9005134 Corning Cable Systems


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSE-00001-C008 Surface Mount Housing, 67x110 mm, 1/1for combi-frame (67x110 mm),white, RAL 9010Further<strong>Information</strong>Telephone /ISDN ProductsFutureCom F IntroductionFutureCom 10 TENFutureCom EWAXWSE-V0201-C004 Combi-Frame, 67x110 mm, 1/1for installation of twosingle LANscape® modules,inclined,white, RAL 9010CAXCSE-G0201-C001 Combi-Frame, 45x45 mm, 1/1with self-closing shutters forthe installation of 2 FutureCommodules, straight,white, RAL 9010Hardware FutureCom UD FutureCom UE FutureCom DCombi-Frames for VanGeel ColumnsUnits perOrder Number Description DeliveryCAXCSE-G0201-C002 Combi-Frame for VanGeel Columns, 1/145x45 mm, with self-closing shuttersfor the installation of 2 FutureCommodules, straight,white, RAL 9010Flex Wire Cablefor Patch CordIndustrialCableSpecialCableCorning Cable Systems135


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSE-00001-C004 Surface Mount Housing, 87x87 mm, 1/1including two screws for face plate(87x87 mm),white, RAL 9010WAXWSE-00001-C005 Face plate, 87x87 mm, 1/1for one module housing,including two metric screwsand two whitworth screws,for face plate mounting in installationoutlets, white, RAL 9010WAXWSE-00001-C006 Surface Mount Housing, 87x147 mm, 1/1including two screws for face plate(87x147 mm),white, RAL 9010WAXWSE-00001-C007 Face Plate, 87x147 mm, 1/1for two module housings,including two metricscrews and two whitworth screws,for face plate mounting in installationoutlets, white, RAL 9010136 Corning Cable Systems


Outlets and Outlet Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSE-V0201-C001 Module Housings with 1/1self-closing shutters, projecting,inclined, for face plates(147x87 mm and 87x87 mm)for the installation of 2 FutureCommodules, white, RAL 9010FutureCom F IntroductionFutureCom 10 TENWAXWSE-V0201-C002 Universal Module Housing, 1/1projecting, inclined,for face plates (147x87 mm and87x87 mm) for the installation of2 FutureCom modules,central partition provided,white, RAL 9010CAXCSE-U0201-C001 Surface Combi-Frame Set, 75x65 mm, 1/1with self-closing shutters for theinstallation of 2 FutureCom modules,straight, white, RAL 9010Hardware FutureCom UD FutureCom UE FutureCom D FutureCom EFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsCorning Cable Systems137


Metal Outlets for Industrial ApplicationsApplicationThe 2-port LANscape® industrial metal outlets withintegrated cable strain relief can be equipped with anyLANscape fiber optic or copper modules. The outlet issuitable for harsh environmental conditions and can bemounted on a surface, as well as in different configurations(see page 139) on top hat rails (35 mm DIN rails).FeaturesIntegrated cable strain relief for two individualcables (separate assembly possible)Metal construction suitable for harsh environmentalconditions in industrial surroundingsConductive housing for shielded FutureCom modulesNon-detachable designation labelCable entry with brush strip provides dust protectionregardless of cable diameterNon-detachable housing fastening screwHorizontal and vertical top hat rail mountingExcess length storage for fiber without exceedingminimum bending radiusRetrofitting and re-equipping possible without completedisassembly (2-piece housing)<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryWAXWSD-V0208-C001 2-Port Metal Outlet 1/1for Industrial Applications,60x65x121 mm (HxWxD),for the installationof 2 LANscape modules,inclined, projecting,with designation window,metal construction withintegrated cable strain relief,anthracite, RAL 7016 ** Other colors upon request138 Corning Cable Systems


Metal Outlets for Industrial ApplicationsMounting on a Top Hat Rail (35 mm DIN rails) / On a SurfaceFutureCom 10 TENFutureCom F IntroductionHorizontal top hat rail:Upper top hat rail clipInstallation Option2-port Metal Outlets for Industrial Applications, 60 x 65 x 121 mm (HxWxD), for the installation of two LANscape® modules,inclined, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016;WAXWSD-V0208-C001Horizontal top hat rail:Middle top hat rail clipHorizontal top hat rail:Lower top hat rail clipVertical top hat rail:Middle top hat rail clip,rotated 90°The top hat rail clips can be assembled in four different positions, since distributor cabinets (e.g. robot or machine controls)often have different distances between the top hat rails and the cabling conduits. In addition, there are two diagonally positioneddrilled holes in the back of the outlet housing, so that the metal outlet can be mounted directly on the surface by removingthe top hat rail clip.equipped with one S1200 Module,Cat. 7CAXFSM-00100-C001in one S1200 Module AdapterCAXFSN-00110-C001Assembled with S/STP1200FutureCom cableCCXFCB-L0047-C001-L7and with one MT-RJ ModuleLAXLSM-00101-C004and one MT-RJ UniCam® Connector92-051-97-P-Eassembled with protectedMiniZip FO industrial cableJ-VH(2ZN)H 2X1G50/125FutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCable(Left side) Closed metal outlets(Right side) Basic housing with mounted copper and fiber optic cablesFurther<strong>Information</strong>Corning Cable Systems139


4-Port Metal Outlets for Industrial ApplicationsApplicationThe 4-port LANscape® industrial metal outlets withintegrated cable strain relief can be equipped with anyLANscape fiber optic or copper modules. The outlet issuitable for harsh environmental conditions and can bemounted on a surface, as well as on a top hat rail (35 mmDIN rails).FeaturesIntegrated cable strain relief for 4 individual cables(separate mounting is possible)Metal construction suitable for harsh environmentalconditions in industrial surroundingsConductive housing for shielded FutureCom modulesNon-detachable designation labelCable diameter-independent and dust-protected cableentryIntegrated grounding pinNon-detachable housing fastening screwHorizontal and vertical top hat rail mounting is possibleSplice holder for 12 crimp-splice connections includingexcess length storage for FO pigtails and cables, can beretrofitted at any timeRetrofitting and re-equipping without completedisassembly due to the two-part housing<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryWAXWSD-V0408-C001 4-Port Metal Outlet 1/1for Industrial Applications,79x101x121 mm (HxWxD),for the installation ofmax. 4 LANscape modules,inclined, with designationwindow, metal constructionwith integrated cable strainrelief, integrated groundingpin, easy retrofitting of theoptional splice tray,WAXLSD-0000-C001,anthracite, RAL 7016 ** other colors upon request140 Corning Cable Systems


4-Port Metal Outlets for Industrial ApplicationsInstallation Option4-port Metal Outlet for Industrial Applications,79 x 101 x 121 mm (HxWxD), for theinstallation of max. 4 LANscape® modules,inclined, with designation window,FutureCom F Introductionmetal construction with integrated cablestrain relief, integrated grounding pin,anthracite, RAL 7016;WAXWSD-V0408-C001FutureCom 10 TENequipped with one S1200 module,Cat.7CAXFSM-00100-C001one a S1200 moduleCAXFSN-00110-C001one S250 module, Cat. 6Closed metal outletBasic housingwith mounted copper cablesFutureCom D FutureCom ECAXESM-00100-C001and with one SC duplex moduleLAXLSM-00201-C001with dust protection flap for SC duplexFutureCom UEmultimode connector, beigeLAXLOK-00013-C001equipped with splice trayWAXLSD-00000-C001FutureCom UDincl. two stored crimp-spliceconnections of two SC pigtailsHardware.... mounted on a top hat rail<strong>Ordering</strong> <strong>Information</strong>Basic housing with mounted copper andFO cables incl. splice trayUnits perOrder Number Description DeliveryWAXLSD-00000-C001 Splice Tray for 4-Port Metal Outlets, 1/115x96x92 mm (HxWxD),with splice organizer for12 crimp-splice connections,separate excess length storagewhich support the minimumbend radius requirementsfor fiber optic pigtails and cables,anthracite, RAL 7016 ** other colors upon requestSplice tray (rear side) withmounted splice connectionsTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems141


4-Port Metal Outlets for Industrial Applicationswith Security FeaturesDescriptionFeaturesThe LANscape® metal outlet is constructed entirely frommetal and is intended for wall surface mounting ormounting in false floors. It offers space for four LANscape®fiber optic or copper modules. The outlet is especiallydesigned for security applications.Metal construction suitable for harsh environmentalconditionsCable strain relief for individual cables at cable entry inthe basic housing using cable tiesConnection protection and security against accidental orunauthorized accessFastening of the housing cover using a central screw,which can be protected, e.g. using a security labelExcess length storage for fiber optic cable, maintainingthe minimum bending radiusBasic housing designed to be conductive(important when using FutureCom copper modules)Standard fastening shape (60 mm hole spacing)Horizontal and vertical top hat rail mountingBasic housing with mountedcopper and FO cableClosed metal outletwith mounted copper andFO cables<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryWAXWSD-U0407-C001 Metal Outlet, 4-Port 1/145x93x143.5 mm (HxWxD),for the installation of 4LANscape individualmodules, straight, metalconstruction withintegrated strain relief,patchcord protectionand excess length storagefor FO cables,red, RAL 3000 *WAXWSD-U0408-C001 Metal Outlet, 4-Port 1/145x93x143.5 mm (HxWxD),for the installation of 4LANscape individualmodules, straight, metalconstruction withintegrated strain relief,patchcord protectionand excess length storagefor FO cables,anthracite, RAL 7016 ** other colors upon request142 Corning Cable Systems


4-Port Metal Outlets for Industrial ApplicationsDescriptionThe LANscape® metal outlet is constructed entirely frommetal and is intended for wall surface mounting, racewaymounting or mounting in false floors. It offers space forfour four LANscape fiber optic or copper modules.FeaturesMetal construction, suitable for harsh environmentalconditionsCable strain relief for individual cables in the basichousing using cable tiesFastening of the housing cover using a central screwExcess length storage for FO cables of max. length0.6-1.0 m, for maintaining the minimum bending radiusBasic housing designed to be conductive(important when using copper modules)Standard fastening shape (60 mm hole spacing)Horizontal and vertical top hat rail mountingFutureCom F IntroductionFutureCom 10 TENFutureCom EClosed metal outletswith mountedcopper cables<strong>Ordering</strong> <strong>Information</strong>Unit perOrder Number Description DeliveryWAXWSD-U0407-C002 Metal Outlet, 4-Port 1/145x93x87 mm (HxWxD),for the installation of 4LANscape individualmodules, straight,metal construction withintegrated strain relief andexcess length storagefor FO cables,red, RAL 3000 *FutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordWAXWSD-U0401-C002 Metal Outlet, 4-Port 1/145x93x87 mm (HxWxD),for the installation of 4LANscape individualmodules, straight,metal constructionwith integrated strainrelief and excess lengthstorage for FO cables,white, RAL 9010 ** Other colors upon requestIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems143


Accessories for Floor Box SolutionsApplicationsThe LANscape® mounting panels for floor boxes are suitablefor all fiber optic and copper modules.DescriptionThe modular system provides floor box solutions up to nineports for floor boxes manufactured by Ackermann,Kleinhuis, Electraplan, VanGeel, OBO Bettermann andVergokan.The cable strain relief is fixable in three different positions.Self-adhesive designation strips are available for all ports.Splicing of pigtails is possible in the floor box in combinationwith the protection box and a special splice tray.Mounting in the Ackermann GES4 Floor BoxFeaturesInstallation OptionSuitable for all LANscape fiber optic or copper modulesRobust metal construction, blackNo additional mounting inserts requiredIntegrated individual strain relief of each cable(regardless of the diamter)Strain relief mountable in various positionsNo screws necessaryIntegrated grounding pinDesignation windowsUp-gradeable with protection box for fiber optic cablingUp-gradeable with special splice traysMounting panel for Ackermann floor boxes GES 2, GES 4,GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 (outermounting position only) or GES 8/10;WAXWSU-00600-C003The two installation positions (3 modules each) areequipped with:three S250 modulesCAXESM-00100-C001one SC duplex moduleLAXLSM-00208-C001and one blank coverWAXWSM-00108-C001144 Corning Cable Systems


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Mounting Panels for Ackermann Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00600-C003 Mounting Panel for Ackermann 1/1Floor Boxes GES 2, GES 4, GES 4/10,GESR 4, GES 6, GES 6/10, GESR 7/10(outer mounting position only)or GES 8/10, for the installation of6 LANscape modules, with integratedstrain relief and six cable ties,designation window, metal, blackFutureCom F IntroductionFutureCom 10 TENFutureCom EWAXWSU-00900-C003 Mounting Panel for Ackerman 1/1Floor Boxes GESR 7/10 (middlemounting position only), GES 9or GESR 9, for the installation of9 LANscape modules, with integratedstrain relief and nine cable ties,designation window, metal, blackFutureCom DFutureCom UEFutureCom UDMounting Panels for VanGeel Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00900-C005 Mounting Panel for VanGeel Floor Box 1/1(IK-1 long), for the installation of9 LANscape modules, withintegrated cable strain reliefand nine cable ties,designation window, metal, blackHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableCorning Cable Systems145


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Mounting Panels for Kleinhuis Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00900-C002 Mounting Panel for Kleinhuis 1/1Floor Box GR. II or GR. III(outer mounting positiononly in the round box),for the installation of 9 LANscape®modules, with integrated cablestrain relief and nine cable ties,designation window, metal, blackMounting Panels for Electraplan Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00900-C004 Mounting Panel for Electraplan 1/1Floor Box KDR Q3 and KDR R3(left, center, right), for theinstallation of 9 LANscape modules,with integrated cable strain reliefand nine cable ties,designation window, metal, blackMounting Panels for Vergokan Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00900-C006 Mounting Panel for Vergokan 1/1Floor Box KDSVV (left, center, right),for the installation of 9 LANscapemodules, with integrated cablestrain relief and nine cable ties,designation window, metal, black146 Corning Cable Systems


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Mounting Panels for OBO Bettermann Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00900-C007 Mounting Panel for OBO Bettermann 1/1Floor Boxes GE 12 R/5,GE 12R/10,GE 12 RK/5,GE 12RK/10, (left, center,right), for the installation of9 LANscape® modules, withintegrated cable strain reliefand nine cable ties,designation window, metal, blackFutureCom F IntroductionFutureCom 10 TENFutureCom EProtection Boxes for Mounting PanelsUnits perOrder Number Description DeliveryWAXWSU-00000-C003 Protection Box for Ackermann 1/1Floor Boxes (GES 2, GES 4,GES 4/10, GESR4, GES 6, GES 6/10,GESR 7/10 (only outer mountingposition) or GES 8/10, with integratedcable management, metal, blackFutureCom DFutureCom UEFutureCom UDTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>HardwareWAXWSU-00000-C004 Protection Box for Ackermann 1/1Floor Boxes GESR 7/10 (only centerposition), GES 9 or GESR 9, KleinhuisGr. II or Gr. III (only outer mountingposition in round boxes), ElektroplanKDR Q3 or KDR R3 (left, center, right),VanGeel (IK-1 long), Vergokan KDSVV(left, center, right) and OBO BettermannGE12 R1S, GE 12 R/10, GE 12 RK/5 orGE 12 RK/10 (left, center, right),with integrated cable management,metal, blackCorning Cable Systems147


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Protection Boxes for Mounting PanelsUnits perOrder Number Description DeliveryWAXLSU-00000-C005 Splice Tray for Protection Box 1/1WAXWSU-00000-C003(Ackermann GES 2, GES 4, GES 4/10,GESR 4, GES 6, GES 6/10, GESR 7/10,outer mounting position only, orGES 8/10), with splice organizer forthe storage of 12 crimp-spliceprotectors, metal, blackWAXLSU-00000-C006 Splice Tray for Protection Box 1/1WAXWSU-00000-C004 for AckermannFloor Boxes GESR 7/10 (only center position),GES 9 or GESR 9, Kleinhuis Gr. II or Gr. III(only outer mounting position in roundboxes), Elektroplan KDR Q3 or KDR R3(left, center, right), VanGeel (IK-1 long),Vergokan KDSVV (left, center, right) andOBO Bettermann GE12 R1S, GE 12 R/10,GE 12 RK/5 or GE 12 RK/10 (left, center, right),with splice organizer for the storage of12 crimp-splice protectors, metal, blackMounting Panels for Ackermann Floor BoxesFeaturesSuitable for all LANscape fiber optic or copper modulesMetal construction, high-grade steelNo mounting insert requiredUnits perOrder Number Description DeliveryWAXWSU-00100-C001 Mounting Panel for Ackermann 1/1Floor Boxes GESR 2, for theinstallation of one LANscapemodule, with grounding flap,metal, high-grade steel148 Corning Cable Systems


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Mounting Panels for Ackermann Floor BoxesUnits perOrder Number Description DeliveryWAXWSU-00600-C004 Mounting Panel for Ackermann 1/1Floor BoxGES 2,GES 4, GES 4/10,GESR 4, GES 6, Ges6/10, GES7/10(outside) or GES 8/10 for theinstallation of 6 LANscape® modules,high-grade steelFutureCom F IntroductionFutureCom 10 TENFutureCom EWAXWSU-00900-C001 Mounting Panel for Ackermann 1/1Floor Box GESR 7/10 (center), GES 9,or GESR 9, for the installation of9 LANscape modules,high-grade steelFurther<strong>Information</strong>FutureCom DFutureCom UEIndustrialCableFutureCom UDInstallation OptionHardwareMounting panel for Ackermann floor box GESR 2WAXWSU-00100-C001equipped with one S1200 moduleCAXFSM-00100-C001in conjunction with an adapter frameCAXFSN-00110-C001Telephone /ISDN ProductsFlex Wire Cablefor Patch CordMounting in the Ackermann Floor Box GESR 2SpecialCableCorning Cable Systems149


Accessories for Floor Box SolutionsFeaturesSuitable for all LANscape® modules in conjunction withuniversal module housings (WAXWSE-V0201-C002)Robust metal constructionNo mounting insert requiredIntegrated cable strain reliefRapid installation by snapping the module housings intothe mounting panelNo screws required<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSU-00400-C001 Mounting Panel for Ackermann 1/1Floor Boxes GES 2, GES 4, GES 4/10,GESR 4, GES 6, GES 6/10, GESR 7/10(only center position) or GES 8/10for the installation of 2 LANscapehousings (WAXWSE-V0201-C002 orCAXCSE-V0201-C001),high-grade steelWAXWSU-00600-C001 Mounting Panel for Ackermann 1/1Floor Boxes GESR 7/10 (center),GES 9, or GESR 9, for the installationof 3 LANscape Housings(WAXWSE-V0201-C002 orCAXCSE-V0201-C001),high-grade steelWAXWSU-00600-C002 Mounting Panel for Kleinhuis 1/1Floor Box GR.II and GR.III (outsidemounting position in round box),for the installation of 3 LANscapeHousings (WAXWSE-V0201-C002or CAXCSE-V0201-C001),high-grade steel150 Corning Cable Systems


Accessories for Floor Box Solutions<strong>Ordering</strong> <strong>Information</strong>Blank Cover PanelOrder Number Description DeliveryWAXWSU-00000-C001 Blank Cover Panel for unused 1/1mounting positions, suitablefor Ackermann and Kleinhuismounting panels (page 150),metal, high-grade steelFutureCom F IntroductionFutureCom 10 TENFutureCom EInstallation OptionsMounting panel in the Kleinhuis floor box GR. IIIWAXWSU-00600-C002FutureCom DFutureCom UEThe three installation positions are configured as follows:1. Blank CoverWAXWSU-00000-C0012. Module housings with self-closing shuttersCAXCSE-V0201-C001equipped with two S100 eL modulesCAXGSM-00100-C001and one green S/FTP flex/26 patch cordCCAEGB-G4002-A030-C03. Universal HousingWAXWSE-V0201-C002equipped with one S100 eL moduleCAXGSM-00100-C001and one gray S/FTP flex/26 patch cordCCAEGB-G1002-A020-C0and one MT-RJ fiber optic moduleLAXLSM-00101-C004Mounting in the Kleinhuis Floor Box GR. IIIFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems151


Patch Panels and Patch Panel Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSV-02400-C001 19“ Patch Panel, 1/1for max. 24 LANscape®fiber optic or FutureComcopper modules, withintegrated cable strainrelief, 1 U,high-grade steelWAXWSV-02400-C002 19“ Patch Panel, 1/1for max. 24 LANscapefiber optic or FutureComcopper modules, 1 U,high-grade steelWAXWSV-01200-C001 10“ Patch Panel, 1/1for max. 12 LANscapefiber optic or FutureComcopper modules, withintegrated cable strainrelief, 1 U,high-grade steelWAXWSV-04800-C001 19“ Patch Panel, 1/1for max. 48 LANscapefiber optic or FutureComcopper modules, withintegrated cable strainrelief,3 U,high-grade steel152 Corning Cable Systems


Patch Panels and Patch Panel Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description Delivery19“ Blank Panel,to fill unused areasin the distribution cabinetor rack,high-grade steelWAXWSW-00000-C004 1 U 1/1WAXWSW-00000-C005 2U 1/1FutureCom F IntroductionFutureCom 10 TENFutureCom UEFutureCom UDFlex Wire Cablefor Patch CordFurther<strong>Information</strong>IndustrialCableSpecialCableTelephone /ISDN ProductsHardwareFutureCom DFutureCom EWAXWSW-00000-C007 19“ Cable Management 1/1Panel, 1 U, high-grade steelfront panel with 5 blackcable managementbracketsWAXWSW-00000-C008 19“ Cable Feedthough 1/1Panel, for feeding thecables into the cabinetinterior or rack, incl. edgegrommeting, high-gradesteel front panelCorning Cable Systems153


Patch Panels and Patch Panel Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSV-02408-C001 19“ Patch Panel, 1/1for max. 24 LANscape®fiber optic or FutureComcopper modules, withintegrated cable strainrelief, 1 U,blackWAXWSV-02408-C002 19“ Patch Panel, 1/1for max. 24 LANscapefiber optic or FutureComcopper modules, 1 U,black154 Corning Cable Systems


Patch Panels and Patch Panel Accessories<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description Delivery19“ Blank Panel,to fill unused areasin the distributioncabinet or rack,blackWAXWSW-00008-C004 1 U 1/1WAXWSW-00008-C005 2U 1/1FutureCom F IntroductionFutureCom 10 TENFutureCom UEFutureCom UDFlex Wire Cablefor Patch CordFurther<strong>Information</strong>IndustrialCableSpecialCableTelephone /ISDN ProductsHardwareFutureCom DFutureCom EWAXWSW-00008-C007 19“ Cable Management 1/1Panel,1 U, blackfront panel with 5 blackcable managementbracketsWAXWSW-00008-C008 19“ Cable Feedthough 1/1Panel, for feeding thecables into the cabinetinterior or rack, incl. edgegrommeting, blackfront panelCorning Cable Systems155


Patch Panels and Patch Panel Accessories<strong>Ordering</strong> <strong>Information</strong>Designation Labels for Patch PanelsOrder Number Description DeliveryWAXWSW-00000-C002 440 mm Designation Window, 1/1self-adhesive for LANscape®patch panelsWAXWSW-00000-C003 DIN A4 Designation Label Sheet, 1/1with 20 title stripsfor LANscape patch panels, whiteDust Protection PlugUnits perOrder Number Description DeliveryTKE:1304010 Dust Protection Plug for 1/100RJ45 Modules, gray156 Corning Cable Systems


Consolidation Point Housings for LANscape® ModulesFeaturesFull metal housing for up to 12 LANscape® fiber opticor copper modulesConforms to standards ISO/IEC 11801 (2002) andEN 50173-1 (2003)Ideally suited for a distribution or consolidation pointSuitable for ceiling, wall, false floor or desk mountingIndividual strain relief for incoming and outgoing cablesDust-proof feedthrough for incoming cablesEasy plug-in of consolidation point cables (dust protectionand mechanical protection)Housing floor electrically conductive for optimalshielding transition or groundingInstallation height of 60 mmFastening of the housing top with non-detachable screwsBlack sheet steel housing top, RAL 9005, white labelingFutureCom D FutureCom E FutureCom 10 TEN FutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryWAXWSW-00008-C015 Consolidation Point 1/1Housing for max.12 LANscape modules,with cable strain relieffor incoming datacable, patch cord strainrelief and dust protectionflap for floor, wall andceiling mounting,60 x 263 x 320 mm(HxWxD)FutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCableCorning Cable Systems157


Tools and AccessoriesDescriptionThe installation of FutureCom modules is even easier andquicker with special tools. These high-quality tools areavailable together in a practical toolkit, as well asindividually. The use of parallel pliers to terminate theIDC-contacts of the FutureCom F S1200 modules is stronglyrecommended (see page 160).<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSN-00000-C005 Assembly Toolkit for FutureCom Modules 1/11 2 34 5 6 7 8 9 10 11 121314 15158 Corning Cable Systems


Tools and AccessoriesAssembly Toolkit ContentsDescription1. Crimping Tool2. Module Tool3. S1200 Installation Tool4. Screwdriver for Slotted Screws, Size 45. Screwdriver for Cross Slotted Screws, Size 16. Edge-cutter7. Electronics Edge-Cutter, 125 mm8. Waterproof Pen, white9. Waterproof Pen, black10. Telephone Scissors, 130 mm11. Open-Ended Wrench, size 8 x 1012. Tape Measure, 1.4 m long13. Copper Conducting Tape, 12.7 mm wide,16.5 m14. Steel Ruler, 300 mm long15. “Jokari” Stripping Knife16. Installation Instructions<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSN-00000-C004 Copper Conducting Tape, 12.7 mm wide, 1/116.5 mApplicationAssembly of additional cable strain relief for S100 e , S100 eL and S250 ModulesAssembly of the basic modules with wire managementfor S10 TEN , S100 e , S100 eL and S250 ModulesTool for stripping cable, trimming PiMF foil and preparing the pairs of S1200modules or connectorsUniversalUniversalUniversalUniversalMarkingMarkingUniversalHexagon head bolts/nuts, size 8 x 10UniversalModule installation (terminating braid shield)UniversalCutting cable sheathAssembly of S1200/S250/S250 fx /U250/U250 fx /S100 eL /S100 e /U100 e ModulesFutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordCorning Cable Systems159


Tools and Accessories<strong>Ordering</strong> <strong>Information</strong>Parallel Pliers for S1200 Module AssemblyUnits perOrder Number Description DeliveryCAXCSN-00000-C008 Comfort Wide-Jawed Parallel Pliers, 1/1for terminating IDC contacts onFutureCom S1200 ModulesS1200 Assembly ToolCAXFSN-00000-C001 S1200 Assembly Tool, for S1200 modules 1/1and S1200/4- or S1200/2 connectors160 Corning Cable Systems


Tools and Accessories<strong>Ordering</strong> <strong>Information</strong>Assembly Tool for ModulesUnits perOrder Number Description DeliveryCAXCSN-00000-C007 Assembly Tool, 1/1for connectingthe basic moduleswith the wiremanagement forFutureCom S10 TEN ,S10 TEN fx , S250,S250 fx ,U250, U250 fx , S100 eL ,S100 e , U100 e modulesFurther<strong>Information</strong>SpecialCableFutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom UDHardwareTelephone /ISDN ProductsIndustrialCableFlex Wire Cablefor Patch CordFutureCom UEFutureCom DCrimping Pliers for Additional Strain ReliefUnits perOrder Number Description DeliveryCAXCSN-00000-C002 Crimping Pliers for die assembly 1/1of the additional cable strain relieffor the FutureCom S10 TEN ,S10 TEN fx ,S250,S250 fx , U250, U250 fx , S100 eL ,S100 e , U100 e modulesCorning Cable Systems161


IDC Terminal Strips 1000 RTDescriptionFeaturesCorning Cable Systems IDC terminal strips provide a reliableand effective wire connection for telecommunications anddata networks at very high density. Our strips can be mountedin 19“ panels or IDC blocks, for direct connectorization,with punch down tool. The IDC terminal strips offer a veryhigh density with a height of only 13.8 mm including wireguides. They are easy to install and maintain. Userfriendlycable management supports longterm control over changingjumpering.High densityUser-friendly cable managment through wire guidesHigh felxibility due to adaptability of different wireguidesMultiple access wire guiding of incoming wires(e.g. system cable to be terminated on upper row of IDCcontacts) is possible from either rear or left or right handside.Multiple access wire guiding of outgoing wires (to beterminated on lower row of IDC contacts) is possiblefrom either left or right hand sideAll combinations possible and available on requestSuitable for conductor size AWG 22-28<strong>Ordering</strong> <strong>Information</strong>IDC Disconnection Terminal StripsUnits perOrder Number Description DeliveryCable side from the right,jumper side from the leftC39104-A123-A10 numbered, white 10 pairsC39104-A123-A11 numbered, white 10 pairsC39104-A123-A12 numbered, white 10 pairsC39104-A123-A13 numbered, white 10 pairsIDC Switching Terminal StripsC39104-A123-A40 numbered, blue 10 pairsC39104-A123-A41 numbered, blue 10 pairsC39104-A123-A42 numbered, blue 10 pairsC39104-A123-A43 numbered, blue 10 pairsIDC Terminal Strip 1000RT19“ Rack162 Corning Cable Systems


IDC Terminal Strips 1000RT<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description Delivery19“ SolutionsC39393-A80-D53 Horizontal 19“ Rack (empty) for Series 1000RT IDC terminal strips, 1IDC terminal strips ordered separately (max. 28 terminal strips; 280 pairs)C39393-A80-D52 Horizontal 19“ bracket to install Series 1000RT mounting frames, 12 pcs. required, mounting frames and IDC terminal strips orderedseparatelyC39104-A123-B69 20-way mounting frames with closed jumper comb (length = 321 mm), 14 pcs. required to install 20 terminal strips* different sizes of mounting and full cablinet frames also availableOvervoltage / Overcurrent Terminal Strips ProtectionS30264-D1006-S210 Overvoltage (3-point) 230 V + 20 %, with fail safe 1S30264-D1006-S211 Overvoltage / Overcurrent (5-Point), 230 V + 20 %, with fail safe, 150 mA / PTC 1* single pair protector also availableTerminal Strips PatchcordsC39195-A332-A12 Patch cord 1 x 1000RT to 1 x 1000RT, 2 meters 1C39195-A332-A31 Patch cord 1 x 1000RT to 1 x RJ45, 2 meters 1C39195-A332-A30 Patch cord 2 x 1000RT to 1 x RJ45, 2 meters 1Disconnection & Blind Plugs, Tools and LabelingC39334-A117-A3 Disconnection plug for 1 wire, color brown 1C39334-A117-A7 Blind plug for 1 wire, color red 1Marking AccessoriesC39104-A115-C50 Color black 10 capsC39104-A115-C51 Color white 10 capsC39104-A115-C52 Color gray 10 capsC39104-A115-C53 Color red 10 capsC39104-A115-C54 Color green 10 capsC39104-A115-C55 Color blue 10 capsC39104-A115-C56 Color yellow 10 capsC39104-A115-C57 Color purple 10 capsTermination ToolsC39407-A139-A12 Termination Tool for connecting the wires, cutting device with lock for 1optional cutting of excess wire length and extraction hook for removing wiresC39407-A149-A15 Extraction Tool for removing modules out of extremely narrow distribution 1enclosuresFutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableLabeling KitsC39104-A123-D1 100 pairs, 1 ...100 10 pairsC39104-A123-D7 200 pairs, 1 ...200 10 pairsFurther<strong>Information</strong>Corning Cable Systems163


164 Corning Cable Systems


Table of contents9 Telephone / ISDN Products9.1. Cat. 3 / ISDN Telephone Patch Panels 1669.2. Telephone Patch Cords 168Further<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom F IntroductionFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENCorning Cable Systems165


Cat. 3/ISDN Patch Panels and Telephone Patch CordsFeatures19“ patch panel 1U with 50 unshielded 8-pin RJ 45 jacksWire connection via 4-pin LSA/110 connect dual cuttingclamps for AWG 22-26Wiring according to ISO/IEC 11801/EN 50173-1,configuration: Pin 3/6 and Pin 4/5Grounding via M6 screw with nut and lock washer on thepatch panelShield connection directly on the circuit boardIntegrated cable strain relief<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSV-05003-C001 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 50xRJ45,configuration 4.5 and3.6, LSA-PLUS, 1U,light-basic, RAL 7035CAXCSV-05000-C001 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 50xRJ45,configuration 4.5 and3.6, LSA-PLUS, 1U,high-grade steel166 Corning Cable Systems


Cat. 3/ISDN Patch Panels and Telephone Patch CordsFeatures19“ patch panel 1U and 0.5U with 25 unshielded 8-pin RJ 45jacksWire connection via 8-pin LSA/110 connect dual cuttingclamps for AWG 22-26Wiring according to ISO/IEC 11801/EN 50173-1,configuration: Pin 3/6 and Pin 4/5Grounding via M6 screw with nut and lock washer on thepatch panelShield connection directly on the circuit boardIntegrated cable strain reliefFutureCom F IntroductionFutureCom 10 TENFutureCom E<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSV-02503-C001 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 25xRJ45,configuration 4.5 and3.6, LSA-PLUS, 1U,light-basic, RAL 7035FutureCom DFutureCom UEFutureCom UDTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableFurther<strong>Information</strong>SpecialCableHardwareCAXCSV-02500-C001 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 25xRJ45,configuration 4.5 and3.6, LSA-PLUS, 1U,high-grade steelFlex Wire Cablefor Patch CordCorning Cable Systems167


Cat. 3/ISDN Patch Panels and Telephone Patch Cords<strong>Ordering</strong> <strong>Information</strong>Units perOrder Number Description DeliveryCAXCSV-02503-C002 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 25xRJ45,configuration 4.5 and3.6, LSA-PLUS, 0.5U,light-basic, RAL 7035CAXCSV-02500-C002 FutureCom Cat. 3/ISDN 1/1Telephone Patch Panel,unshielded, 25xRJ45,configuration 4.5 and3.6, LSA-PLUS, 0.5U,high-grade steelU/UTP Flex PVC Telephone Patch Cords, ISDN/AnalogOrder Number Description LengthISDN Patch Cord, black, 2xRJ45 Connectors,e.g. for ISDN & analog (So, Upo, U200,U*, U2B1Q, analog a/b, a/b/c/d)CCACOC-A6002-A005-C00.5 mCCACOC-A6002-A010-C01mCCACOC-A6002-A015-C01.5 mCCACOC-A6002-A020-C02 mCCACOC-A6002-A025-C02.5 mCCACOC-A6002-A030-C03mCCACOC-A6002-A040-C04 mCCACOC-A6002-A050-C05 mCCACOC-A6002-A060-C06mCCACOC-A6002-A100-C010 m168 Corning Cable Systems


Table of contents10 Cable for Patch Cords10.1. S/FTP Flex/26 FRNC 17010.2. SF/UTP Flex/26 FRNC 172Further<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems169


FutureCom Patch Cord CableS/FTP flex/26 FRNCApplicationBraided shieldHalogen-free jacket,flame retardantFoil shielding (PiMF)Twisted pairPE foam-skin insulation4 shielded pairsCopper flex wire,AWG 26FutureCom S/FTP flex/26 patch cord cable is designed forapplications up to 600 MHz and its transmission characteristicssatisfy Category 7 specifications.FutureCom patch cord cables are a low-skew product, i.e. theskew between the individual pairs is very low. This is increasinglyrequired for applications above 1 Gigabit. The cable hasa streamlined construction and low weight.Each pair is individually shielded (PiMF). The stranded pairsare additionally braid shielded (S/FTP), which guaranteesoutstanding shielding characteristics. The cable satisfies thestandards of Class B interference radiation (EN 55022), aswell as immunitiy (EN 55024), which enables the realizationof CE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 30 mm>_ 40 mmAWG 26S/FTP flex cable, specified up to 600 MHzOutstanding electrical characteristicsCat.7 flex wire cableLow skew between the pairsSuitable for IDC contacts of RJ45 connectors orS1200 modules/connetorsSurface transfer impedance < 10 m/m at 10 MHzFlame retardant according to IEC 60332-1 , Category BUnprinted170 Corning Cable Systems


FutureCom Patch Cord CableS/FTP flex/26 FRNCElectrical Characteristics (at 20°C)Largest resistance margin2%Insulation resistance>5000 M x kmImpedance Zo at 1 - 100 MHz100 +/- 15%Impedance Zo at 101 - 250 MHz 100 +/- 18%Impedance Zo at 251 - 600 MHz 100 +/- 25%Surface transfer impedance10 m /m(typical value)at 10 MHzOperating capacity43 pF/mPropagation velocity0.78 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHz4.3 ns/mDelay skew4 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom EFrequency in MHz1102031.2562.5100300600FutureCom DAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB2.92.980.096.077.093.080.095.077.092.093.18.57.980.096.077.093.074.093.071.090.088.112.110.880.096.077.093.068.093.065.090.085.215.213.580.096.077.093.064.188.061.185.082.5* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)21.719.575.195.072.592.058.181.055.178.075.527.825.272.494.069.491.054.072.051.069.068.850.044.365.386.062.383.044.560.041.557.041.773.363.560.880.057.877.038.451.035.448.016.5FutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Flex Wire Cablefor Patch CordType designationCategory Pair countFire Load(MJ/m)ZeroHalogenColorOuter(mm)Weight(kg/km)Length(m)Order NumberIndustrialCableS/FTP flex/26S/FTP flex/26S/FTP flex/26S/FTP flex/26S/FTP flex/26S/FTP flex/267777774444440.430.430.430.430.430.43YesYesYesYesYesYesgrayblueyellowgreenredblack5.85.85.85.85.85.8424242424242200020002000200020002000CCXFGB-G0047-0001-L8CCXFGB-G0047-0002-L8CCXFGB-G0047-0003-L8CCXFGB-G0047-0004-L8CCXFGB-G0047-0005-L8CCXFGB-G0047-0006-L8SpecialCableFurther<strong>Information</strong>Corning Cable Systems171


FutureCom Patch Cord CableSF/UTP flex/26 FRNCApplicationBraided shieldHalogen-free jacket,flame retardantFoil shieldTwisted pairPE foam-skin insulation4 shielded pairsCopper flex wire,AWG 26The FutureCom SF/UTP flex/26 patch cord cable isspecified for applications up to 300 MHz and it´s outstandingtransmission characteristics satisfy Channel D (2002)specifications.FutureCom patch cord cables are low-skew products. This isincreasingly required for applications above 1 Gigabit. Thecable has a streamlined construction and low weight.The stranded pairs are foil shielded and have a braidedshield (SF/UTP), which guarantees outstanding shieldingcharacteristics. The cable satisfies the standards for Class Binterference radiation (EN 55022), as well as immunity(EN 55024), which enables the realization of CE-compatiblenetworks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 30 mm>_ 40 mmAWG 26SF/UTP flex cable, specified up to 300 MHzOutstanding electrical characteristicsFull copper braid shieldCat. 5e flex cableLow skew between the pairsSuitable for IDC contacts, RJ45 connectors orS1200 modules/connetorsSurface transfer impedance < 10 m/m at 10 MHzFlame retardant according to IEC 60332-1, Category BUnprinted172 Corning Cable Systems


FutureCom Patch Cord CableSF/UTP flex/26 FRNCElectrical Characteristics (at 20°C)Largest resistance margin3%Insulation resistance>150 M x kmImpedance Zo at 1 - 100 MHz100 +/- 15%Surface transfer impedance10 MHz (NVP x c)Propagation delay >_ 10 MHz4.5 ns/mDelay skew7 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom EFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB13.23.065.370.062.3–63.8–60.8–67.0106.05.856.365.053.3–51.8–48.8–59.2169.59.050.360.047.3–43.8–40.8–51.02013.612.245.852.042.8–37.8–34.8–39.8* Standard: Requirements for Category 5/5e flexible cable (conforms with EN-50288-2-2)31.2517.114.742.948.039.9–33.9–30.9–33.362.524.822.538.445.035.4–27.9–24.9–22.5Hardware FutureCom UD FutureCom UE FutureCom DTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>10032.027.335.345.032.3–23.8–20.8–17.7300–48.3–35.0–––––––<strong>Ordering</strong> <strong>Information</strong>Type designation Category Pair countFire Load(MJ/m)ZeroHalogenColorOuter(mm)Weight(kg/km)Length(m)Order NumberSF/UTP flex/26SF/UTP flex/26SF/UTP flex/26SF/UTP flex/26SF/UTP flex/26SF/UTP flex/265e5e5e5e5e5e4444440.430.430.430.430.430.43YesYesYesYesYesYesgreyblueyellowgreenredblack5.75.75.75.75.75.7404040404040200020002000200020002000CCXDGF-C0047-0001-L8CCXDGF-C0047-0002-L8CCXDGF-C0047-0003-L8CCXDGF-C0047-0004-L8CCXDGF-C0047-0005-L8CCXDGF-C0047-0006-L8Corning Cable Systems173


174 Corning Cable Systems


Table of contents11 Industrial Cable11.1. S/FTP 600/23 PUR Cable 17611.2. SF/UTP J-09YS (ST) CH Cable 17811.3. S/FTP 600 flex/26 PUR Cable 180Further<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems175


FutureCom Industrial CableS/FTP 600/23 PURApplicationBraided shieldPUR sheathTwisted pairFoil shielding (PiMF)PE foam-skininsulationCopper conductorAWG 234 shielded pairsThe FutureCom Industrial S/FTP 600/23 cable withpolyurethane external jacket is particularly suitable forindustrial applications. It is recommended in conjunctionwith FutureCom metal outlets for industrial networks.This cable is specified for applications to up 800 MHz andsatisfies Category 7 specifications ISO/IEC 11801 (2002) andEN 50173-1 (2003).These cables are low-skew products, i.e. the skew betweenthe individual pairs is very low. This is increasingly requiredfor applications above 1 Gigabit. The cable has a streamlinedconstruction and low weight.Each pair is individually shielded (PiMF). The stranded pairsare additionally braid shielded (S/FTP), which guaranteesoutstanding shielding characteristics. The cable satifies thestandard for Class B interference radiation (EN 55022), aswell as immunitiy (EN 55024), which enables the realizationof CE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freeFoam-skin materialPolyurethaneDry anddamp rooms0 to +50°C-20 to +60°C>_ 40 mm>_ 60 mmAWG 23S/FTP 600/23 PUR cable, specified up to 800 MHzOutstanding electrical characteristicsEach pair is shielded (PiMF)Full copper braid shieldStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH)Flame resistant and non-corrosiveLubricant-resistant, microbe-resistant and hydrolysisresistant176 Corning Cable Systems


FutureCom Industrial CableS/FTP 600/23 PURElectrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground1%>5000 M x km125 +/- 20%100 +/- 15%100 +/- 18%100 +/- 25%46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropagation velocity0.79 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew4.2 ns/m4 ns/100 mFrequency in MHzAttenuation in dB/100m*Typical values dB/100mNEXT in dB at 100 m *12.01.780.0105.75.080.0167.26.580.0208.17.380.031.2510.19.280.062.514.513.275.110018.516.972.430033.330.765.360048.944.060.8800–53.0–Typical values in dB at 100m>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 95.0 91.0 87.0PSNEXT in dB at 100 m*Typical values in dB at 100mELFEXT in dB at 100 m*Typical values in dB at 100mPSELFEXT in dB at 100 m*Typical values in dB at 100mACR in dB77.098.080.093.077.091.098.377.098.074.093.071.091.095.077.098.069.993.066.991.093.577.098.068.093.065.091.092.777.098.064.190.061.188.090.872.598.058.186.055.184.086.869.497.054.083.051.081.082.162.393.044.568.041.566.064.357.889.038.451.035.449.047.0–85.0––––34.0* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>IndustrialCableType designationCategory Pair countFire Load(MJ/m)ZeroHalogenMaxTensile Outer Weight LengthStrength (N) (mm) (kg/km) (m)Order NumberSpecialCableIndustrial S/FTP 600/23 74P, PUR40.74Yes1547.7641000CCXIPB-F0047-C001-L7Further<strong>Information</strong>Corning Cable Systems177


FutureCom Industrial 120 CableSF/UTP J-09YS (ST) CHApplicationHalogen-free jacket,flame retardantStar QuadFoil shieldingPP foilThe FutureCom 120 Industrial Cable is designedspecifically for data and voice transmission in industrial ortelecommuncations enviroments. These cables can be usedas connecting cables or for direct installation in dry as wellas damp rooms.Dummy elementBraid shieldAdditional wireFoam-skin insulationCopper conductorAWG 24Mechanical CharacteristicsFeaturesConductor insulationOuter jacketJacket colorInstallation areaTemperature (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorPolypropylenefoam-skin materialHalogen-free, flameretardentYellow (RAL 1021)In dry and damp rooms-5 to +50°C-30 to +70°C>_ 42 mm>_ 60 mmAWG 24Category 3 cable, specified up to 16 MHzCategory 4 cable in a quad, up to 20 MHzComplete shielding with foil and copper braid shieldLow skew between the pairsHalogen-free, LSZH (low smoke, zero halogen)Flame retardant according to IEC 60332-3, Category C178 Corning Cable Systems


FutureCom Industrial 120 CableSF/UTP J-09Ys (ST) CHElectrical Characteristics (at 20°C)Frequency in MHz 0.772 1 4 10 16 20Typical values in dB/100 m 1.5 1.75 3.3 4.9 6.8 7.6Typical values in dB at 100 m, Cable 61.5 58.9 47.2 40.3 36.9 34.7Typical values in dB at 100 m, Quad 66 65.8 53.0 44.3 42.4 41.2FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TENHardwareTelephone /ISDN ProductsFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordFutureCom F IntroductionElectrical Characteristics (at 20°C)Insulation resistance 10 G x kmImpedance Zo at 0.064 MHz120 +/- 15NEXT at 1 MHzEnd to end in the same quad 50 dBEnd to end in different cables (2x60m) 75 dBELFEXT at 1 MHzEnd to end in the same quad 50 dBEnd to end in different cables (2x60m) 75 dBMax. attenuation at 1 MHz 19 dB/1000mShield attenuation (30 to 900 MHz) 80 dBOperating Voltage300 VssTesting Voltage800 Vss(conductor/conductor, conductor/shielding at 50 Hz, 1 min)<strong>Ordering</strong> <strong>Information</strong>Type designationJ-09YS(ST)CH 4x2x0,5 BD 120 Category3Pair count4ZeroHalogenYesOutermm7,5Weight(kg/km)80Length(m)1000Order NumberCCXIEO-A0027-C001-L7Corning Cable Systems179


FutureCom Industrial S/FTP 600flex/26 PUR Cat. 7ApplicationBraided shieldPUR jacketFoil shielding (PiMF)Twisted pairPE foam-skininsulation4 shielded pairsCopper flex wireAWG 26The Industrial S-STP 600 flex cable with polyurethane jacketis specially designed for industrial use. It is specified up to600 MHz and satisfies Category 7 standards, ISO/IEC 11801(2002) and EN 50173-1 (2003).FutureCom cables are low skew products, i.e. the skew betweenthe individual pairs is very low. This is increasinglybeing requested for applications above Gigabit Ethernet.Additional features are the slim design and low weight ofthe cables.Each pair is individually shielded (PiMF). The stranded pairsare additionally sheathed with a braid shield (S/FTP), whichguarantees outstanding shielding characteristics. The cablesatisfies Class B interference radiation standards (EN 55022),as well as immunity (EN 55024), which enables the realizationof CE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-freefoam skin materialHalogen freeFlame retardentIn dry and damp rooms0 to +50°C-20 to +60°C>_ 30 mm>_ 40 mmAWG 26S/FTP 600 flex/26 PUR flex cable,specified up to 600 MHzOutstanding electrical characteristicsEach pair is foil-shielded (PiMF)Full copper braid shieldStreamlined designLightweightLow skew between the pairsHalogen-free (LSZH)Flame resistant and non-corrosiveLubricant-, microbe- and hydrolysis resistantUnprinted180 Corning Cable Systems


FutureCom Industrial S/FTP 600flex/26 PUR Cat. 7Electrical Characteristics (at 20°C)Largest resistance margin2%Insulation resistance>5000 M x kmImpedance Zo at 1 - 100 MHz 100 +/- 15%Impedance Zo at 101 - 250 MHz 100 +/- 18%Impedance Zo at 251 - 600 MHz 100 +/- 25%Surface transfer impedance 10 MHz 0.78 x cPropagation delay >_ 10 MHz 4.3 ns/mDelay skew4 ns/100 mFutureCom F IntroductionFutureCom 10 TENFutureCom EFrequency in MHzAttenuation in dB/100m*Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m*Typical values in dB at 100mELFEXT in dB at 100 m*Typical values in dB at 100mPSELFEXT in dB at 100 m*Typical values in dB at 100mACR in dB12.92,980.096.077.093.080.095.077.092.093.1108.57.980.096.077.093.074.093.071.090.088.12012.110.880.096.077.093.068.093.065.090.085.231.2515.213.580.096.077.093.064.188.061.185.082.5* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)62.521.719.575.195.072.592.058.181.055.178.075.510027.825.272.494.069.491.054.072.051.069.068.830050.044.365.386.062.383.044.560.041.557.041.760073.363.560.880.057.877.038.451.035.448.016.5Hardware FutureCom UD FutureCom UE FutureCom D<strong>Ordering</strong> <strong>Information</strong>Telephone /ISDN ProductsType designationIndustrial S-STP 600flex/26 4PCategory Pair count7 4Fire Load(MJ/m)0.43ZeroHalogenYesOutermmFlex Wire Cablefor Patch CordFurther<strong>Information</strong>SpecialCableIndustrialCable5.8Weight(kg/km)42Length(m)1333Order NumberCCXIHB-G0047-0007-H2Corning Cable Systems181


182 Corning Cable Systems


Table of contents12 Special Cable12.1. F/UTP 450/23 FRNC Cable 18412.2. Outdoor Cable12.2.1. S/FTP 600/23 with Diffusion Barrier 18612.2.2. F/UTP 300/24 18812.2.2. U/UTP 100/24 19012.3. Hybrid Cable12.3.1. Fiber Blow S/FTP 900 19212.3.2. Fiber Blow S/FTP 600 19412.3.3. S/FTP 600/23 4P + J-VH 4G50 FRNC 19612.4. ViMF Cable12.4.1. Cat. 6 Star Quad S/FTP 600/22 FRNC 19812.4.2. Star Quad U/FTP 300/23 FRNC 20012.4.3. Star Quad U/FTP 300/23 PVC 202FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareCorning Cable Systems183


FutureCom Cat. 6 CableF/UTP 450/23ApplicationHalogen-free jacket,flame retardentFoil shieldingFoil shieldingTwisted pairPE foam-skininsulationAdditional wireCentral cross memberThe FutureCom F/UTP 450/23 cable is designed for applicationsup to 450 MHz and exceeds all the requirements forCategory 6 specifications.FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for applications above 1 Gigabit-Ethernet. Thesecables have a streamlined construction and low weight.The four stranded pairs are foil shielded (F/UTP). The cablesatisfies Class B interference radiation standards (EN 55022)as well as immunity (EN 55024) which enables the realizationof CE-compatible networks.Copper conductorAWG 23Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen-free,foam-skin materialHalogen freeFlame retardentIn dry and damp rooms0 to +50°C-20 to +60°C>_ 40 mm>_ 60 mmAWG 23F/UTP 450/23 cable, specified up to 450 MHzOutstanding electrical characteristicsTwisted pairs with 2 foil shieldsLow skew between the pairsHalogen-freeFlame retardant according to IEC 60332-1, Category BNon-corrosive according to IEC 60754-2 and EN 50267Low-smoke according to IEC 61034184 Corning Cable Systems


FutureCom Cat. 6 CableF/UTP 450/23Electrical Characteristics (at 20°C)Frequency in MHzAttenuation in dB/100m per Standard *Near-end crosstalk loss in DB per Standard *PSNEXT in dB at 100 m per Standard *ELFEXT in dB at 100 m per Standard *PSELFEXT in dB at 100 m per Standard *ACR in dB12.166.064.066.064.063.9106.059.357.350.047.053.3167.656.254.245.943.048.6208.554.852.844.041.046.331.2510.751.949.940.137.141.262.515.547.445.434.131.131.910019.944.342.330.027.024.4* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling links (conforms with EN 50288-5-1)25033.038.336.322.019.05.3FutureCom 10 TENFutureCom EFutureCom DFutureCom UEFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom F Introduction<strong>Ordering</strong> <strong>Information</strong>Type designation Category Pair countFire Load(MJ/m)ZeroHalogenMax.TensileStrength(N)OutermmWeight(kg/km)Length(m)Order NumberF/UTP 450/23 4P640.76Yes1046.7491000CCXCDE-B0047-C001-L7Corning Cable Systems185


FutureCom Cat. 7 Outdoor CableS/FTP 600/23 with Diffusion BarrierPE sheathLayered aluminumbandBraided shieldTwisted pairFoil shielding (PiMF)PE foam-skininsulationCopper conductorAWG 23FRNC interior sheath4 shielded pairsApplicationThe FutureCom S/FTP 600/23 data cable with diffusionbarrier is specified up to 800 MHz. It’s transmissioncharacteristics satisfy Category 7 specifications according toISO/IEC 11801 (2002) and EN 50173-1 (2003).FutureCom cables are low-skew products, i.e.the skewbetween the individual pairs is very low. As a result of thealuminum composite layer sheath, this cable is suitable fordirect burial. The cable has a streamlined construction andlow weight.Each pair is individually shielded (PiMF). The stranded pairsare sheathed with a braided shield (S/FTP), which guaranteesoutstanding shielding characteristics. The cable satisfiesthe standard for Class B interference radiation(EN 55022), as well as immunitiy (EN 55024), which enablesthe realization of CE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen free/foam-skin materialHalogen freeOutdoor installation0 to +50°C-20 to +60°C


FutureCom Cat. 7 Outdoor CableS/FTP 600/23 with Diffusion BarrierElectrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground1%> 5000 M x km125 +/- 20%100 +/- 15%100 +/- 18%100 +/- 25%46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropagation velocity0.79 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skew4.2 ns/m4 ns/100 mFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB12.01.780.0>100.077.098.080.093.077.091.098.3105.75.080.0>100.077.098.074.093.071.091.095.0167.26.580.0>100.077.098.069.993.066.991.093.5208.17.380.0>100.077.098.068.093.065.091.092.731.2510.19.280.0>100.077.098.064.190.061.188.090.862.514.513.275.1>100.072.598.058.186.055.184.086.810018.516.972.499.069.497.054.083.051.081.082.130033.330.765.395.062.393.044.568.041.566.064.360048.944.060.891.057.889.038.451.035.449.047.0800–53.0–87.0–85.0––––34.0* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>IndustrialCableType designationCategory Pair countFire Load(MJ/m)ZeroHalogenMaxTensileStrength (N)Outer(mm)Weight(kg/km)Length(m)Order NumberSpecialCableS/FTP 600/23 4P742.98Yes40011.7126Further<strong>Information</strong>1000CCXSDB-F0047-C001-L7Corning Cable Systems187


FutureCom Cat. 5e Outdoor CableF/UTP 300/24 PEColor CodingPair 1Pair 2Pair 3Pair 4Foil shieldingPE-outer sheath2 wires stranded to apairFoil shieldingAdditional wirePE foam-skin PEinsulationCopper conductorAWG 244 shielded pairsWhite with blue rings/blueWhite with orange rings/orangeWhite with green rings/greenWhite with brown rings/brownApplicationThe FutureCom F/UTP 300/24 PE cable is designed for outdoorapplications up to 300 MHz and provides transmissionperformance exceeding Category 5e ISO/IEC 11801 (2002)and EN 50173-1 (2003) specifications.The improved operating temperature of up to -60°C isappropriate for the use under most adverse conditions.This cables are low skew products, i.e. the difference in propagationdelay between the individual pairs isvery low. This is increasingly being requested for GigabitEthernet. The cable as a streamlined construction and lowweight.The stranded pairs are surrounded by foils (F/UTP).The cable satisfies Class B interference radiation(EN 55022), as well as immunity (EN 55024), which enablesthe realization of CE-compatible networks.Mechanical CharacteristicsFeaturesWire insulationSheath materialArea/range of applicationTemperature range (in motion)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radiusduring installationDiameter of the copper conductorHalogen freePE foam-skin materialPEOutdoor installation0 to +50°C-60 to +60°C>35 mm>50 mmAWG 24F/UTP 300/24 PE cable, specified up to 300 MHzOutdoor cable specified up to -60°CExcellent electrical characteristicsFull shielding including 2 foils with additional tinnedcopper wireSlim designLightweightLow skew between the pairsPE jacket188 Corning Cable Systems


FutureCom Cat. 5e Outdoor CableF/UTP 300/24 PEElectrical Characteristics (at 20°C)Largest resistance margin2%Insulation resistance>5000 M x kmDC resistance185 /kmImpedance Zo at 1 - 100 MHz100 +/- 15%Surface transfer impedance46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropogation velocity0.74 * cat >10 MHz (NVP * c)Signal delay >10 MHz4.5 ns/mDelay margin7 ns/100 mFutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFrequency in MHzAttenuation in dB/100m according to standard*Typical values dB/100mNEXT in dB at 100 m to standard*Typical values in dB at 100mPSNEXT in dB at 100 m according to standard*Typical values in dB at 100mELFEXT in dB at 100 m according to standard*Typical values in dB at 100mPSELFEXT in dB at 100 m according to standard*Typical values in dB at 100mACR in dB12.12.065.377.062.375.063.872.060.870.074.9106.35.650.362.047.360.043.860.040.858.055.9168.07.247.359.044.257.039.754.036.752.051.4209.08.045.857.042.855.037.852.034.850.048.531.2511.410.142.954.039.952.033.948.030.946.043.562.516.514.438.450.035.448.027.940.024.938.034.910021.318.235.346.032.344.023.834.020.832.026.7250–29.5–38.5–36.5–22.1–20.17.0300–32.2–35.0–33.0–17.0–15.00.9* Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-2-1)FutureCom UEFutureCom UDHardwareTelephone /ISDN Products<strong>Ordering</strong> <strong>Information</strong>Type designation Category Pair countZeroHalogenMin. TemperatureMaxTensileStrength (N)Outer(mm)Weight(kg/km)Std.Length(m)Order NumberFlex Wire Cablefor Patch CordIndustrialCableF/UTP 300/24 PE5e4No-60°C826,2361000CCXDAE-C0047-C001-L7SpecialCableFurther<strong>Information</strong>Corning Cable Systems189


FutureCom Cat. 5e Outdoor CableU/UTP 100/24 PEColor CodingPair 1Pair 2Pair 3Pair 4PE-outer jacket2 wires stranded to apairPE foam-skin PEinsulation4 unshielded pairsCopper conductorAWG 24White with blue rings/blueWhite with orange rings/orangeWhite with green rings/greenWhite with brown rings/brownApplicationThe FutureCom U/UTP 100/24 PE cables are designed foroutdoor applications up to 100 MHz and provides transmissionperformance exceeding Category 5e ISO/IEC 11801(2002) and EN 50173-1 (2003) specifications. The improvedoperating temperature of up to -60°C/-40°C is appropriatefor the employment under most, even adverse, conditions.This cables are low skew products, i.e. the difference in propagationdelay between the individual pairs is very low. Thisis increasingly being requested for e.g. Gigabit Ethernet.The cable has a streamlined construction and low weight.The cable satisfies Class B interference radiation (EN 55022),as well as immunity (EN 55024), which enables therealization of CE-compatible networks.Mechanical CharacteristicsFeaturesWire insulationSheath materialArea/range of applicationTemperature range (in motion)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radiusduring installationDiameter of the copper conductorHalogen freePE foam-skin materialPEOutdoor installation0 to +50°C-60 to +60°C>35 mm>50 mmAWG 24U/UTP 100/24 cable , specified up to 100 MHzOutdoor cable specified up to -40°C/-60°CExcellent electrical characteristicsCore and pairs are unshieldedSlim designLightweightLow skew between the pairsPE jacket190 Corning Cable Systems


FutureCom Cat. 5e Outdoor CableU/UTP 100/24 PEElectrical Characteristics (at 20°C)Largest resistance margin3%Insulation resistance>5000 M x kmDC resistance185 /kmImpedance Zo at 1 - 100 MHz100 +/- 15%Mutual capacity45 pF/mPropogation velocity0.74 x cat >10 MHz (NVP * c)Signal delay >10 MHz4.5 ns/mDelay margin7 ns/100 mFutureCom F IntroductionFutureCom 10 TENFrequency in MHzAttenuation in dB/100m according to standard*Typical values dB/100mNEXT in dB at 100 m to standard*Typical values in dB at 100mPSNEXT in dB at 100 m according to standard*Typical values in dB at 100mELFEXT in dB at 100 m according to standard*Typical values in dB at 100mPSELFEXT in dB at 100 m according to standard*Typical values in dB at 100mACR in dBFutureCom UD FutureCom UE FutureCom D FutureCom EHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableFurther<strong>Information</strong>SpecialCable12.11.965.377.462.374.063.868.060.866.074.1106.35.950,365.547.360.043.849.040.847.056.1168.07.447,362.244.256.039.745.036.743.050.6209.08.445,859.742.854.037.842.034.840.047.631.2511.410.542,957.739.951.033.940.030.938.042.562.516.515.138.449.635.447.027.933.024.931.033.910021.319.335.346.632.344.023.828.020.826.026.7*Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-3-1)<strong>Ordering</strong> <strong>Information</strong>Type designation Category Pair countU/UTP 100/24 PEU/UTP 100/24 PE5e5e44ZeroHalogenNoNoMin. Temperature-40°C-60°CMaxTensileStrength (N)8282Outer(mm)5.45.4Weight(kg/km)2828Std.Length(m)10001000Order NumberCCXUAE-C0047-C001-L7CCXUAE-C0047-C002-L7Corning Cable Systems191


FutureCom Hybrid-CableFiber Blow S/FTP 900/23Braided shieldHalogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductorAWG 23Tube forinsertion of fibersApplicationThe FutureCom S/FTP 900/23 fiber blow is prepared for thesubsequent insertion of up to 12 fibers (single or multimodefibers with 250 µm diameter can be inserted). Future-proofcabling, for example fiber-to-the-desk (FTTD), can be easilyrealized. The integrated copper data cable is specified for applicationsup to 1000 MHz and its transmission characteristicssatisfy Category 7 specifications according to ISO/IEC11801 (2002) and EN 50173-1 (2003).FutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for applications above 1 Gigabit. The cable has astreamlined construction and low weight. Each pair isindividually shielded (PiMF). The stranded pairs are sheathedwith a braided shield (S/FTP), which guarantees outstandingshielding characteristics. The cable satisfies the standardsfor Class B interference radiation (EN 55022), as well asimmunity (EN 55024), which enables the realization ofCE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 100 mm(over flat side*)>_ 100 mm(over flat side*)AWG 23Fiber blow S/FTP 900/23, specified up to 1000 MHzOutstanding electrical characteristicsEach pair is individually shielded with foilFull copper braid shieldLow skew between the pairsPrepared for the subsequent insertion of up to 12 fibersHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034* Max. cabling length of 90 m with 12 x 90° bends for a radius of 100 mm192 Corning Cable Systems


FutureCom Hybrid-CableFiber Blow S/FTP 900/23Electrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground1%>5000 M x km125 +/- 20%100 +/- 15%100 +/- 18%100 +/- 25%46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropagation velocity0.79 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skewFrequency in MHzAttenuation in dB/100m*Typical values dB/100mNEXT in dB 100 m *4.2 ns/m4 ns/100 m12.01.780.0105.75.080.0167.26.580.0208.17.380.031.2510.19.280.062.514.513.275.110018.516.872.430033.330.065.360048.942.560.8900–55.0–1000–59.0–Typical values in dB at 100m>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 92.0 86.0 83.0PSNEXT in dB at 100 m*Typical values in dB at 100mELFEXT in dB at 100 m*Typical values in dB at 100mPSELFEXT in dB at 100 m*Typical values in dB at 100mACR in dB77.098.080.093.077.091.098.377.098.074.093.071.091.095.077.098.069.993.066.991.093.577.098.068.093.065.091.092.777.098.064.190.061.188.090.872.598.058.186.055.184.086.869.498.054.083.051.081.083.262.394.044.568.041.566.066.057.890.038.451.035.449.049.5–84.0––––31.0–81.0––––24.0* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)FutureCom F IntroductionFutureCom 10 TENIndustrialCableFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>Type designation Category Pair countS/FTP 900/23 4PFiber Blow7 4Fire Load(MJ/m)0.6ZeroHalogenYesMaxTensile Outer Weight LengthStrength (N)(mm)(kg/km)(m)Order Number1547.5x16118500SpecialCableFurther<strong>Information</strong>WCXWDW-I0047-C001-L6Corning Cable Systems193


FutureCom Hybrid-CableFiber Blow S/FTP 600/23ApplicationBraided shieldHalogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsThe FutureCom S/FTP 600/23 fiber blow is prepared for thesubsequent insertion of up to 12 fibers (single or multimodefibers with 250 µm diameter can be inserted). Future-proofcabling, for example fiber-to-the-desk (FTTD), can be easilyrealized. The integrated copper data cable is specified for applicationsup to 800 MHz and its transmission characteristicssatisfy Category 7 specifications according to ISO/IEC11801 (2002) and EN 50173-1 (2003).PE foam-skin insulationCopper conductorAWG 23Tube forinsertion of fibersFutureCom cables are low-skew products, i.e. the skewbetween the individual pairs is very low. This is increasinglyrequired for applications above 1 Gigabit. The cable has astreamlined construction and low weight. Each pair is individuallyshielded (PiMF). The stranded pairs are sheathedwith a braided shield (S/FTP), which guarantees outstandingshielding characteristics. The cable satisfies the standardsfor Class B interference radiation (EN 55022), as well asimmunity (EN 55024), which enables the realization ofCE-compatible networks.Mechanical CharacteristicsFeaturesConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 100 mm(over flat side*)>_ 100 mm(over flat side*)AWG 23Fiber blow S/FTP 600/23 cable, specified up to 800 MHzOutstanding electrical characteristicsEach pair is individually shielded with foilFull copper braid shieldLow skew between the pairsPrepared for the subsequent insertion of up to 12 fibersHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034* Max. cabling length of 90 m with 12 x 90° bends withregard to a radius of 100 mm194 Corning Cable Systems


FutureCom Hybrid-CableFiber Blow S/FTP 600Electrical Characteristics (at 20°C)Largest resistance marginInsulation resistanceImpedance Zo at 0.064 MHzImpedance Zo at 1 - 100 MHzImpedance Zo at 101 - 250 MHzImpedance Zo at 251 - 600 MHzSurface transfer impedanceUnbalance to ground1%>5000 M x km125 +/- 20%100 +/- 15%100 +/- 18%100 +/- 25%46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropagation velocity0.79 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHzDelay skewFrequency in MHzAttenuation in dB/100m *Typical values dB/100mNEXT in dB 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m *Typical values in dB at 100mACR in dB4.2 ns/m4 ns/100 m12.01.780.0>100.077.098.080.093.077.091.098.3105.75.080.0>100.077.098.074.093.071.091.095.0167.26.580.0>100.077.098.069.993.066.991.093.5208.17.380.0>100.077.098.068.093.065.091.092.731.2510.19.280.0>100.077.098.064.190.061.188.090.862.514.513.275.1>100.072.598.058.186.055.184.086.810018.516.872.4>100.069.498.054.083.051.081.083.230033.330.065.396.062.394.044.568.041.566.066.060048.942.560.892.057.890.038.451.035.449.049.5800–53.0–87.0–85.0––––34.0* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>IndustrialCableType designationCategory Pair countFire Load(MJ/m)ZeroHalogenMaxTensile OuterWeightLengthStrength (N) (mm) (kg/km) (m) Order NumberSpecialCableS/FTP 600/23 4PFiber Blow740.6Yes1547.5x16118500WCXWDW-F0047-C001-L6Further<strong>Information</strong>Corning Cable Systems195


FutureCom Hybrid CableS/FTP 600/23 4P + J-VH 4G50 FRNCBraided shieldHalogen-free jacket,flame retardantTwisted pairFoil shielding (PiMF)4 shielded pairsPE foam-skin insulationCopper conductor AWG 23Halogen-free jacket,flame retardantRip-cord900 µm tight buffered fiberFiberStrain relief(aramide yarn)ApplicationLANscape® Hybrid cables enable the simultaneous installationof a fiber optic and copper data cable.Corning fiber optic multifiber interior cables (MIC) are particularlysuitable for installation into cable conduits or ducts(both vertically and horizontally), false floors, as jumpers oradapter cables and for connecting workstations inside buildings(FTTD - Fiber-to-the-Desk). They can also be used as inter-buildingconnecting cables in dry conduits. The 900µmtight-buffer design allows easy and direct field connectorization.The FutureCom S/FTP 600/23 copper cable is specified forapplications up to 800 MHz and its transmission characteristicssatisfy Category 7 specifications according to ISO/IEC11801 (2002) and EN 50173-1 (2003). A high level of systemperformance for the complete channel is achieved by usingthis high-quality Category 7 cable.FeaturesFiber Optic CableThe low skew between the pairs emphasizes their suitabilityfor applications above 1 Gigabit Ethernet. Due to its outstandingshielding characteristics, the cable satisfies thestandards for Class B interference radiation (EN 55022), aswell as immunity (EN 55024), which enables the realizationof CE-compatible networks.Copper CableFO cable with 900µm tight-buffered fibers,TB-3 construction enables easy, consistent strippingParticularly suitable for field-installable UniCam®connectorsTelecordia color-codingCompletely dry constructionS/FTP 600/23 cable, specified up to 800 MHzOutstanding electrical characteristicsEach pair is individually shielded with foilFull copper braid shieldLow skew between the pairsHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034196 Corning Cable Systems


FutureCom Hybrid CableS/FTP 600/23 4P + J-VH 4G50 FRNCFiber Specification - Laser-Optimized InfiniCor® Multimode FibersFiber TypeFeaturesInfiniCor® OM2 (50 µm)Typ. attenuationLoose TubeCablesTyp. attenuationin the tight buffercable in dB/kmGuaranteed minimumdistance at850 nm 1300 nm 850 nm 1300 nm 1 Gbit/s 10 Gbit/s2.5 0.7 2.7 0.8 600 m 100 mFutureCom F IntroductionMechanical CharacteristicsConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C>_ 40 mm (for 2x(4x2...) over flat side)>_ 60 mm (for 2x(4x2...) over flat side)AWG 23Electrical Characteristics (at 20°C)Largest resistance margin 1%Insulation resistance>5000 M x kmImpedance Zo at 0.064 MHz 125 +/- 20%Impedance Zo at 1 - 100 MHz 100 +/- 15%Impedance Zo at 101 - 250 MHz 100 +/- 18%Impedance Zo at 251 - 600 MHz 100 +/- 25%Surface transfer impedance 46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mUnbalance to ground>20 dB at 100 MHzdB/BZL = 100 mPropagation velocity0.79 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHz 4.2 ns/mDelay skew4 ns/100 mFutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TENFrequency in MHzAttenuation in dB/100m*Typical values dB/100mNEXT in dB 100 m *Typical values in dB at 100mPSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100 m * *Typical values in dB at 100mACR in dB12.01.780.0>100.077.098.080.093.077.091.098.3105.75.080.0>100.077.098.074.093.071.091.095.0167.26.580.0>100.077.098.069.993.066.991.093.5208.17.380.0>100.077.098.068.093.065.091.092.731.2510.19.280.0>100.077.098.064.190.061.188.090.862.514.513.275.1>100.072.598.058.186.055.184.086.810018.516.872.4>100.069.498.054.083.051.081.083.230033.330.065.396.062.394.044.568.041.566.066.060048.942.560.892.057.890.038.451.035.449.049.5800–53.0–87.0–85.0––––34.0*Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)HardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCable<strong>Ordering</strong> <strong>Information</strong>Type designationJ-VH 4G50L/125 +S/FTP 600/23 FRNCCategory7Pair/fibercount4/4Fire Load(MJ/m)1.44ZeroHalogenYesMaxTensile Outer Weight LengthStrength (N)(mm)(kg/km) (m) Order Number1547.5x15.5110500WCXWXW-X0087-C001-L6SpecialCableFurther<strong>Information</strong>Corning Cable Systems197


FutureCom ViMF Cat.6 Cable (Star Quad)S/FTP 600/22 FRNCApplicationBraided shieldHalogen-free jacket,flame retardantFoil shielding1 twisted quadThe FutureCom StarQuad ViMF Cable is designed forapplications in industrial and other harsh environments upto 600 MHz. Its transmission characteristics satisfy Category6 specifications according to ISO/IEC 11801 (2002) andEN 50173-1 (2003).FutureCom ViMF Cables are zero-skew products, i.e. theskew between the individual pairs of foursomes is very low.This is increasingly required for applications above 1 GigabitEthernet. The cable has a streamlined construction and lowweight.PE foam-skin insulationCopper conductorAWG 22PP foilStarQuad ViMF Cables are intended for multimedia applications(voice, image and data communications) where cablesharing is an option. Alongside traditional applications(ISDN, Ethernet and Token Ring), the cables are suitable forsystems with high frequency areas, such as TPDDI via copper(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to1000 Base-T.Mechanical CharacteristicsConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms-5 to +50°C-20 to +60°C>_ 26 mm(over flat side*)>_ 40 mm(over flat side*)AWG 22FeaturesS/FTP 600/22 cable, specified up to 600 MHzOutstanding electrical characteristicsEach StarQuad (foursome) is shielded (ViMF)Different color coding of individual foursomesSimultaneous, standard-conforming transmissionof multiple services is possibleVery robust, thus particularly suitable for application inindustrial and other harsh environmentsFull copper braid shieldZero skew between the foursomesHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034198 Corning Cable Systems


FutureCom ViMF Cat.6 Cable (Star Quad)S/FTP 600/22 FRNCElectrical Characteristics (at 20°C)Largest resistance margin 1%Insulation resistance>5000 M x kmImpedance Zo at 0.064 MHz 125 +/- 20%Impedance Zo at 1 - 100 MHz 100 +/- 15%Surface transfer impedance 46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mGreatest possible loop resistance 130 /kmOperating capacity48 pF/mPropagation velocity0.74 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHz 4.9 ns/mDelay skew0 ns/100 mIndustrialCableFutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFutureCom UEFrequency in MHzAttenuation in dB/100 m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 m (pair/pair)Typical values in dB at 100 m (foursome/foursome)PSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100m *Typical values in dB at 100mACR in dB12.11.566.078.690.064.075.666.075.064.073.077.1106.04.959.367.590.057.364.550.065.047.063.062.6167.66.356.264.090.054.261.045.962.043.060.057.7208.57.154.862.090.052.859.044.060.041.058.054.931.2510.89.051.959.090.049.956.040.154.037.152.050.062.515.512.947.454.590.045.451.534.144.031.142.041.610019.916.544.351.890.042.348.830.036.027.034.035.325033.026.938.345.075.036.342.022.017.019.015.018.1600–43.6–38.070.0–35.0–––––* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)FutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>Type designationS/FTP 600/22 ViMFCategory Quad count62Fire Load(MJ/m)0.89ZeroHalogenYesMaxTensileStrength (N)179Outer(mm)5.2x8.3Weight(kg/km)75Length(m)1000SpecialCableFurther<strong>Information</strong>Order NumberCCXSCD-F0027-C001-L7Corning Cable Systems199


FutureCom ViMF Cat. 5 Cable (Star Quad)U/FTP 300/23 FRNCApplicationFoil shieldingHalogen-freejacketFoil shielding1 twistedquadAdditionalwirePE insulationCopperconductorAWG 23PP foilThe FutureCom StarQuad ViMF Cable is designed forapplications in industrial and other harsh environments upto 300 MHz and its transmission characteristics satisfyCategory 5 specifications according to ISO/IEC 11801 (2002)and EN 50173-1 (2003).FutureCom ViMF Cables are zero-skew products. i.e. theskew between the individual pairs of foursomes is very low.This is increasingly required for Gigabit-Ethernet.StarQuad ViMF Cables are intended for multimedia applications(voice, image and data communications) where cablesharing is an option. Alongside traditional applications(ISDN, Ethernet and Token Ring), the cables are suitable forhigh frequency transmission, such as TPDDI via copper(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to1000 Base-T.FeaturesU/FTP 300/23 cable, specified up to 300 MHzOutstanding electrical characteristicsEach StarQuad (foursome) is shielded (ViMF)Simultaneous, standard-conforming transmissionof multiple services is possibleVery robust, thus particularly suitable for application inindustrial and other harsh environmentsFull shielding including one PP foil and 2 aluminum-cladfoilsZero skew between the foursomesHalogen-free (LSZH)Flame retardant according to IEC 60332-3, Category CNon-corrosive according to IEC 60754-2 (FRNC)Low smoke according to IEC 61034Available in 2, 3, 4 and 7 foursomes200 Corning Cable Systems


FutureCom ViMF Cat. 5 Cable (Star Quad)U/FTP 300/23 FRNCMechanical CharacteristicsConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C2V: >_ 30 mm (flat side)3V: >_ 50 mm4V: >_ 52 mm7V:>_ 65 mm2V: >_ 45 mm (flat side)3V:>_ 75 mm4V: >_ 78 mm7V: >_ 100 mmAWG 23Electrical Characteristics (at 20°C)Largest resistance margin2%Insulation resistance>5000 M x kmImpedance Zo at 0.064 MHz125 +/- 20%Impedance Zo at 1 - 100 MHz 100 +/- 15%Surface transfer impedance46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mGreatest possible loop resistance 130 /kmOperating capacity48 pF/mPropagation velocity0.68 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHz4.9 ns/mDelay skew0 ns/100 mFutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFrequency in MHzAttenuation in dB/100 m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 m (pair/pair)Typical values in dB at 100 m (foursome/foursome)PSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m according *Typical values in dB at 100mPSELFEXT in dB at 100m according *Typical values in dB at 100mACR in dB12.11.865.380.090.062.376.763.875.060.873.078.2106.35.250.364.090.047.361.143.864.040.862.058.8168.06.747.261.090.044.257.839.761.036.759.054.3209.07.545.860.090.042.856.937.859.034.857.052.531.2511.49.442.956.090.039.952.833.953.030.951.046.662.516.513.738.450.590.035.447.527.947.024.945.036.810021.317.635.347.090.032.344.023.843.020.841.029.4200–25.1–41.080.0–38.0–32.0–30.015.9300–30.938.380.0–35.3–22.0–20.07.4*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)FutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>IndustrialCableType designationFire Load ZeroCategory Quad count (MJ/m) HalogenMaxTensileStrength (N)Outer(mm)Weight(kg/km)Length(m)Order NumberSpecialCableU/FTP 300/23 2VU/FTP 300/23 3VU/FTP 300/23 4VU/FTP 300/23 7V555523470.891.711.953.28YesYesYesYes1101652203905.6x9.610.110.413.27910512521910005005001000CCXSDC-C0022-C001-L7CCXSDC-C0032-C001-L6CCXSDC-C0042-C001-L6CCXSDC-C0072-C001-L7Further<strong>Information</strong>Corning Cable Systems201


FutureCom ViMF Cat. 5 Cable (Star Quad)U/FTP 300/23 PVCSchirmfolieFoil shieldingMantel PVC jacket PVCSchirmfolieFoil shieldingBeidraht Additional wire41 Adern twisted zum quad Vierer verseiltPE insulationPE-IsolierungCopper conductorKupferleiter AWG 23 AWG 23PP foilApplicationThe FutureCom StarQuad ViMF cable is designed forapplications in industrial and other harsh environments upto 300 MHz and its transmission characteristics satisfyCategory 5 specifications according to ISO/IEC 11801 (2002)and EN 50173-1 (2003).FutureCom ViMF cables are zero-skew products, i.e. the skewbetween the individual pairs of foursomes is very low. This isincreasingly required for Gigabit-Ethernet.StarQuad ViMF cables are intended for multimedia applications(voice, image and data communications) where cablesharing is an option. Alongside traditional applications(ISDN, Ethernet and Token Ring), the cables are suitable forhigh frequency transmissions, such as TPDDI via copper(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to1000 Base-T.FeaturesU/FTP 300/23 cable, specified up to 300 MHzOutstanding electrical characteristicsEach StarQuad (foursome) is shielded (ViMF)Simultaneous, standard-conforming transmissionof multiple services is possibleVery robust, thus particularly suitable for application inindustrial and other harsh environments suitableFull shielding including one PP foil and 2 aluminum-cladfoilsZero skew between the foursomesPVC jacketFlame retardant according to IEC 60332-1, Category BAvailable in 1, 2, 3, and 4 foursomes202 Corning Cable Systems


FutureCom ViMF Cat. 5 Cable (Star Quad)U/FTP 300/23 PVCMechanical CharacteristicsConductor insulationOuter jacketArea/range of applicationTemperature range (installation)Operating temperatureMin. bending radiusfor one-time bendingMin. bending radius duringinstallationCopper conductorHalogen freefoam-skin materialHalogen freeflame retardantDry anddamp rooms0 to +50°C-20 to +60°C1V: >_ 30 mm2V:>_ 30 mm (flat side)3V: >_ 50 mm4V: >_ 52 mm1V: >_ 45 mm2V: >_ 45 mm (flat side)3V: >_ 75 mm4V: >_ 78 mmAWG 23Electrical Characteristics (at 20°C)Largest resistance margin2%Insulation resistance> 5000 M x kmImpedance Zo at 0.064 MHz125 +/- 20%Impedance Zo at 1 - 100 MHz 100 +/- 15%Surface transfer impedance46 dB at 64 kHzdB/BZL = 1000 mUnbalance to ground>40 dB at 1 MHzdB/BZL = 100 mGreatest possible loop resistance 130 /kmOperating capacity48 pF/mPropagation velocity0.68 x cat >10 MHz (NVP x c)Propagation delay >_ 10 MHz4.9 ns/mDelay skew0 ns/100 mFutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionFrequency in MHzAttenuation in dB/100 m *Typical values dB/100mNEXT in dB at 100 m *Typical values in dB at 100 m (pair/pair)Typical values in dB at 100 m (foursome/foursome)PSNEXT in dB at 100 m *Typical values in dB at 100mELFEXT in dB at 100 m *Typical values in dB at 100mPSELFEXT in dB at 100m *Typical values in dB at 100mACR in dB12.11.865.380.090.062.376.763.875.060.873.078.2106.35.250.364.090.047.361.143.864.040.862.058.8168.06.747.261.090.044.257.839.761.036.759.054.3209.07.545.860.090.042.856.937.859.034.857.052.531.2511.49.442.956.090.039.952.833.953.030.951.046.662.516.513.738.450.590.035.447.527.947.024.945.036.810021.317.635.347.090.032.344.023.843.020.841.029.4200–25.1–41.080.0–38.0–32.0–30.015.9300–30.9–38.380.0–35.3–22.0–20.07.4*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)FutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch Cord<strong>Ordering</strong> <strong>Information</strong>Fire Load ZeroType designation Category Quad count (MJ/m) HalogenMaxTensileStrength (N)Outer(mm)Weight(kg/km)Std.Length(m)Order NumberIndustrialCableSpecialCableU/FTP 300/23 1VU/FTP 300/23 2VU/FTP 300/23 3VU/FTP 300/23 4V555512340.651.231.712.00NoNoNoNo551101652205.55.5x9.410.110.4397610512510001000500500CCXSKC-C0012-C001-L7CCXSKC-C0022-C001-L7CCXSKC-C0032-C001-L6CCXSKC-C0042-C001-L6Further<strong>Information</strong>Corning Cable Systems203


204 Corning Cable Systems


Table of contents13 Further <strong>Information</strong>13.1. Training 20613.2. EWP 20713.3. Glossary 20913.4. Type Codes 21113.5. Product Index 212Further<strong>Information</strong>SpecialCableFutureCom 10 TENIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom F IntroductionCorning Cable Systems205


LANscape® TrainingTraining: Expertise for Your EmployeesTotal communication solutions are becoming increasinglyimportant for communication networks, in particular localarea networks (LANs) because the future lies in the convergenceof voice, video and data. Around the globe, as informationinfrastructures evolve, so the demands on the qualityof networked communication solutions continue togrow. Meeting these demands calls for knowledge - knowledgethat we can pass on to you.Techniques and products are subject to constant change.This makes it essential to have highly trained employeeswho know how to exploit technical progress to your advantage.This can only be achieved with continuous training.As a leading provider of communication cables, hardwareand services, we are working with our customers to buildcommunication highways for the future. We realize that theplanning, installation and maintenance of cable systemscalls for comprehensive technical knowledge - somethingwe want to share with you in spirit of genuine partnership.For more <strong>Information</strong> about LANscape® Training:We Train – You BenefitOur worldwide knowledge in cable and network technologyis channeled to our Training Center. It is from this knowledgebase that we develop a wide range of seminars for your employees.Our training is aimed at all organizations involvedin constructing or operating cable systems in the privatenetworks or carrier area. By undertaking training beforestarting on a project, you can avoid costly installation errors,and take a decisive step towards ensuring a successful outcometo your project.Practical Orientation – Not Just TheoryThe balance between the two is critical: theory is necessary,but practice dictates what is done. From many years of practicalexperience, our trainers know which knowledge andskills are required for each task, and they are in constantcontact with development, sales and project engineeringteams at Corning Cable Systems.On the Internet:http://www.corning.com/cablesystemsOr via E-Mail:emea.cs@corning.comOr by phone under:Freephone: 00800 2676 4641Our Training Centers are located in Berlin and Neustadt /Coburg, Germany. Standard and customized courses to meetindividual requirements are held locally throughout theworld, where the technical facilities permit.Detailed training information is available on request.Course Portfolio Private Networks:LANscape® Certified Approved Installer Courses forStructured Premises CablingLANscape® Copper Approved InstallerLANscape® Copper Approved Installer – RefresherLANscape® Fiber Optic Approved InstallerLANscape® Fiber Optic Approved Installer - Refresher206 Corning Cable Systems


LANscape® Cabling Solutions:A Name You Can TrustMeeting and ExceedingGlobal StandardsWe guarantee that each customized Corning Cable SystemsLANscape® Cabling Solution meets or exceeds the globaldata communication and performance standards. You canbe assured that your Corning Cable Systems Solution measuresup to the international cabling requirements,ISO/IEC 11801 and EN 50173 (Europe).Installation Expertise and ReliabilityCorning Cable Systems’ network of LANscape® ExtendedWarranty Program (EWP) installers are carefully selectedand trained.Each partner-company meets our stringent requirements fortechnical experience, financial strength and proven dedicationto quality. EWP partners must demonstrate ongoingcommitment to extensive training and are required toupdate training at least once every two years.LANscape® Solutions Total PackageThe LANscape® end to end product offering is designed todeliver the most technologically advanced communicationssystems to the customer. Corning Cable Systems LANscape®products withstand rigorous field and laboratory testingwith continual design enhancements in response to rapidlyevolving customer environments.Ready for Your Growing NetworkCorning Cable Systems understands the critical need forflexible solutions with the rapid growth of your datacommunications requirements. With Corning Cable Systems’LANscape® Solutions, changes and expansions are costeffectiveand simple. Your cost-of-ownership is minimized!Expert Service and SupportHardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10 TEN FutureCom F IntroductionCorning Cable Systems’ experts support and assist ExtendedWarranty Program installers with the planning, designing,and installing of fiber optic and high-end copper cabling systems..With world-wide distribution channels and a highclass Customer Service Center, Corning Cable Systems makesit easy for EWP installers to quickly get products to your sitefor installation. Highly trained sales consultants located inyour area are available for on-site evaluations and cablingrecommendations.Telephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableFurther<strong>Information</strong>SpecialCableCorning Cable Systems207


LANscape® Solutions:A Name You Can TrustExtended Warranty – Extra ValueCorning Cable Systems’ LANscape® Extended Warrantyprotects your LANscape Fiber Optic and/or High-end CopperSolution for a full 25 years*. The warranty covers total systemperformance as well as each product component of theCorning Cable Systems’ solution. Corning Cable Systemsguarantees to repair or replace defective products for 25years after installation by an EWP Partner. The LANscape®EWP 25-year system warranty is offered when all products inthe cabling solution (cables, connectivity, and interconnectinghardware) are Corning Cable Systems products installedby an EWP Partner.Total Corporate AssuranceCorning Cable Systems is the only company focusing primarilyon fiber cabling solutions while also offering high-endcopper solutions. Our mission is to remain the world’sleading developer and manufacturer of fiber optic andhigh-end copper products for voice, data, and video applications.Corning Cable Systems’ resources for research andproduct development, financial strength, and maturebusiness focus are clearly unmatched in the communicationsindustry.Corning is the inventor of the first commercial optical fibersand the world leader in optical fiber manufacturing for over25 years. Our unique heritage makes Corning Cable Systemsthe one company that can offer a solid corporate foundation,a tradition of quality, and a name you can trust.How You BenefitLANscape® 25 years warrantyInstallation by Corning Cable SystemsApproved partnersPartners trained on the latest technologyCorning Cable Systems total quality*The Extended Warranty of Corning Cable Systems is subject to the terms and conditions set forth in the EWP Contract to be signed by each EWP Partner and setforth in the Warranty Statement granted to the endcustomer of an installation. The liability of Corning Cable Systems for failures /malfunction or alterations ofthe specifications published at the date of installation is repair or replacement of the defective product. Corning Cable Systems shall not be liable for any consequentialdamages or violation of the contract terms with respect to the warranty obligation for this product. The maximum liability of Corning Cable Systemswithin the scope of the Extended Warranty Program is repair and replacement of the Corning Cable Systems product that does not comply with the Corning CableSystems specifications published at the date of installation of such product plus labor costs in connection with the replacement or the repair of such productsamounting to a maximum of Euro 10.000 (ten thousand).208 Corning Cable Systems


GlossaryACRANEXTAttenuationAttenuation constantATMAWGCable coreCable sheathCapacitance unbalanceCharacteristic impedanceConductorConductor resistanceCorrosiveDC loop resistanceDelay skewDielectricELFEXTFEXTFire ratingFlame retardantFrequencyFRNCImpedanceInsulation resistanceAttenuation-to-crosstalk ratioCrosstalk noise from other cables in a bundle of cables or from a second cable unit in a duplexcable.Reduction in electrical signal power between two defined points on a transmission path. It isfrequency dependent and caused mainly by resistance and the skin effect (unit: dB)Known also as attenuation coefficient, it is the length related attenuation introduced by thecable in the stationary condition (unit: dB/km or dB/100m).Asynchronous Transfer Mode is a network technology based on transferring data in cells orpackets of fixed size. ATM supports data transfer rates of from 25 to 622 Mbps (megabits persecond).American designation for conductor diameter (American Wire Gauge)The totality of cabling elements in the cable and the wrapping covering all these elements.Covering, generally of polyethylene (PE), polyvinylchloride (PVC) or zero-halogen material (H),to protect the cable core against environmental influences.The difference between the ground capacitances of the two conductors.Complex quantity defining the ratio of voltages to currents in a propagating wave at everypoint along the line.The conductor is used for transporting the electrical charge carriers and is therefore made ofelectrically conducting material (metal). The conductor is usually round.Conductor resistance is determined by the quality of the copper used and the cross-section ofthe conductor. It increases linearly with cable length and has a determining influence on theattenuation.Release of corrosive gases and acids by the combustion of cables and lines. For indoor installations,non-corrosive cables should be used. Halogen-free cables are generally non corrosive.Overall DC resistance of the go and return conductors (unit: ?/km)The difference in time between the arrival (reception) of a data signal and subsequent relateddata signals. Usually expressed in nanoseconds.Insulating material, also termed dielectric medium, i.e. an electrically non-conducting materialA measurement of the unwanted signal coupling from a transmitter at the near end into anotherpair, measured at the far end with the effects of the attenuation removed.Far-end crosstalk loss is the attenuation between the transmission circuits of a cable at thedifferent ends of the cable.Sum of the combustion heat of all the combustible materials located in a room (unit for cables:MJ/m)Description of the behavior of products with respect to fire propagation. Enhanced flameretardancy is generally required only for indoor cables.Number of complete cycles per second (in Hz).Flame retardant (FR) and non corrosive (NC)Impedance of an electrical four-terminal network. It comprises the DC resistance and thereactance, the latter being the frequency-dependent opposition to current flow offered byinductances and capacitances. Impedance is physically determined by the dimensions of innerconductor, dielectric and shield.This is determined by the insulating material and more particularly by the nature of theinsulant than by its thickness. The insulation resistance is length dependent.FutureCom F IntroductionFutureCom 10 TENFutureCom EFutureCom DFutureCom UEFutureCom UDHardwareTelephone /ISDN ProductsFlex Wire Cablefor Patch CordIndustrialCableSpecialCableFurther<strong>Information</strong>Corning Cable Systems209


GlossaryLAN: Local Area Network Local network for bit-serial transmission between interconnected, independent terminalequipments. The term LAN was introduced in order to distinguish this network from processorlinks (central processor unit with peripherals) operating at very high bit rates over shortdistances on the one hand and from publicly accessible networks operating over longdistances on the other.Length of layThe distance along the center axis of a cable that a cabling element advances in order tocomplete one full turn (360°) about this axis.LS0H/LSZHLow smoke (LS) and zero halogen (0H)Mutual capacitance Effective capacitance of the lineNEXTNear-end crosstalk loss is the attenuation between the transmission circuits of a cable at thesame end of the cable.Propagation delayThe time required for a signal to pass along a transmission line.Propagation velocity The velocity of wave propagation along a transmission line.PS-ACRThe difference between attenuation and PSNEXT. The result is referred to as “head room”. Themore head room a cable or system has the more forgiving it will be with the installation errors(apart from mis-wiring).PSANEXTSum of the unwanted signal coupling of crosstalk noise at the near end from external cablingpairs into an affected pair of cable.PSELFEXTA computed sum value of the individual ELFEXT effects on each pair by the other 3 pairs.ELFEXT removes the impact of insertion loss on Far End Crosstalk.PSNEXTThe sum of all pair combinations for crosstalk as it occurs when a signal is introduced into acommunications cable, and measured at the near end to the transmitterQuadA series of four separately insulated conductors, generally twisted together.Resistance unbalance Difference in DC resistance between two wires of a circuit (unit: ?)Return lossThe difference between the power incident upon a discontinuity in a transmission system andthe power reflected from the discontinuity.ShieldStructural cable element for shielding. The design of the shield depends on whether one isseeking protection against electric fields (capacitive coupling) or magnetic fields (inductivecoupling) or against both. Shielding materials against magnetic fields should always have ahigh electrical conductivity and small inductance, which is why, in the case of conductors,copper is mostly used.ShieldingProtects against electric and magnetic influence caused by emission (emitted interference)and emission (received interference).SkewA measure of the inequality of propagation delay between two pairs in a multi-pair cableSkin effectTendency for higher frequency currents to travel near the outside surface of a conductorSmoke densityMeasure of the smoke generated by a burning cable. For indoor installation, cables should beselected with a low smoke density (typical value: 50%).Transfer impedance Surface transfer impedance is a measure of the effectiveness of the shielding and is defined asthe ratio of the voltage along the shield of the disturbed system to the current in thedisturbing system.Twisted pairA transmission line in which two insulated conductors are twisted together.WireThe wire is a conductor with a surrounding insulant. The insulant can be air or otherelectrically non-conducting material (usually plastic).210 Corning Cable Systems


Type Codes for Copper CablesFurther<strong>Information</strong>SpecialCableIndustrialCableFlex Wire Cablefor Patch CordTelephone /ISDN ProductsHardwareFutureCom UDFutureCom UEFutureCom DFutureCom EFutureCom 10 TENFutureCom F IntroductionCorning Cable Systems211